AMS 405.57

Manyèl Itilizatè Revètman Aliminyòm AMS 405.57 1 1/2" x 12"

Model: 405.57 | Brand: AMS

Entwodiksyon

This manual provides essential information for the proper use, maintenance, and care of your AMS 405.57 1 1/2" x 12" Aluminum Liner. This liner is designed for use with various 1-1/2" AMS core samplers, facilitating efficient and reliable sample koleksyon.

Pwodwi souview

AMS 1 1/2 inch by 12 inch aluminum liner

Deskripsyon imaj: A single, cylindrical aluminum tube, approximately 12 inches in length, with an outer diameter of 1 1/2 inches. The surface appears brushed or slightly textured, indicative of aluminum material. Both ends are open, showing the hollow interior of the liner. This image illustrates the primary component of the AMS 405.57 product.

The AMS 405.57 Aluminum Liner is a precision-engineered component for soil and sediment sampling. It features a 1-1/2 inch outer diameter and a 12-inch length. The wall thickness is approximately 0.060 inches, providing a balance of durability and lightweight handling. This liner is specifically designed to integrate seamlessly with compatible AMS core samplers.

Karakteristik kle:

Enstalasyon

Before using the aluminum liner, ensure you have the appropriate AMS core sampler that is compatible with a 1-1/2 inch liner. The liner is intended to be inserted into the core sampler barrel to collect and retain soil or sediment samples.

  1. Inspect the Liner: Carefully examine the aluminum liner for any signs of damage, dents, or deformities that could affect its performance or fit within the core sampler.
  2. Clean the Liner: Ensure the interior and exterior of the liner are clean and free from debris, dirt, or residues from previous uses. Use a soft cloth and mild detergent if necessary, then rinse thoroughly and dry completely.
  3. Prepare Core Sampler: Refer to your AMS core sampler's manual for specific instructions on preparing it for liner insertion. Ensure the sampler barrel is clean and free of obstructions.
  4. Mete revètman: Gently slide the aluminum liner into the designated slot or barrel of your 1-1/2" AMS core sampler. Ensure it seats properly and securely. Do not force the liner, as this could cause damage to either the liner or the sampler.
  5. Verifye anfòm: Once inserted, confirm that the liner is flush and stable within the core sampler, ready for sampling operasyon yo.

Enstriksyon Operasyon

The aluminum liner functions as a disposable or reusable sleeve within a core sampler to preserve the integrity of collected samples. Its operation is directly tied to the use of the core sampler itself.

  1. Attach Core Sampler: Assemble your AMS core sampler with the aluminum liner installed, following the sampler's specific instructions.
  2. Fè Sampling: Use the core sampler as directed by its manual to collect the desired soil or sediment sample. The liner will fill with the sample as the sampler penetrates the ground.
  3. Retrieve Sampler: Carefully extract the core sampler from the ground.
  4. Retire revètman an: Once the core sampler is retrieved, gently remove the aluminum liner containing the sample. This may involve detaching the sampler's cutting tip or other components as per your sampler's design.
  5. Seal Sample: Si sample is to be transported or stored, cap both ends of the liner immediately to prevent sample loss, contamination, or disturbance. Use appropriate end caps or sealing methods.
  6. Label Liner: Clearly label the liner with all necessary sample identification information (e.g., date, time, location, depth, project ID).

Nòt: Always refer to the specific operating instructions of your AMS core sampler for detailed sampling procedures. The aluminum liner is a passive component designed to hold the sample.

Antretyen

Proper maintenance extends the life of your aluminum liner, especially if intended for multiple uses, and ensures sample entegrite.

Depanaj

This section addresses common issues that may arise during the use of your aluminum liner.

