AMOCAM K80

AMOCAM K80 Power Supply Control User Manual

Modèl: K80

1. Entwodiksyon

This user manual provides detailed instructions for the installation, operation, and maintenance of the AMOCAM K80 Power Supply Control unit. This device is designed to provide stable DC 12V power for various door access control systems, including electric locks, access controllers, and exit buttons. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. Enfòmasyon sou Sekirite

3. Pwodwi Features

4. Espesifikasyon

ModèlK80 (Item Model Number: 12V-Powers)
Antre VoltageAC 110-240V, 50-60Hz
Sòti VoltageDC 12V, 3A
Lock Delay TimeReglabl 0-15 segonn
Dimansyon (L x W x H)5.5 x 3.7 x 1.5 pous (apeprè 140 x 94 x 38 mm)
Pwa atik11.1 ons (315 gram)
ManifaktiAMOCAM
UPC647726600253

5. Enstalasyon ak Enstalasyon

Before beginning installation, ensure all power is disconnected. The AMOCAM K80 Power Supply Control unit is designed for easy integration into existing or new access control systems.

5.1 Idantifikasyon konpozan

AMOCAM K80 Power Supply Control unit, front view
Figi 1: Devan view of the AMOCAM K80 Power Supply Control unit. This image displays the main unit with its input/output labels and terminal block.
Internal components of AMOCAM K80 Power Supply Control
Figi 2: Entèn view of the AMOCAM K80 Power Supply Control unit with the cover removed, showing the circuit board and components.

The unit features clearly labeled terminals for input power, control signals, and output to electric locks. A red LED indicates power status.

5.2 Dyagram fil elektrik

Refer to the following diagrams for correct wiring configurations.

5.2.1 AC Input Wiring

Wiring diagram for AC 110-240V input to K80 Power Supply Control
Figi 3: Diagram illustrating the connection of AC 110-240V input power to the AMOCAM K80 unit, typically through a circuit breaker.

Connect the AC 110-240V power source to the designated AC input terminals on the K80 unit. It is recommended to connect through a circuit breaker for safety.

5.2.2 Access Control System Wiring

Detailed wiring diagram for K80 Power Supply Control with access control keypad, exit button, and electric locks
Figi 4: Detailed wiring connections for an access control system, showing the K80 power supply connected to an access control keypad, an exit switch button, and both Normally Closed (NC) and Normally Open (NO) electric locks.
Wiring diagram for K80 Power Supply Control with video doorbell, access control keypad, exit button, and electric locks
Figi 5: Comprehensive wiring diagram demonstrating the integration of the K80 power supply with a video doorbell, access control keypad, exit button, and both NC and NO electric locks.

The K80 unit provides terminals for:

Ensure all connections are secure and correctly matched to the corresponding terminals on your access control devices and electric locks.

6. Operasyon

6.1 Limen

Once all wiring is complete and verified, connect the AC power. The red "POWER" indicator LED on the K80 unit should illuminate, indicating that the unit is receiving power and providing DC 12V output.

6.2 Adjusting Lock Delay Time

Close-up of the K80 Power Supply Control showing the adjustable unlock time dial
Figi 6: Image highlighting the adjustable time dial on the K80 unit, which controls the unlock delay from 0 to 15 seconds.

The K80 unit features an adjustable dial for setting the lock release delay time. This dial is typically located on the side or bottom of the unit and can be adjusted using a small screwdriver. The delay can be set from 0 to 15 seconds, allowing the connected electric lock to remain open for the desired duration after activation.

6.3 Lock Control

The K80 unit controls electric locks via its NC and NO outputs.

When an access control device (e.g., keypad, exit button) sends a signal to the K80 unit, it will momentarily cut or apply power to the connected lock terminals based on the lock type (NC/NO) and the set delay time, thereby releasing or securing the lock.

7. Antretyen

NAN. Depanaj

PwoblèmKòz posibSolisyon
No power indicator (red LED off)No AC input power; faulty wiring; internal fuse blown.
  • Tcheke sous kouran AC a ak koneksyon yo.
  • Verify wiring to AC input terminals.
  • If power is present and wiring is correct, contact support.
Electric lock does not open/closeIncorrect lock wiring (NC/NO); faulty lock; insufficient power; incorrect delay setting.
  • Verify lock type (NC/NO) and ensure it's connected to the correct terminals.
  • Check connections between K80 and the lock.
  • Ensure the access control device is sending a proper signal.
  • Adjust the lock delay time.
  • Test the lock independently if possible.
Lock opens/closes too quickly/slowlyIncorrect lock delay time setting.Adjust the "Time" dial on the K80 unit to the desired delay (0-15 seconds).
Inite a santi l choOverload; poor ventilation.
  • Ensure total current draw of connected devices does not exceed 3A.
  • Provide adequate ventilation around the unit.
  • If overheating persists, disconnect power and contact support.

9. Garanti ak sipò

For warranty information or technical support, please contact AMOCAM customer service. Refer to your purchase documentation for specific warranty terms.

AMOCAM Technology Inc. is committed to providing high-quality products and customer support.

Dokiman ki gen rapò - K80

Preview PNI K80 Alimantasyon ak Distribisyon - Manyèl Itilizatè ak Espesifikasyon Teknik
Dokiman sa a bay enfòmasyon detaye sou ekipman pouvwa PNI K80 la ak distribisyon tan, ki gen ladan karakteristik prensipal li yo, espesifikasyon teknik, ak dyagram fil elektrik. Li kouvri enstalasyon, operasyon, ak prekosyon sekirite pou itilizasyon ak kadna elektwomayetik ak mekanik.
Preview PNI K80 Power Supply with Timing User Manual
This document provides detailed information about the PNI K80 power supply with timing, including its features, technical specifications, wiring diagrams, and important warnings for installation and use.
Preview Manyèl Itilizatè ORSKEY Seri K - Enstalasyon, Operasyon, ak Depanaj
Manyèl itilizatè konplè pou kamera tablodbò ORSKEY Seri K a, ki kouvri demaraj rapid, fini pwodwi a.view, enstalasyon, gidans operasyon, paramèt sistèm, depanaj, ak konfòmite FCC.
Preview SilverCloud YS810/YS800 Electric Lock User Manual and Installation Guide
User manual and technical guide for SilverCloud YS810 and YS800 electric locks, detailing features, safety warnings, installation instructions, connection diagrams, and EU conformity.
Preview Manyèl Itilizatè Limyè Videyo Pwofesyonèl Pixel K80 RGB
Manyèl itilizatè pou Pixel K80 RGB Professional Video Light la, ki detaye espesifikasyon yo, konpozan yo, ikòn entèfas yo, enstalasyon an, ak mòd operasyon yo, ki gen ladan efè HSI, CCT, ak FLS yo. Aprann sou paramèt klète, tanperati koulè, ak efè limyè yo.
Preview Manyèl Itilizatè ORSKEY K80 ak Enfòmasyon sou Konfòmite
Dokiman sa a bay enfòmasyon sou vèsyon an epi li detaye divès sètifikasyon konfòmite pou pwodwi ORSKEY K80 la, tankou mak CE, UKCA, FCC, RoHS, ak PSE.