This manual provides detailed instructions for the installation, operation, and maintenance of your AIMS Power 2000 Watt 12V Pure Sine Inverter Charger. This unit combines an inverter, battery charger, and AC auto-transfer switch into a single system, designed for various applications including renewable energy systems, utility backup, RVs, and emergency vehicles. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.

2. Enfòmasyon sou Sekirite

WARNING: Improper installation or operation can result in serious injury or death. Always follow safety guidelines.

  • Ensure proper DC input voltage. Incorrect voltage may permanently damage the inverter and void the warranty.
  • Do not block ventilation openings. The system is air-cooled, and a clearance of approximately 1 foot (30cm) is recommended around the unit for proper airflow.
  • Always connect the battery with correct polarity. Reverse polarity will cause damage.
  • Ensure all connections are secure to prevent loose connections, which can cause overheating and fire.
  • Inite sa a gen gwo volimtage. Do not attempt to open or service the unit unless you are a qualified technician.
  • Ground the unit properly according to local electrical codes.

3. Pwodwi Features

  • Sòti pwisan: 2000W continuous pure sine wave power, with a 6000W surge capacity for 20 seconds.
  • Integrated Charger: 70A smart battery charger with multi-stage charging for 8 different battery technologies, including lithium.
  • Auto Transfer Switch: Seamless power transfer with approximately 10ms typical transfer time when utility or generator power is present.
  • Pwoteksyon konplè: Includes overload, over-temperature, high voltage, ba voltage, short circuit, and internally fused protection. Features low and high voltage alam.
  • Adjustable Charge Current: Charging current is adjustable from 0-100% for precise control over battery banks.
  • Mode ekonomize pouvwa: Designed to conserve battery power by entering a search mode when AC loads are low or infrequent.
  • ETL sètifye: Listed to UL 458 for land vehicles and marine crafts.
  • Karakteristik pratik: GFCI outlet, AC direct connect terminal block, charge current control dial, dip switches for priority settings, auto generator start functionality, and conformal coated components.

4. Konpozan souview

Familiarize yourself with the various components and connection points of the inverter charger.

Dèyè view of AIMS Power Inverter Charger with labeled components

Figure 4.1: Rear Panel Connections and Controls
This image displays the rear panel of the AIMS Power Inverter Charger, highlighting key components such as the DC terminals (positive and negative), charge current control dial, on/off power switch, LCD remote port, dip switches, auto generator start terminal, optional battery temperature sensor port, and grounding DC terminal.

Dèyè view of AIMS Power Inverter Charger showing DC connections

Figure 4.2: Detailed DC Terminal View
A closer look at the rear panel, emphasizing the large positive and negative battery terminal connectors for 12 VDC or 24 VDC systems. Important warnings regarding battery polarity and proper cable lug installation are visible.

Devan view of AIMS Power Inverter Charger showing AC output and input

Figure 4.3: AC Input and Output Connections
This image shows the side panel with the AC input and output connections, including the GFCI output receptacle and the hardwire terminal block for AC output. The ETL Listed mark is also visible.

4.1 Front Panel (Not explicitly shown in detail, but general controls)

  • Pouvwa switch: Kontwole kouran prensipal ki bay envèstisè a.
  • Endikatè ki ap dirije: Display operational status, fault conditions, and charging status.

4.2 Rear Panel (Refer to Figure 4.1 and 4.2)

  • DC Terminals: Large terminals for connecting to the 12V battery bank. Ensure correct polarity (Positive + and Negative -).
  • Tèminal baz: For connecting the unit to an earth ground.
  • LCD Remote Port: For connecting an optional LCD remote display.
  • Dip switch: Used to configure various settings such as battery type, charge voltage, and power saver mode.
  • Charge Current Control Dial: Adjusts the battery charging current.
  • Auto Generator Start Terminal: For connecting to a compatible generator for automatic starting.
  • Battery Temp Sensor Port: For connecting an optional battery temperature sensor to optimize charging.

4.3 Side Panel (Refer to Figure 4.3)

  • Antre AC: Connection point for utility or generator AC power.
  • AC Sòti: Connection point for AC loads.
  • GFCI Output: A standard AC outlet with Ground Fault Circuit Interrupter protection.
  • Disjoncteurs: Protect AC output circuits.

5. Enstalasyon ak Enstalasyon

Proper installation is crucial for the safe and efficient operation of your inverter charger. If you are unsure about any step, consult a qualified electrician or technician.