PwoblèmKòz posibSolisyon
Liner does not fit into core sampler.
  • Incorrect liner size.
  • Liner is dented or deformed.
  • Core sampler barrel is obstructed or damaged.
  • Verify liner dimensions (1 1/2" OD) against sampler specifications.
  • Inspect liner for damage; replace if necessary.
  • Clean and inspect core sampler barrel.
Sample is difficult to extract from liner.
  • Compacted sample.
  • Rough interior surface of liner (due to wear or damage).
  • Sèvi ak s ki apwopriyeample extrusion tools.
  • Consider replacing the liner if interior surface is compromised.
Liner gets stuck in core sampler.
  • Liner or sampler barrel is dirty.
  • Liner is slightly deformed.
  • Excessive force during insertion.
  • Clean both components thoroughly.
  • Inspect liner for subtle deformities; replace if needed.
  • Always insert gently.

Espesifikasyon

AtribiDetay
Nimewo Modèl405.57
Dyamèt Eksteryè1 1/2 pous (apeprè 3.81 cm)
Longè12 pous (apeprè 30.48 cm)
Epesè miray laApproximately 0.060 inches (approx. 1.52 mm)
MateryèlAliminyòm
Pwa apwoksimatif1 liv (apeprè 0.45 kg)
Dimansyon pake14 x 4 x 4 pous
ManifaktiAMS Incorporated
Peyi orijinEtazini
Dat Premye Disponib12 desanm 2017

Garanti ak sipò

Specific warranty information for the AMS 405.57 Aluminum Liner is not provided in this document. For details regarding product warranty, technical support, or replacement parts, please contact AMS Incorporated directly through their official websit oswa chanèl sèvis kliyan.

Manifakti: AMS Incorporated

Please refer to the manufacturer's official resources for the most current support information.

Dokiman ki gen rapò - 405.57

Preview Manyèl Twous Evalyasyon Kat Adaptè ams AS5600L la
Manyèl sa a bay enfòmasyon konplè pou kat adaptè ams AS5600L-WL_EK_AB la, ki gen ladan sa ki nan twous la, deskripsyon kat la, enstriksyon montaj, detay sou brochaj, operasyon mòd I2C, chema pyès ki nan konpitè, layout PCB, ak enfòmasyon sou kòmand.
Preview Manyèl Itilizatè Capteur Pozisyon Rotary ams AS5048 14-bit
Manyèl itilizatè sa a bay enfòmasyon detaye sou ams AS5048 la, yon detèktè pozisyon wotasyon 14-bit ak ang dijital ak pwodiksyon PWM. Li kouvri tablo adaptè AS5048 la, montaj, brochaj, ka operasyon (SPI, Daisy Chain), kodaj firmwèr, eks.amples, and hardware schematics. Essential for engineers integrating this sensor into their systems.
Preview Manyèl Twous Evalyasyon Kat Adaptè ams AS5048 la
Manyèl sa a detaye Kat Adaptè ams AS5048 la (AS5048-EK-AB), yon twous evalyasyon pou Capteur pozisyon mayetik AS5048 la. Li kouvri pyès ki nan konpitè a, mòd operasyon yo (SPI, I2C), lojisyèl...amples, and contact information for ams AG.
Preview Manyèl Twous Evalyasyon Kat Adaptè ams AS5048 la
Manyèl itilizatè pou Twous Evalyasyon Kat Adaptè ams AS5048 la (AS5048-EK-AB), ki detaye karakteristik li yo, delimitasyon broch, montaj, ka operasyon (mòd SPI), chema pyès ki nan konpitè, layout PCB, ak enfòmasyon kontak.
Preview AMS Wall Clock Operating Instructions
Operating instructions for AMS wall clocks, covering battery installation, replacement, and general usage in multiple languages.
Preview TSL2521 EVM User Guide: Ambient Light Sensor Evaluation Kit
User guide for the ams TSL2521 EVM, detailing its features as a highly sensitive ambient light sensor with selective flicker detection and fast sampling for use behind OLED or auxiliary to camera. Includes hardware and software descriptions, setup, and legal information.