This manual provides detailed instructions for the installation, operation, and maintenance of your Ecolink Z-Wave Plus Flood and Freeze Sensor. The sensor is designed to detect water leaks and dangerously low temperatures, providing timely alerts to help prevent potential damage to your property. Its compact design allows for flexible placement in high-risk areas such as under sinks, near toilets, behind refrigerators, or in basements.

2. Enfòmasyon sou Sekirite

  • Li tout enstriksyon yo ak anpil atansyon anvan enstalasyon ak itilize.
  • Do not expose the sensor to extreme temperatures or humidity outside its operating range.
  • Use only the specified battery type (CR123A lithium). Incorrect battery usage may cause damage or fire.
  • Kenbe aparèy la ak konpozan li yo lwen timoun yo.
  • Jete pil yo selon règleman lokal yo.

3. Pake kontni

Verifye ke tout atik yo prezan nan pakè ou a:

  • Ecolink Z-Wave Plus Flood and Freeze Sensor (Main Unit)
  • Water Probe with 36-inch cable
  • 1x CR123A Lithium Battery
  • Mounting Hardware (screws/adhesive)

4. Pwodwi souview

Ecolink Z-Wave Plus Flood and Freeze Sensor connected
Figi 4.1: The Ecolink Z-Wave Plus Flood and Freeze Sensor, showing the main unit connected to the water probe via a cable.
Ecolink Z-Wave Plus Flood and Freeze Sensor components
Figi 4.2: The main sensor unit and the separate water probe, highlighting the two metal contacts on the probe for water detection.
CR123A Lithium Battery for Ecolink Sensor
Figi 4.3: Illustration indicating the use of a single CR123A lithium battery for the sensor.
Smartphone displaying flood alarm notification
Figi 4.4: A smartphone screen showing a 'Flood Alarm' notification, demonstrating the sensor's alert capability.

5. Enstalasyon

5.1. Enstalasyon batri

  1. Open the battery compartment on the main sensor unit.
  2. Insert the provided CR123A lithium battery, ensuring correct polarity.
  3. Close the battery compartment securely. The sensor is designed for a long battery life, typically up to five years.

5.2. Z-Wave Inclusion (Pairing)

To integrate the sensor with your Z-Wave network:

  1. Put your Z-Wave controller/hub into inclusion (pairing) mode. Refer to your controller's manual for specific instructions.
  2. With the battery installed, the sensor will automatically attempt to pair. If it doesn't, you may need to briefly remove and reinsert the battery.
  3. Confirm that your Z-Wave controller recognizes the sensor. The sensor's LED indicator may flash to confirm successful inclusion.

5.3. Z-Wave Exclusion (Unpairing)

To remove the sensor from your Z-Wave network:

  1. Put your Z-Wave controller/hub into exclusion (unpairing) mode.
  2. Briefly remove and reinsert the battery into the sensor.
  3. Confirm that your Z-Wave controller indicates successful exclusion.

5.4. Capteur plasman

Strategic placement is key for effective monitoring:

  • Place the water probe directly on the floor in areas prone to leaks, such as under sinks, behind toilets, near water heaters, washing machines, or dishwashers.
  • The 36-inch probe cable allows the main unit to be mounted in a more accessible location (e.g., on a wall or cabinet side) while the probe remains at floor level.
  • Ensure the two metal contacts on the water probe are facing downwards and can make direct contact with any pooling water.
  • For freeze detection, place the main unit in an area where temperature monitoring is critical, such as an attic, basement, or utility room.

6. Operasyon Enstriksyon

6.1. Flood Detection

When water bridges the two metal contacts on the water probe, the sensor will detect a flood condition. It will then send an alert to your Z-Wave controller, which can trigger notifications (e.g., text messages, app alerts) or automated actions (e.g., shutting off a water valve, turning on lights).

6.2. Freeze Detection

The sensor continuously monitors the ambient temperature. If the temperature drops to 41℉ (5℃) or below, the sensor will send a freeze alert to your Z-Wave controller. This can be used to notify you of potential pipe freezing conditions or to activate smart thermostats to increase heating.

6.3. Endikatè ki ap dirije

The LED indicator on the main unit provides visual feedback during operation and pairing. A brief flash typically indicates successful communication or a change in status (e.g., flood detected).

7. Antretyen

7.1. Ranplasman batri

When the battery level is low, the sensor will report this status to your Z-Wave controller. Replace the CR123A lithium battery as described in Section 5.1. Ensure proper disposal of the old battery.

