OWON SDS6062

OWON SDS6062 60MHz Digital Storage Oscilloscope User Manual

Model: SDS6062 | Brand: OWON

1. Entwodiksyon

This manual provides essential information for the safe and effective operation of your OWON SDS6062 Digital Storage Oscilloscope. Please read this manual thoroughly before using the device to ensure proper setup, operation, and maintenance. The SDS6062 is a 2-channel oscilloscope featuring a 60 MHz bandwidth, 500 MS/s sample rate, and a 10M record length, designed for precise electrical signal analysis.

2. Enfòmasyon sou Sekirite

Always observe the following safety precautions to prevent injury and avoid damage to the instrument or any connected products. Read these instructions carefully before operation.

  • Sous pouvwa: Use only the power adapter supplied with the instrument. Ensure the voltage matche ak ekipman pou kouran lokal ou a.
  • Atè: The oscilloscope must be properly grounded to prevent electric shock.
  • Sonde sekirite: Do not connect the probe ground lead to a point where a voltage greater than 30V RMS or 42.4V peak is present.
  • Anviwònman: Operate the device in a well-ventilated area, away from moisture, dust, and direct sunlight. Avoid operating in explosive atmospheres.
  • Antretyen: Konfye tout sèvis bay pèsonèl sèvis kalifye. Pa eseye repare aparèy la tèt ou.

3. Pake kontni

Verify that all items listed below are present in your package. If any items are missing or damaged, contact your supplier.

  • OWON SDS6062 Digital Storage Oscilloscope Unit
  • 2 x Oscilloscope Probes
  • 1 x pouvwa kòd
  • 1 x Probe Adjust Pen
  • 1 x USB Done kab
  • 1 x lojisyèl CD
  • 1 x Manyèl Itilizatè (dokiman sa a)

4. Pwodwi souview

The OWON SDS6062 is a compact and powerful digital storage oscilloscope. It features an 8-inch (800x600) color TFT-LCD screen for clear waveform display and an intuitive control panel for easy operation. Key features include its 60 MHz bandwidth, 500 MS/s real-time sample rate, and 10M record length, making it suitable for a wide range of applications.

OWON SDS6062 Digital Storage Oscilloscope front view avèk ekran ak kontwòl

Figi 4.1: Devan view of the OWON SDS6062 Digital Storage Oscilloscope, showing the display, control knobs, and function buttons.

4.1 Kontwòl Panel Front

The front panel includes the main display, vertical controls (VOLTS/DIV, position), horizontal controls (SEC/DIV, position), trigger controls, and various function buttons for menu navigation, measurement, and utility settings.

4.2 Koneksyon Panèl Dèyè

The rear panel provides connectivity options including the power input, USB host and device ports, LAN port for network connectivity, and a VGA port for external display output.

5. Enstalasyon

Follow these steps to set up your OWON SDS6062 oscilloscope for initial use.

5.1 Konekte pouvwa

  1. Ensure the oscilloscope is turned off.
  2. Connect the supplied power cord to the power input on the rear panel of the oscilloscope.
  3. Branche lòt bout kòd kouran an nan yon priz kouran AC ki gen koneksyon ak tè.

5.2 Konekte Sond yo

  1. Align the BNC connector of the probe with the CH1 or CH2 input on the front panel.
  2. Push and twist the connector clockwise until it locks into place.
  3. Attach the probe ground clip to the ground terminal of the circuit under test.
  4. Set the probe attenuation switch (e.g., 1X or 10X) to match the setting on the oscilloscope's input channel menu.

5.3 Premye pouvwa-sou

  1. Peze bouton pouvwa a ki sitiye sou panèl la devan.
  2. The oscilloscope will perform a self-test and display the startup screen.
  3. After startup, it is recommended to perform a probe compensation adjustment (refer to Section 7.3).

6. Fonksyonman Osiloskop la

This section covers basic operation and common functions of the SDS6062.