5.1 Monte inite a

  • Mount the inverter charger in a dry, well-ventilated area, away from direct sunlight, heat sources, and flammable materials.
  • Ensure at least 1 foot (30cm) of clearance around the unit for proper airflow and cooling.
  • Mount the unit securely to a stable surface using appropriate fasteners.

5.2 DC Battery Connections

  • Kalite batri: This unit is designed for 12V battery banks. Ensure your battery bank voltage koresponn ak volim antre envèstisè atage.
  • Gwosè Kab: Use appropriately sized cables for your battery connections to minimize voltage drop and ensure safety. Refer to electrical codes or a qualified professional for correct sizing.
  • Lòd Koneksyon:
    1. Konekte kab negatif (-) batri a ak tèminal negatif (-) sou envèstisè a.
    2. Konekte kab pozitif (+) batri a ak tèminal pozitif (+) ki sou envèstisè a.
    3. Connect the other end of the negative (-) cable to the negative (-) terminal of your battery bank.
    4. Connect the other end of the positive (+) cable to the positive (+) terminal of your battery bank.
  • Koneksyon an sekirite: Ensure all connections are tight and secure. Loose connections can cause arcing and overheating.

5.3 AC Wiring Connections

  • Antre AC: Connect the utility grid or generator AC power to the AC input terminals. Ensure the input voltage and frequency are compatible with the inverter charger.
  • AC Sòti: Connect your AC loads to the AC output terminals or use the GFCI outlet.
  • Atè: Connect the grounding terminal of the inverter charger to a reliable earth ground.
  • Awondisman Pwoteksyon: Ensure appropriate circuit breakers are installed on both AC input and output lines as per local electrical codes.

5.4 Remote Control and Sensor Connections (Optional)

  • LCD Remote: If using an optional LCD remote, connect it to the designated LCD remote port on the rear panel.
  • Capteur Tanperati Batri: If using an optional battery temperature sensor, connect it to the battery temp sensor port and attach the sensor to the battery bank for accurate temperature compensation during charging.
  • Auto Generator Start: Connect compatible auto generator start wiring to the designated terminal if this feature is desired.

6. Operasyon Enstriksyon

6.1 Premye pouvwa-up

  • After all connections are securely made and verified, switch on the DC power from the battery bank (if a disconnect switch is used).
  • Turn the main power switch on the inverter charger to the "ON" position.
  • Observe the LED indicators for normal operation. Refer to the troubleshooting section if any fault indicators illuminate.

6.2 Configuring Settings (Dip Switches)

The dip switches on the rear panel allow configuration of various operational parameters. Refer to the label on the unit or the full user manual for specific dip switch settings for battery type, charge voltage, and power saver mode. Ensure the unit is powered off before changing dip switch settings.

6.3 Operasyon varyateur

  • When the unit is powered on and no AC input is present, the inverter will convert DC battery power to AC power for your connected loads.
  • Mode ekonomize pouvwa: This mode reduces idle power consumption. When activated via dip switch, the inverter will periodically "search" for a load. If a load greater than 50W is detected, the inverter will fully activate. If no load is detected, it returns to low-power search mode.

6.4 Charger Operation

  • When external AC power (utility or generator) is connected to the AC input, the unit will automatically begin charging the battery bank.
  • Charge Current Control: Use the charge current control dial to adjust the charging amperage. This is useful for smaller battery banks or when using a generator with limited output.
  • Multi-Stage Chaje: The charger employs a multi-stage charging process (bulk, absorption, float) to optimize battery health and lifespan.

6.5 AC Auto-Transfer Switch

  • When external AC power is detected at the input, the unit will automatically transfer the AC loads from inverter power to the external AC source. This transfer typically occurs within 10 milliseconds.
  • When external AC power is lost, the unit will automatically switch back to inverter power, drawing from the battery bank.

7. Antretyen

  • Enspeksyon regilye: Periodically inspect all wiring connections for tightness and corrosion. Clean any corrosion with a wire brush and baking soda solution.
  • Vantilasyon: Ensure ventilation openings are clear of dust and debris. Clean with compressed air if necessary.
  • Antretyen batri: Follow the manufacturer's recommendations for your specific battery type. This may include checking electrolyte levels for flooded lead-acid batteries.
  • Kondisyon anviwònman: Keep the unit in a dry, cool environment. Avoid exposure to moisture, extreme temperatures, and corrosive fumes.

NAN. Depanaj

This section addresses common issues you might encounter. For more complex problems, contact AIMS Power technical support.