7.2. Netwayaj

Periodically inspect the water probe for any debris or corrosion on the metal contacts. Clean with a soft, dry cloth if necessary. Do not use abrasive cleaners or immerse the main unit in water.

NAN. Depanaj

  • Capteur a pa konekte: Ensure your Z-Wave controller is in inclusion mode. Try removing and reinserting the battery. Ensure the sensor is within range of your Z-Wave network.
  • No alerts: Verify the sensor is successfully paired with your Z-Wave controller. Check the battery level. Ensure your Z-Wave controller's automation rules for flood/freeze alerts are correctly configured.
  • Fo alam: Ensure the water probe contacts are clean and dry. Reposition the probe if it is inadvertently coming into contact with moisture.
  • Kout lavi batri: While designed for long battery life, frequent Z-Wave communication (e.g., due to poor network signal requiring retries) can reduce battery life. Ensure a strong Z-Wave mesh network.

9. Espesifikasyon

KarakteristikSpesifikasyon
Nimewo ModèlFLF-ZWAVE5-ECO
Sous pouvwa1x CR123A Lithium Battery (3 Volts)
Lavi batriUp to 5 years (typical)
Flood DetectionWater Probe with 36-inch cable
Freeze Detection Threshold41℉ (5℃)
Pwotokòl san filZ Vag Plus
Dimansyon pwodwi4.13"L x 1.65"W x 3.22"H (Main Unit)
Pwa atik2.24 ons
Kalite aliyeWall Mount (for main unit)
UPC851166005091

10. Enfòmasyon sou Garanti

The Ecolink Z-Wave Plus Flood and Freeze Sensor comes with a 2-year limited warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage caused by misuse, accident, unauthorized modification, or improper installation. For warranty claims, please retain your proof of purchase and contact customer support.

11. Sipò

For technical assistance, troubleshooting, or further information regarding your Ecolink Z-Wave Plus Flood and Freeze Sensor, please visit the official Ecolink website or contact their customer support department. Contact details can typically be found on the product packaging or the manufacturer's websit.

Dokiman ki gen rapò - FLF-ZWAVE5-ECO

Preview Gid Enstalasyon ak Konpatibilite Switch Entelijan Ecolink Z-Wave Plus la
Gid konplè pou enstale ak konfigirasyon switch entelijan Ecolink Z-Wave Plus yo, ki gen ladan detay sou modèl ak bouton baskile ak bouton baskile, etap enstalasyon yo, ak konpatibilite ak sant kay entelijan popilè tankou Samsung SmartThings ak Vera.
Preview Ecolink Z-Wave Plus Smart Switch Single Rocker Installation Guide
Installation guide for the Ecolink Z-Wave Plus Smart Switch Single Rocker (SDLS2-ZWAVE5). Covers product overview, features, specifications, installation steps, network inclusion/exclusion, LED status, battery information, Z-Wave Plus details, command classes, FCC compliance, warranty, and return policy.
Preview Gid Enstalasyon Entèrijan Ecolink Z-Wave Plus Doub Rocker
Gid enstalasyon konplè pou Ecolink Z-Wave Plus Smart Switch Dual Rocker (DDLS2-ZWAVE5). Kouvri pwodwi a plis pase...view, karakteristik, espesifikasyon, etap enstalasyon, enklizyon/esklizyon rezo, estati LED, ak enfòmasyon sou konfòmite teknik.
Preview Ecolink GDZW7-ECO Z-Wave Long Range Garage Door Controller Installation and User Manual
Comprehensive installation instructions and user manual for the Ecolink GDZW7-ECO Z-Wave Long Range Garage Door Controller. Learn how to add the device to your Z-Wave network, mount the controller and tilt sensor, connect to your garage door opener, and troubleshoot common issues.
Preview Ecolink GDZW7-ECO Z-Wave Long Range Garage Door Controller Installation Manual
Comprehensive installation instructions and user manual for the Ecolink GDZW7-ECO Z-Wave Long Range Garage Door Controller. Learn how to add the device to your Z-Wave network, mount the tilt sensor and controller, connect to your garage door opener wirelessly or wired, and troubleshoot common issues. Includes specifications, package contents, and warranty information.
Preview Ecolink DWZW8-ECO Long Range Contact Sensor User Manual
User manual and installation guide for the Ecolink DWZW8-ECO Long Range Contact Sensor, detailing specifications, setup, operation, troubleshooting, and FCC compliance.