Elitech RC-51H

Elitech RC-51H USB Temperature Data Logger Instruction Manual

Model: RC-51H

1. Entwodiksyon

The Elitech RC-51H is a reusable USB temperature data logger designed for precise and reliable temperature monitoring. This device is suitable for various applications including life sciences, food cold chain management, and industrial processes. It features a pen-style design, IP67 waterproof rating, and the ability to generate PDF reports without specialized software. This manual provides detailed instructions for setting up, operating, maintaining, and troubleshooting your RC-51H data logger.

2. Pwodwi souview

The RC-51H data logger is a compact and portable device. Key components include:

Elitech RC-51H data logger with labeled components

Image: Elitech RC-51H data logger with its transparent cap, USB port, LCD screen, seal ring, button with bi-color indicator, and temperature sensor clearly labeled.

  1. Transparent Cap: Pwoteje konektè USB a.
  2. Pò USB: Used for connecting to a computer for configuration and data download.
  3. Ekran LCD: Displays current temperature, humidity, maximum/minimum values, and logging status.
  4. Seal Ring: Ensures IP67 waterproof and dustproof protection when the cap is securely fastened.
  5. Button & Bi-color Indicator (Red and Green): Used for device operation (e.g., starting/stopping logging, cycling through display modes) and status indication.
  6. Capteur Tanperati: Integrated sensor for accurate temperature measurement.

The device also features a large data storage capacity of 32,000 points, allowing for continuous recording over extended periods.

Elitech RC-51H data logger showing 32000 points storage capacity

Image: The Elitech RC-51H data logger highlighting its 32,000 data point storage capacity.

3. Enstalasyon

3.1 Software Installation (Optional for PDF Report Generation)

While the RC-51H can generate PDF reports directly, the Elitechlog software offers advanced parameter settings and data analysis features. Download the latest version of Elitechlog software from the official Elitech websit.

3.2 Inisyal Konfigirasyon

  1. Remove the transparent cap to expose the USB connector.
  2. Plug the data logger into a USB port on your computer.
  3. If using Elitechlog software:
    • Open the Elitechlog software.
    • Navigate to the "Parameter" tab.
    • Adjust settings such as logging interval, temperature unit (Celsius/Fahrenheit), alarm thresholds, and start mode.
    • Click "Save Parameter" to apply the settings to the logger.
  4. Safely remove the data logger from the computer and replace the transparent cap, ensuring the seal ring is properly seated for IP67 protection.

Video: Elitech RC-51/RC-51H Data Logger Operation Guide. This video demonstrates how to connect the logger to a computer, configure parameters using the Elitechlog software, and prepare it for logging.

4. Operasyon

4.1 Starting Logging

To start logging, press the button once to activate the LCD screen. Then, press and hold the button for more than 4 seconds until a triangle symbol firmly lights up on the screen, indicating that logging has begun.

4.2 ViewDone sou LCD

During logging, a single press of the button will cycle through various display modes on the LCD screen, showing current temperature, humidity (if applicable), maximum/minimum values, and other relevant information.

Elitech RC-51H LCD screen indications

Imaj: Egzamples of LCD screen indications on the Elitech RC-51H, showing current temperature, humidity, average, maximum, and minimum values.

4.3 Stopping Logging

To stop logging, press and hold the button for more than 4 seconds until the logging indicator disappears or the screen displays "END".

5. Data Retrieval and Analysis

The RC-51H allows for quick data export without requiring software installation on the retrieval computer.

  1. Remove the transparent cap and plug the data logger into a USB port on your computer.
  2. The device will automatically generate an encrypted PDF report containing a summary, graph, and detailed data table.
  3. The logger will appear as a removable drive. Copy the generated PDF file nan òdinatè w lan.
  4. For advanced analysis, use the Elitechlog software to view data, generate Excel or TXT reports, and compare data from multiple loggers.
Elitech RC-51H connected to a laptop, showing automatic PDF report generation

Image: The Elitech RC-51H data logger connected to a laptop, illustrating the automatic generation of PDF reports without requiring additional software.

6. Antretyen

6.1 Netwayaj

Siye aparèy la avèk yon twal mou epi sèk. Evite itilize pwodui netwayaj abrazif oswa solvan ki ka domaje li.asing oswa ekran.

