1. Entwodiksyon
The Elitech ECS-02CX is a versatile digital temperature controller designed for precise temperature management in various applications, including refrigeration, coolrooms, and heating equipment. Featuring a clear red/blue LED display and intuitive controls, it offers reliable performance for maintaining desired temperature ranges. This manual provides essential information for the safe and effective installation, operation, and maintenance of your ECS-02CX controller.
2. Enfòmasyon sou Sekirite
Please read all safety warnings and instructions carefully before installing or operating the device. Failure to do so may result in electric shock, fire, or damage to the product.
- Asire w ke ekipman pou kouran an dekonekte anvan ou fè nenpòt fil elektrik oswa antretyen.
- Installation and wiring should only be performed by qualified personnel.
- Pa ekspoze aparèy la nan dlo oswa imidite twòp.
- Verifye tout koneksyon yo byen fèm epi kòrèk anvan ou mete kouran an.
- The compressor relay is rated for up to 30A, capable of directly driving a 1.5HP single-phase compressor. Ensure connected loads do not exceed this rating.
3. Pwodwi souview
The Elitech ECS-02CX features a compact design with a clear digital display and user-friendly buttons for easy parameter setting. It includes dual-way sensor inputs for both cabinet temperature and defrost sensing.


4. Enstalasyon
Proper installation is crucial for the correct functioning and longevity of the ECS-02CX controller. Follow these steps carefully.
4.1 Montaj
The controller is designed for panel mounting. Ensure adequate space for ventilation and wiring connections. Secure the controller using the provided mounting clips.
4.2 Dyagram fil elektrik
Refer to the wiring diagrams below for correct electrical connections. Ensure all wires are properly insulated and secured.


Koneksyon tèminal:
- Tèminal 1 ak 2: Room Temperature Sensor input.
- Tèminal 3 ak 4: Evaporator (Defrost) Sensor input.
- Tèminal 6 ak 7: Power Supply (220VAC, 50/60Hz).
- Tèminal 8: Line input for compressor relay.
- Tèminal 9: Pwodiksyon COMPRESSOR.
5. Operasyon
The ECS-02CX features a user-friendly interface for setting and monitoring temperature parameters.
5.1 Montre
The controller features a red/blue LED display that shows the current temperature and various parameter settings. The display area is designed for clear and intuitive readability.
5.2 Anviwònman debaz yo
To access and modify parameters, typically press and hold the 'Set' button. Use the Up and Down arrow buttons to navigate through parameters and adjust values. Press 'Set' again to confirm and save changes.
Specific parameter codes and their functions are detailed in the full product manual provided by Elitech. Common parameters include setpoint temperature, differential, defrost cycle settings, and sensor calibration.
6. Antretyen
Regular maintenance ensures optimal performance and extends the lifespan of your ECS-02CX controller.
- Netwayaj: Siye ekran an epi casinSiye ak yon twal mou epi sèk. Pa sèvi ak pwodui netwayaj abrazif oswa solvan.
- Koneksyon: Tcheke tout koneksyon fil elektrik yo detanzantan pou asire yo byen fèm epi yo pa gen korozyon.
- Detèktè: Ensure temperature sensors are clean and properly positioned for accurate readings.
- Vantilasyon: Ensure the controller has adequate ventilation to prevent overheating.
NAN. Depanaj
If you encounter issues with your ECS-02CX controller, refer to the following common problems and solutions.
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Ekspozisyon an vid | Pa gen kouran, fil elektrik yo pa kòrèk, oswa yon pwoblèm entèn. | Check power supply and wiring connections. If problem persists, contact support. |
| Lekti tanperati a pa kòrèk | Sensor fault, incorrect sensor placement, or calibration issue. | Check sensor connections and placement. Refer to the full manual for sensor calibration. Replace sensor if damaged. |
| Compressor not turning on/off | Incorrect setpoint/differential, wiring error, or relay fault. | Verify setpoint and differential settings. Check compressor wiring. Ensure load does not exceed relay capacity. |
| Kòd erè parèt | Defo sistèm espesifik. | Refer to the Elitech ECS-02CX full user manual for a list of error codes and their corresponding solutions. |
If you cannot resolve the issue using the information above, please contact Elitech customer support.
8. Espesifikasyon
Detailed technical specifications for the Elitech ECS-02CX Digital Temperature Controller.
| Karakteristik | Spesifikasyon |
|---|---|
| Modèl | ECS-02CX |
| Manifakti | Elitech |
| Style | Digital |
| Kalite ekspozisyon | Digital (Red/Blue LED) |
| Antre Capteur | Dual-way (Cabinet Temperature, Defrost) |
| Relè Compressor | 30A (capable of driving 1.5HP single-phase compressor) |
| Itilizasyon tipik | Refrigerators, Coolrooms, Freezers, Heating Equipment |
| Pwa atik | 500 Gram (0.5 Kilogram) |
| Premye Dat ki disponib | 23 mas 2018 |
9. Garanti ak sipò
For warranty information and technical support, please refer to the official Elitech websit la oubyen kontakte sèvis kliyan Elitech dirèkteman. Kenbe resi acha ou kòm prèv acha pou reklamasyon garanti.
Elitech Contact Information: Please visit the official Elitech websit la pou jwenn dènye enfòmasyon kontak ak resous sipò yo.