Digitus DN-91624S-EA

Manyèl Enstriksyon Digitus Cat-6A 24-Pò Patch Panel Pwoteje (DN-91624S-EA)

Model: DN-91624S-EA

1. Entwodiksyon

This manual provides detailed instructions for the installation, operation, and maintenance of your Digitus Cat-6A 24-Port Shielded Patch Panel, model DN-91624S-EA. This patch panel is designed for efficient cable management and reliable network connectivity in 19-inch rack environments, supporting high-speed data transmission up to 10 Gigabit Ethernet (10GBase-T) and Power over Ethernet (PoE+) applications.

2. Enfòmasyon sou Sekirite

3. Pake kontni

Verifye ke tout atik yo prezan nan pakè a:

4. Pwodwi souview

The Digitus Cat-6A 24-Port Shielded Patch Panel features 24 RJ45 ports on the front for connecting network devices via patch cables, and LSA (LSA-Plus) termination blocks on the rear for permanent cable installation. The panel is designed for 1U rack mounting and provides robust shielding for enhanced signal integrity.

Devan view of the Digitus Cat-6A 24-Port Shielded Patch Panel

Figi 4.1: Devan view of the Digitus Cat-6A 24-Port Shielded Patch Panel, showing 24 numbered RJ45 ports and the Cat.6A label.

Dèyè view of a patch panel showing LSA termination blocks

Figi 4.2: Dèyè view of a patch panel (illustrative, white variant shown) displaying the LSA termination blocks for connecting network cables.

5. Enstalasyon

5.1. Montaj etajè

  1. Identify an available 1U (1.75 inches) space in your standard 19-inch network or server cabinet.
  2. Align the mounting ears of the patch panel with the rack rails.
  3. Secure the patch panel to the rack using the provided mounting screws. Ensure it is firmly attached.

5.2. Cable Termination (LSA Strips)

The patch panel uses LSA (LSA-Plus) termination blocks, color-coded according to EIA/TIA 568 A and B standards. Ensure you consistently use either standard A or standard B for all connections within your network.

Close-up of LSA termination blocks with terminated network cables

Figi 5.1: Close-up view of LSA termination blocks (illustrative, white variant shown) with network cables properly terminated and secured.

  1. Prepare your Cat-6A network cables by stripping approximately 1-2 inches of the outer jacket, exposing the twisted pairs. Be careful not to damage the wire insulation.
  2. Untwist the pairs minimally, just enough to separate the individual wires.
  3. Refer to the color coding diagram on the LSA block (EIA/TIA 568 A or B).
  4. Place each individual wire into its corresponding slot on the LSA block.
  5. Use an LSA punch-down tool to firmly press each wire into its slot. The tool will simultaneously cut off any excess wire.
  6. Repeat this process for all 24 ports.
  7. After termination, use the provided cable ties to secure the installed cables to the cable management bar at the rear of the patch panel, reducing strain on the LSA connections.
  8. Ensure proper grounding of the patch panel to the rack for optimal shielding.

6. Operasyon Enstriksyon

Once the network cables are terminated on the rear LSA blocks, the patch panel is ready for operation.

  1. Connect standard RJ45 patch cables from your network devices (e.g., computers, servers, switches) to the front RJ45 ports of the patch panel.
  2. Ensure the patch cables are fully inserted and click into place.
  3. The patch panel facilitates organized connections between your network infrastructure and end devices.
Close-up of RJ45 ports with red patch cables connected

Figi 6.1: Close-up view of RJ45 ports (illustrative, white variant shown) with red patch cables connected, demonstrating active network connections.

7. Antretyen

NAN. Depanaj

If you encounter issues with your network connections through the patch panel, consider the following:

PwoblèmKòz posibSolisyon
Pa gen koneksyon rezoLoose patch cable connection
Incorrect LSA termination
Faulty patch cable
Ensure patch cables are fully seated
Verify LSA terminations using a cable tester and re-terminate if necessary
Test with a known good patch cable
Ralanti vitès rezo aPoor quality patch cable
Improper Cat-6A termination
Interference (lack of proper shielding)
Use certified Cat-6A patch cables
Ensure LSA terminations follow EIA/TIA 568 A/B standards precisely
Verify patch panel and cables are properly shielded and grounded
Koneksyon tanzantanKab domaje
Loose LSA termination
Pwoblèm konektè
Enspekte epi ranplase kab ki domaje yo
Re-punch loose LSA connections
Check RJ45 ports for damage

9. Espesifikasyon

KarakteristikDetay
Nimewo ModèlDN-91624S-EA
Pwopriyete transmisyonCategory 6A, Class EA
Zòn aplikasyonUp to 500 MHz, 10GBase-T
Norms ComplianceISO/IEC 11801 2nd Ed., EN 50173-1, EIA/TIA 568-C, 802.3af, 802.3at PoE+
Montaj483 mm (19") cabinet mounting, 1U height
Enstalasyon kabLSA strips, color coded according to EIA/TIA 568 A & B
Kalite ConnectorRJ45
Dimansyon (L x W x H)19.02 x 4.33 x 1.77 pous (apeprè)
Pwa3.24 liv (apeprè)

10. Garanti ak sipò

Digitus products are manufactured to high-quality standards and are backed by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Digitus website. For technical support or assistance, please contact your local Digitus distributor or reseller.

For further information, you may visit the Digitus websit: www.digitus.info

Dokiman ki gen rapò - DN-91624S-EA

Preview Gid Enstalasyon Panèl Patch Pwoteje DIGITUS
Gid enstalasyon konplè pou panèl koneksyon DIGITUS ki pwoteje, ki kouvri soulajman tansyon, fiksasyon kab, ak pwosedi koneksyon. Gen ladan espesifikasyon pwodwi ak enfòmasyon konfòmite RoHS.
Preview Manyèl Itilizatè Switch PoE Konbine DIGITUS 16/24FE (PoE) + 2G
Manyèl itilizatè pou switch DIGITUS 16/24FE (PoE) + 2G Combo PoE (DN-95342 Rev.2, DN-95343 Rev.2), ki detaye karakteristik, pyès ki nan konpitè, enstalasyon, ak espesifikasyon pou koneksyon rezo a.
Preview Manyèl Itilizatè Switch DIGITUS 8-Pò Jere Gigabit Ethernet | DN-651123, DN-651125
Manyèl itilizatè konplè pou switch DIGITUS 8-Port Managed Gigabit Ethernet Switch (modèl DN-651123 ak DN-651125). Aprann plis sou karakteristik pwodwi a, espesifikasyon yo, enstalasyon an, ak konfigirasyon rezo a.
Preview DIGITUS Field Termination Coupler CAT 6A, 500 MHz Installation Guide
Step-by-step installation guide for the DIGITUS Field Termination Coupler CAT 6A, 500 MHz (DN-93912), including stripping, wire management, and final assembly.
Preview Gid Enstalasyon Rapid pou Lojman Miray DIGITUS SOHO PRO Seri a
Enstriksyon detaye pou enstale kabinèt rezo DIGITUS Wall Housing SOHO PRO Series yo, ki gen ladan modèl DN-49100 jiska DN-49105.
Preview DIGITUS 4-pò switch Ethernet endistriyèl rapid - Gid Sekirite ak Operasyon
Nòt sekirite esansyèl ak enstriksyon fonksyònman pou switch rezo Ethernet rapid 4 pò DIGITUS la (DN-651130), yon switch endistriyèl, ki pa jere ak 1 SFP FE uplink.