OSRAM EN-RPA2RNE-120-347

OSRAM Encelium EN-RPA2RNE-120-347 Lighting Control Panel User Manual

Model: EN-RPA2RNE-120-347

1. Entwodiksyon

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the OSRAM Encelium EN-RPA2RNE-120-347 Lighting Control Panel. This device is designed to integrate into Encelium Lighting Control Systems, offering robust control over lighting circuits.

The EN-RPA2RNE-120-347 is a 2-relay panel compatible with 120V to 347V electrical systems, providing flexible application in various commercial and industrial lighting environments.

2. Enfòmasyon sou Sekirite

Tanpri li epi konprann tout enstriksyon sekirite yo anvan ou enstale oswa itilize pwodui sa a. Si ou pa swiv enstriksyon sa yo, sa ka lakòz chòk elektrik, dife oswa blesi grav.

  • Se sèlman pèsonèl kalifye ki dwe fè enstalasyon ak antretyen.
  • Disconnect power at the circuit breaker or fuse box before installing or servicing the unit.
  • Asire w ke tout fil elektrik yo konfòm ak kòd elektrik nasyonal ak lokal yo.
  • Pa sèvi ak aparèy la si li sanble domaje.
  • Pwodwi sa a fèt pou itilize andedan kay la sèlman.

3. Pake kontni

Verifye ke tout konpozan yo prezan anvan ou kòmanse enstalasyon an:

  • OSRAM Encelium EN-RPA2RNE-120-347 Lighting Control Panel (1 unit)
  • Gid enstalasyon (dokiman sa a)
  • Mounting hardware (screws, anchors - may vary)

4. Pwodwi souview

The OSRAM Encelium EN-RPA2RNE-120-347 is a black-finished control panel designed for robust lighting management. It features two independent relays for switching lighting loads.

OSRAM Encelium EN-RPA2RNE-120-347 Lighting Control Panel, closed view

Figi 1: Ekstèn view of the OSRAM Encelium EN-RPA2RNE-120-347 Lighting Control Panel. The panel features a secure, lockable door for protection of internal components.

OSRAM Encelium EN-RPA2RNE-120-347 Lighting Control Panel, internal view

Figi 2: Entèn view of the OSRAM Encelium EN-RPA2RNE-120-347 Lighting Control Panel. This view shows the internal wiring, two relay modules, and the transformer, indicating the robust construction for electrical control.

5. Enstalasyon ak Enstalasyon

5.1 Lis Enstriksyon Pre-Enstalasyon an

  • Ensure power is disconnected at the main breaker.
  • Verify the installation location is suitable (dry, protected, adequate space).
  • Konfime voltage konpatibilite (120V-347V).

5.2 Monte Panel la

  1. Select a secure, flat surface for mounting.
  2. Mark the desired mounting points using the panel as a template.
  3. Drill pilot holes if necessary and secure the panel using appropriate mounting hardware.

5.3 Enstriksyon fil elektrik

All wiring must be performed by a licensed electrician in accordance with all applicable electrical codes.

  1. Route power supply wires (120V-347V) to the panel.
  2. Connect the incoming power to the designated terminals within the panel.
  3. Connect the lighting load wires to the respective relay output terminals. Each relay controls one circuit.
  4. Asire w ke tout koneksyon yo sere epi an sekirite.
  5. Close and secure the panel door.

5.4 Premye pouvwa-up

After installation and wiring are complete, restore power at the main circuit breaker. Observe the panel for any indicator lights or initial system responses.

6. Operasyon Enstriksyon

The OSRAM Encelium EN-RPA2RNE-120-347 Lighting Control Panel functions as a component within a larger Encelium Lighting Control System. Direct user interaction with the panel itself is typically limited to status indication and maintenance access.

  • Entegrasyon sistèm: The panel communicates with the Encelium system controller to receive commands for switching the connected lighting loads.
  • Relay Functionality: Each of the two relays can be independently controlled by the Encelium system to turn connected lighting circuits ON or OFF.
  • Endikatè Status: Refer to the Encelium system documentation for interpretation of any status LEDs or indicators on the panel, which typically show power status and relay state.

For detailed programming and scheduling of lighting events, refer to the specific user manual for your Encelium system controller.

7. Antretyen

The OSRAM Encelium EN-RPA2RNE-120-347 Lighting Control Panel requires minimal maintenance to ensure optimal performance.

