1. Entwodiksyon
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Danfoss KP1 Pressure Switch, model 060-110166. The KP1 pressure switch is designed for use in refrigeration and air conditioning systems to protect against excessively low suction pressure or excessively high discharge pressure. It features a regulation range of -0.20 to 7.50 Bar and a 1/4 inch flare connection.
Please read this manual thoroughly before installing or operating the device to ensure proper function and to prevent potential hazards.
2. Enfòmasyon sou Sekirite
WARNING: Improper installation, operation, or maintenance can result in serious injury or equipment damage.
- Always disconnect power before performing any installation, maintenance, or service on the pressure switch.
- Installation and service must be performed by qualified personnel only, in accordance with all local and national electrical and refrigeration codes.
- Ensure the system pressure is relieved before disconnecting the pressure switch from the refrigeration system.
- Mete ekipman pwoteksyon pèsonèl (PPE) ki apwopriye pandan enstalasyon ak sèvis.
- Do not exceed the maximum rated pressure or electrical load specified for the device.
3. Pwodwi souview
The Danfoss KP1 Pressure Switch is a compact, robust, and reliable control device. It is equipped with a single-pole double-throw (SPDT) contact system, allowing for flexible control applications. The switch is designed for direct mounting on the refrigeration system.
Karakteristik kle:
- Wide pressure regulation range: -0.20 to 7.50 Bar.
- Differential pressure adjustment.
- 1/4 inch flare connection for easy installation.
- IP54 enclosure rating for protection against dust and splashing water.
- Automatic operation mode.
Eleman:
Refer to the image below for a visual representation of the Danfoss KP1 Pressure Switch.

Figi 1: Devan view of the Danfoss KP1 Pressure Switch, showing the Danfoss logo and the rating plate.
4. Enstalasyon ak Enstalasyon
Careful installation is crucial for the correct function and longevity of the pressure switch.
4.1 Montaj
The KP1 pressure switch is designed for panel mounting. Ensure a stable and vibration-free location. The switch should be mounted vertically with the pressure connection facing downwards to prevent accumulation of oil or moisture in the pressure element.
4.2 Koneksyon Presyon
The pressure switch features a 1/4 inch flare connection. Use appropriate tools and ensure a leak-tight connection to the refrigeration system.

Figure 2: Danfoss KP1 Pressure Switch with its 1/4 inch flare connection components disassembled, showing the nut and adapter.

Figi 3: Anba view of the Danfoss KP1 Pressure Switch, highlighting the 1/4 inch flare connection point.
- Ensure the system is depressurized before connecting the switch.
- Apply a small amount of refrigeration oil to the flare connection threads.
- Tighten the flare nut securely using a flare nut wrench to prevent leaks. Do not overtighten.
- Fè yon tès flit apre koneksyon an.
4.3 Fil elektrik
The KP1 pressure switch has SPDT (Single-Pole Double-Throw) contacts. Refer to the wiring diagram provided with the product or on the inside of the cover for specific connections. Ensure all wiring complies with local electrical codes.
- Connect the common terminal (C) to the power source.
- Connect the normally open (NO) terminal for circuits that should close on pressure rise (e.g., high-pressure cut-out).
- Connect the normally closed (NC) terminal for circuits that should open on pressure rise (e.g., low-pressure cut-in).
- Asire bon baz.
5. Operasyon Enstriksyon
The Danfoss KP1 Pressure Switch allows for adjustment of both the cut-in pressure and the differential pressure.
5.1 Setting the Cut-in Pressure
The cut-in pressure (or cut-out pressure, depending on application) is set using the main adjustment screw. This screw typically adjusts the spring tension, which determines the pressure at which the switch changes state.
- Remove the protective cover of the switch.
- Locate the main adjustment screw (often labeled 'RANGE' or 'CUT IN').
- Turn the screw clockwise to increase the set pressure, and counter-clockwise to decrease it.
- Use a pressure gauge to monitor the system pressure and verify the setting.
5.2 Setting the Differential Pressure
The differential pressure determines the difference between the cut-in and cut-out pressures. This is crucial for preventing rapid cycling of the compressor.

Figi 4: Entèn view of the Danfoss KP1 Pressure Switch with the cover removed, showing the adjustment dials for 'CUT IN' (range) and 'DIFF' (differential).
- Locate the differential adjustment screw (often labeled 'DIFF').
- Turn the screw clockwise to increase the differential, and counter-clockwise to decrease it.
- The cut-out pressure will be the cut-in pressure minus the differential (for low-pressure switches) or the cut-in pressure plus the differential (for high-pressure switches).
- Replace the protective cover after adjustments are complete.
6. Antretyen
The Danfoss KP1 Pressure Switch is designed for long-term, reliable operation with minimal maintenance. However, periodic checks are recommended.
- Enspeksyon vizyèl: Enspekte switch la regilyèman pou nenpòt siy domaj fizik, korozyon, oswa koneksyon ki lach.
- Deteksyon koule: Periodically check the pressure connection for refrigerant leaks using an appropriate leak detector.
- Tcheke fonksyonèl: If possible and safe to do so, periodically verify the switch's set points by observing system pressure and switch operation.
- Netwayaj: Kenbe deyò switch la pwòp epi san pousyè ak debri. Pa sèvi ak pwodui chimik ki agresif.
Note: Internal components are not user-serviceable. Do not attempt to disassemble the sealed unit beyond removing the cover for adjustments.
NAN. Depanaj
This section provides guidance on common issues you might encounter with the KP1 Pressure Switch.
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Switch does not activate at set pressure. | Incorrect setting, faulty wiring, pressure connection leak, internal fault. | Verify settings, check wiring continuity, inspect for leaks, replace switch if faulty. |
| System cycles too frequently. | Differential setting too low, system issues (e.g., low refrigerant charge). | Increase differential setting, diagnose and rectify system issues. |
| Switch contacts remain open/closed. | Pressure outside operating range, stuck contacts, internal fault. | Check system pressure, replace switch if contacts are stuck or internal fault is suspected. |
| Refrigerant leak at connection. | Improperly tightened flare nut, damaged flare, worn gasket. | Retighten connection, inspect flare for damage, replace gasket if present, ensure proper torque. |
If troubleshooting steps do not resolve the issue, contact a qualified service technician or Danfoss support.
8. Espesifikasyon
The following table outlines the technical specifications for the Danfoss KP1 Pressure Switch (Model 060-110166):
| Spesifikasyon | Valè |
|---|---|
| Nimewo Modèl | 060-110166 |
| Mak | Danfoss |
| Règleman Range | -0.20 to 7.50 BAR |
| Kalite Koneksyon | 1/4 Inch Flare |
| Mòd operasyon | Otomatik |
| Kalite kontak | Nòmalman Ouvè (SPDT) |
| Kalite Awondisman | 2-fason |
| Kalite aliye | Panel Mount |
| Kontakte Materyèl | Kwiv |
| Rating Pwoteksyon Entènasyonal | IP54 |
| Dimansyon pake | 5.11 x 3.54 x 1.58 pous |
| Pwa atik | 1.1 liv |
9. Garanti ak sipò
Danfoss products are manufactured to high-quality standards. For specific warranty information, please refer to the documentation provided with your purchase or visit the official Danfoss website. For technical support, service, or spare parts, please contact your authorized Danfoss distributor or a qualified service technician.
Protection plans may be available for extended coverage. Please check with your retailer for details on available protection plans.