8.1 No AC Output from Inverter

  • Check DC Connections: Ensure battery cables are securely connected and not corroded.
  • Batri Voltage: Verify batri voltage is within the operating range (e.g., above low voltage cut-off). Charge batteries if low.
  • Surcharge: Disconnect some AC loads. The inverter may have shut down due to an overload.
  • Sur-tanperati: Ensure adequate ventilation. Allow the unit to cool down if it has overheated.
  • Entèn Fusible: If the unit is completely unresponsive, an internal fuse may have blown. This requires professional service.

8.2 Pil yo pa chaje

  • Antre AC: Verify that external AC power is present and connected to the inverter's AC input.
  • AC Input Breaker: Check if the AC input circuit breaker on the unit or external panel has tripped.
  • Charge Current Dial: Ensure the charge current control dial is not set to zero.
  • Battery Type Settings: Confirm dip switch settings match your battery type.

8.3 GFCI Outlet Trips Frequently

  • Fay Tè: A ground fault may exist in the connected appliance or wiring. Disconnect appliances one by one to identify the faulty one.
  • Surcharge: The connected load might be exceeding the GFCI outlet's rating.

9. Espesifikasyon

KarakteristikSpesifikasyon
ModèlPICOGLF20W12V120V
Wat kontinyèltage2000 Watts
Vag Wattage6000 Watt (20 segonn)
DC Antre Voltage12 Volts
AC Sòti Voltage120 Volts
Sòti OndVag sinis pi
Kouran chajè batri70 Amps (reglabl)
Tan transfèApeprè 10ms
Dimansyon21 x 13.8 x 12.4 pous
Pwa atik55 liv
SètifikasyonETL Certified to UL 458

10. Garanti ak sipò

AIMS Power offers a 2-ane garanti on this product. For technical assistance, warranty claims, or further information, please contact AIMS Power directly. All technical and warranty support is provided from their facility in Nevada, USA.

Pou plis resous, ou ka vizite Magazen AIMS Power sou Amazon.

Dokiman ki gen rapò - PICOGLF20W12V120V

Preview Manyèl Itilizatè Chargeur Onduleur Vag Sinis Pi AIMS Power Global Seri LF la
Manyèl itilizatè pou chajè envèstisè sinisoid AIMS Power Global LF Series la, ki detaye enstalasyon, operasyon, karakteristik ak depanaj pou modèl PICOGLF10W12V120V, PICOGLF15W12V120V, PICOGLF20W12V120V, ak PICOGLF30W12V120V.
Preview AIMS Power Global LF Series Pure Sine Wave Inverter/Charger User Manual
User manual for the AIMS Power Global LF Series Pure Sine Wave Inverter/Charger. Covers installation, operation, safety, key features like pure sine wave output, battery charging, automatic transfer, and applications in renewable energy, RVs, and vehicles.
Preview Manyèl Enstriksyon AIMS Power PWRI200012120S DC pou AC Puisans Sinis Pi
Instruction manual for the AIMS Power PWRI200012120S 2000W Pure Sine Power Inverter, covering safety, features, installation, operation, troubleshooting, specifications, and warranty.
Preview Manyèl Enstriksyon pou Envèstisè Vag Sinis Pi AIMS Power PWRI200012120S 2000W
Manyèl enstriksyon pou onduleur kouran AIMS Power PWRI200012120S 2000W Pure Sine Wave DC pou AC. Li kouvri entwodiksyon, avètisman sekirite, karakteristik, enstalasyon, kondisyon batri, koneksyon, operasyon, pwoteksyon, depanaj, espesifikasyon, ak garanti.
Preview Manyèl Operasyon AIMS Power Pure Sine Wave Inverter - Espesifikasyon ak Gid
Manyèl operasyon konplè pou envèstisè sinis pi AIMS Power yo, ki kouvri espesifikasyon, karakteristik, dyagram koneksyon, pwosedi operasyon, depanaj, ak avètisman sekirite pou modèl seri PWRIG1000, PWRIG1500, PWRIG2000, ak PWRIG3000.
Preview Manyèl Enstriksyon AIMS Power PWRI200012120S DC pou AC Puisans Sinis Pi
This instruction manual provides comprehensive details for the AIMS Power PWRI200012120S DC to AC Pure Sine Power Inverter. It covers product introduction, essential safety warnings, key features, installation guidelines, battery requirements, connection procedures, operational instructions, built-in protections, troubleshooting tips, technical specifications, and warranty information.