6.2 Ranplasman batri

The RC-51H uses 1 Lithium Metal battery. If the battery indicator on the LCD shows low power, replace the battery according to the instructions provided in the full user manual or consult Elitech support.

6.3 Pwoteksyon IP67

Ensure the transparent cap is securely fastened with the seal ring properly in place to maintain the IP67 waterproof and dustproof rating. This protects the USB port and internal components from environmental elements.

Video: Elitech RC-51 Pen-Style Design with Waterproof IP67. This video demonstrates the pen-style design and the IP67 waterproof feature of the data logger.

NAN. Depanaj

PwoblèmKòz posibSolisyon
Aparèy la pa vire.Batri ki fèb oswa ki vid.Ranplase batri a.
Logging does not start.Button not held long enough; incorrect start mode setting.Press and hold the button for 4 seconds until the logging indicator appears. Verify start mode in Elitechlog software.
Odinatè a pa rekonèt aparèy la.Improper USB connection; USB port issue; driver issue.Ensure secure connection. Try a different USB port. Reinstall Elitechlog software to ensure drivers are installed.
Rapò PDF la pa pwodui.Device memory full; corrupted data.Download data and clear device memory. If issue persists, contact support.

8. Espesifikasyon

KarakteristikDetay
Non modèlRC-51H
Ranje Tanperati-30 ° C a 70 ° C (-40 ° F a 185 ° F)
Presizyon Tanperati± 0.5 ° C (± 0.9 ° F)
Range imidite10% a 95% RH
Presizyon imidite± 3% RH
Done Kapasite32,000 pwen
Entèval LoggingConfigurable (e.g., 10 seconds to several hours)
KoneksyonUSB
Klas pwoteksyonIP67 (Enpèmeyab ak Rezistan a pousyè)
Sous pouvwa1 batri ityòm metal
DimansyonApproximately 3.14 inches (length)
KonfòmiteFDA 21 CFR Part 11 standard
Elitech RC-51H data logger with dimensions and specifications

Image: Elitech RC-51H data logger showing its physical dimensions and key specifications.

9. Garanti ak sipò

The Elitech RC-51H comes with a calibration certificate, indicating its adherence to quality standards. For warranty information, technical support, or service inquiries, please refer to the contact details provided in the packaging or visit the official Elitech websit.

Elitech RC-51H with a two-year validation certificate

Image: Elitech RC-51H data logger shown alongside a two-year validation certificate, confirming its calibration and quality.

Dokiman ki gen rapò - RC-51H

Preview Elitech RC-51H Temperature and Humidity Data Logger User Manual
User manual for the Elitech RC-51H Temperature and Humidity Data Logger. Provides information on product overview, structure, parameters, operation, technical specifications, and report interpretation.
Preview Elitech RC-51H User Manual: Temperature and Humidity Data Logger
Comprehensive user manual for the Elitech RC-51H, a multi-use temperature and humidity data logger. Learn about its features, specifications, operating instructions, and data reporting.
Preview Elitech RC-51H User Manual: Temperature & Humidity Data Logger
Comprehensive user manual for the Elitech RC-51H multi-use temperature and humidity data logger. Covers product overview, structure, parameters, operating instructions, technical specifications, report generation, and battery replacement.
Preview Manyèl Itilizatè Anrejistrè Done Tanperati ak Imidite Milti-Itilizasyon Elitech RC-51H
Manyèl itilizatè pou anrejistre done tanperati ak imidite milti-itilizasyon Elitech RC-51H la. Kouvri pwodwi a plis paseview, estrikti, paramèt anviwònman, enstriksyon operasyon, espesifikasyon teknik, estati endikatè, fonksyon meni, ranplasman batri, ak detay rapò.
Preview Elitech RC-51H Temperature and Humidity Data Logger User Manual
Comprehensive user manual for the Elitech RC-51H multi-use temperature and humidity data logger. Covers product overview, structure, parameters, operation, technical specifications, and report generation.
Preview Manyèl Itilizatè Elitech RC-51H: Gid pou Anrejistrè Done Tanperati ak Imidite
Manyèl itilizatè konplè pou anrejistrè done tanperati ak imidite milti-itilizasyon Elitech RC-51H la. Aprann sou karakteristik li yo, operasyon li, espesifikasyon teknik li yo, ak kijan pou itilize li pou siveyans ak anrejistreman done anviwònman yo.