6.1 Mezi Debaz yo

To display a signal:

  1. Konekte yon sous siyal sou CH1 oubyen CH2 a avèk yon sond.
  2. Peze a AUTOSET button. The oscilloscope will automatically adjust vertical, horizontal, and trigger settings to display a stable waveform.
  3. Ajiste a VOLTS/DIV knob to change the vertical scale (voltage pou chak divizyon).
  4. Ajiste a SEC/DIV knob to change the horizontal scale (time per division).
  5. Use the vertical and horizontal POZISYON knobs to move the waveform on the screen.

6.2 Sistèm Deklanchè

The trigger system stabilizes repetitive waveforms and captures single-shot events.

  • Nivo deklanche: Sèvi ak la NIVO DEKLANCHMAN bouton pou mete volim nantage level at which the trigger occurs.
  • Deklanche Mode: Access the trigger menu to select modes like Edge, Pulse, Video, or Slope.
  • Sous deklanche: Select the input channel (CH1, CH2, EXT, AC Line) that will be used for triggering.

6.3 Fonksyon Mezi

The SDS6062 offers various automatic measurement functions.

  • Peze a MEZI button to display the measurement menu.
  • Select desired measurements such as Vpp, Vmax, Vmin, Freq, Period, Rise Time, etc.

6.4 Connectivity (LAN and VGA)

  • LAN: Connect an Ethernet cable to the LAN port on the rear panel to connect the oscilloscope to a network. This allows for remote control and data transfer using compatible software.
  • VGA: Use the VGA port to connect an external monitor or projector for larger display of waveforms, useful for presentations or collaborative work.

7. Antretyen

Bon antretyen asire lonjevite ak presizyon osiloskop ou a.

7.1 Netwayaj

Netwaye enstriman an regilyèman avèk yon twal mou,amp cloth. Do not use abrasive cleaners or solvents that could damage the casing or screen. Ensure the device is powered off and unplugged before cleaning.

7.2 Depo

When not in use, store the oscilloscope in a dry, dust-free environment, away from extreme temperatures and direct sunlight. Use the original packaging or a suitable carrying case for protection during transport.

7.3 Probe Compensation Adjustment

Probe compensation should be adjusted to match the oscilloscope's input characteristics. This ensures accurate measurements.

  1. Connect the probe to CH1 and attach the probe tip to the probe compensation output (usually a square wave test point on the front panel).
  2. Attach the probe ground clip to the ground terminal.
  3. Peze AUTOSET.
  4. Use the supplied probe adjust pen to turn the trimmer screw on the probe until the square wave displayed on the screen has flat top and bottom edges (no overshoot or undershoot).

NAN. Depanaj

Seksyon sa a bay solisyon pou pwoblèm komen ou ka rankontre.

  • Pa gen ekspozisyon: Check power connection, ensure the power button is pressed. Adjust screen brightness if necessary.
  • No Waveform: Verify probe connection to the input channel and the circuit under test. Ensure the signal source is active. Press AUTOSET. Check vertical and horizontal scale settings.
  • Fòm Vag Enstab: Adjust the trigger level. Check trigger mode and source settings. Ensure the signal is within the oscilloscope's bandwidth.
  • Mezi ki pa kòrèk: Perform probe compensation adjustment (Section 7.3). Ensure probe attenuation settings match the oscilloscope.
  • Aparèy pa reponn: Try restarting the oscilloscope. If the issue persists, contact technical support.

9. Espesifikasyon

Technical specifications for the OWON SDS6062 Digital Storage Oscilloscope.

ParamètSpesifikasyon
Nimewo ModèlSDS6062
Bandwidth60 MHz
Chanèl2 + 1 (External Trigger)
Sample Rate (Real-time)500 MS/s
Longè dosye10M points
Ekspozisyon8-inch Color TFT-LCD (800x600)
EntèfasUSB Host, USB Device, LAN, VGA
AutoScale FunctionWi
ManifaktiOWON

10. Garanti ak sipò

OWON products are designed for reliability and performance. For warranty information, please refer to the warranty card included with your product or visit the official OWON website. For technical support, troubleshooting assistance, or service inquiries, please contact your local OWON distributor or the OWON customer service department. Keep your purchase receipt as proof of purchase for warranty claims.