  • Netwayaj: Periodically wipe the exterior of the panel with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure power is off before cleaning.
  • Enspeksyon: Annually, or as required by local codes, have a qualified electrician inspect the panel for any signs of wear, loose connections, or damage.
  • Pa gen okenn pati itilizatè yo ka fè sèvis: There are no user-serviceable parts inside the panel. Any internal servicing must be performed by authorized personnel.

NAN. Depanaj

If you experience issues with your lighting control panel, refer to the following basic troubleshooting steps. For complex issues, contact technical support.

  • Pa gen kouran nan panèl la:
    • Check the main circuit breaker for the panel's power supply.
    • Verify all power connections within the panel are secure (only by qualified personnel).
  • Relays Not Responding:
    • Ensure the Encelium system controller is operational and communicating with the panel.
    • Check the wiring from the relays to the lighting loads.
    • Consult the Encelium system manual for diagnostic information.
  • Unexpected Lighting Behavior:
    • Review the programming and schedules within your Encelium system.
    • Verify that the correct lighting loads are connected to the intended relays.

If problems persist, contact OSRAM technical support.

9. Espesifikasyon

AtribiDetay
ManifaktiOSRAM
Nimewo PatiEN-RPA2RNE-120-347
Pwa atik30 liv
Dimansyon pwodwi22 x 21 x 8 pous
KoulèNwa
FiniNwa
Sous pouvwaFil elektrik
Voltage120 - 347 Vòlt
Kantite pake atik1
Kantite moso1
Premye Dat ki disponib1 janvye 2014

10. Garanti ak sipò

This OSRAM product is covered by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official OSRAM websit.

For technical support, troubleshooting assistance, or warranty claims, please contact OSRAM customer service. You can find contact information on the official OSRAM websit la oubyen atravè founisè pwodwi ou a.

OSRAM Official Websit: www.osram.com

Dokiman ki gen rapò - EN-RPA2RNE-120-347

Preview OSRAM Wireless Area Lighting Control Module (WALC) Wiring and Installation Manual
Detailed wiring and installation guide for the OSRAM Wireless Area Lighting Control Module (WALC), covering setup, configurations, safety precautions, and regulatory information for the ENCELIUM® Networked Light Management System.
Preview Manyèl Fil elektrik ak Enstalasyon Estasyon Miray San Fil OSRAM
Gid konplè pou enstalasyon ak fil elektrik estasyon miray san fil OSRAM yo, ki prezante konpatibilite ENCELIUM, operasyon pil, ak enstriksyon enstalasyon pou divès bwat aparèy ak plak dekoratif.
Preview Modil Kontwòl Ekleraj Zòn San Fil OSRAM (WALC) EN-ALC-ZB-BK Fich Done ak Gid Enstalasyon
Fich done konplè ak gid enstalasyon pou Modil Kontwòl Ekleraj Zòn San Fil OSRAM (WALC) modèl EN-ALC-ZB-BK la. Li gen kontwòl san fil ZigBee®, gradyasyon 0-10V, kapasite chaj 20A, ak konpatibilite ak sistèm ENCELIUM® yo.
Preview Gid Enstalasyon ak Enfòmasyon sou Pwodwi pou Capteur Okipasyon OSRAM ENCELIUM
Enstriksyon konplè pou enstalasyon, karakteristik, operasyon, ak depanaj pou detektè okipasyon ak pake pouvwa OSRAM ENCELIUM, ki gen ladan modèl ki monte sou miray, ki monte sou plafon, ak ki gen switch.
Preview Detektè Okipasyon ENCELIUM ki Monte nan Plafon: Karakteristik, Espesifikasyon, ak Enstalasyon
Enfòmasyon detaye sou detektè okipasyon ENCELIUM ki monte nan plafon an, ki gen ladan modèl enfrawouj pasif (PIR) ak ultrasonik (U/S). Li kouvri karakteristik, benefis, aplikasyon, enfòmasyon sou kòmand, espesifikasyon teknik, dyagram fil elektrik, enstalasyon ak garanti.
Preview OSRAM LED Worklight Panel 50W 840: Technical Specifications, Features, and Safety
Explore the OSRAM LED Worklight Panel 50W 840. This document details its technical specifications, including IP ratings (IP54, IP44, IP65), lumen output, color temperature, dimensions, weight, energy efficiency class (F), and important safety and usage guidelines.