1. Pwodwi souview
The Hilti CP 606 Firestop Sealant is a high-performance, intumescent acrylic sealant designed for firestopping applications. It expands when exposed to heat, forming a fire-resistant barrier that helps prevent the spread of fire and smoke through penetrations in fire-rated constructions. This product is suitable for various joint and penetration sealing applications in walls and floors.

An image showing a single 10.5oz tube of Hilti CP 606 red firestop sealant, clearly displaying the Hilti logo and product identification.
2. Enfòmasyon sou Sekirite
Always prioritize safety when working with sealants. Read and understand the Safety Data Sheet (SDS) before use. Observe all local safety regulations.
- Ekipman Pwoteksyon Pèsonèl (PPE): Wear appropriate PPE, including safety glasses, gloves, and protective clothing, to prevent skin and eye contact.
- Vantilasyon: Use in well-ventilated areas. If adequate ventilation is not available, use respiratory protection.
- Kontak po: Nan ka kontak po, lave byen ak savon ak dlo.
- Kontak zye: In case of eye contact, flush immediately with plenty of water for several minutes and seek medical attention.
- Enjèstyon: Pa vale. Si vale, chèche swen medikal imedyatman.
- Kenbe soti nan rive: Kenbe lwen timoun ak bèt kay.
3. Enstalasyon ak Preparasyon
- Preparasyon sifas: Ensure all surfaces to be sealed are clean, dry, and free from dust, oil, grease, loose particles, and other contaminants. Substrates should be sound and stable.
- Joint Dimensions: Verify that joint dimensions are within the product's specified limits for optimal performance.
- Materyèl sipò: For deeper joints, use a suitable backing material (e.g., backer rod) to control sealant depth and ensure proper sealant geometry.
- Zouti obligatwa:
- Standard caulking gun
- Utility knife or sealant cutter
- Trowel or tooling stick for finishing
- Cleaning supplies (rags, appropriate solvent if needed)
- Tanperati: Apply the sealant within the recommended temperature range, typically between 5°C and 40°C (41°F and 104°F).
4. Enstriksyon pou aplikasyon an
- Prepare katouch la: Cut the tip of the sealant tube at a 45-degree angle to the desired bead size. Puncture the inner seal of the cartridge.
- Load Caulking Gun: Insert the prepared cartridge into a standard caulking gun.
- Aplike selan: Apply the sealant evenly and continuously into the joint or penetration, ensuring full contact with the substrate. Maintain consistent pressure on the trigger to achieve a smooth, uniform bead.
- Outils: Within 5-10 minutes of application (before skinning occurs), tool the sealant to ensure good adhesion and a smooth finish. Remove any excess sealant immediately.
- Geri: The sealant will skin over in approximately 15-30 minutes, depending on temperature and humidity. Full cure time can range from several days to weeks, depending on bead thickness and environmental conditions. Protect the freshly applied sealant from water and heavy traffic until fully cured.
5. Antretyen
Once cured, Hilti CP 606 Firestop Sealant requires minimal maintenance. Periodically inspect sealed joints and penetrations for any signs of damage, cracking, or degradation. If damage is observed, clean the area and reapply sealant as necessary to maintain the firestop integrity.
NAN. Depanaj
- Pòv adezyon:
Ensure surfaces are clean, dry, and free of contaminants. Proper surface preparation is critical for good adhesion.
- Slow Curing:
Low temperatures and high humidity can extend curing times. Ensure adequate ventilation and maintain recommended application temperatures.
- Cracking or Shrinkage:
Excessive joint movement or improper joint design can lead to cracking. Ensure correct joint dimensions and use of backing material where appropriate.
7. Espesifikasyon
| Karakteristik | Detay |
|---|---|
| Mak | HILTI |
| Nimewo Modèl | 3436798 (CP 606) |
| Fòm Atik | Liquid (Sealant) |
| Koulè | Wouj |
| Gwosè veso | 10.5 oz Tube |
| Nivo rezistans dlo | Ki enpèmeyab |
| Manifakti | Hilti |
| Premye Dat ki disponib | 9 oktòb 2017 |
8. Depo ak jete
- Depo: Store the sealant in its original, unopened packaging in a cool, dry place, away from direct sunlight and extreme temperatures. Recommended storage temperature is typically between 5°C and 25°C (41°F and 77°F).
- Dispozisyon: Dispose of unused product and empty containers in accordance with local, state, and federal regulations. Do not dispose of in drains or waterways. Consult local waste management authorities for proper disposal methods.
9. Garanti ak sipò
For specific warranty information regarding the Hilti CP 606 Firestop Sealant, please refer to the official Hilti website or contact Hilti customer service directly. Hilti provides comprehensive technical support and product documentation to assist with proper application and performance.
Hilti Ofisyèl Websit: www.hilti.com