Zoeller 807-0001

Zoeller Shark Model 807-0001 Residential Grinder Pump User Manual

Model: 807-0001 | Brand: Zoeller

Entwodiksyon

This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of your Zoeller Shark Model 807-0001 Residential Grinder Pump. Please read this manual thoroughly before attempting to install or operate the pump. Retain this manual for future reference.

The Zoeller Shark Model 807-0001 is a 1 HP, 115V residential grinder pump designed for handling wastewater and effluent in residential applications. It features a robust grinding mechanism to reduce solids into a fine slurry, allowing for discharge through small diameter piping.

Enfòmasyon sou Sekirite

WARNING: Risk of electric shock. This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.

Enstalasyon ak Enstalasyon

Proper installation is crucial for the longevity and performance of your grinder pump. Consult a qualified professional for installation if you are unsure.

Debalaj ak enspeksyon

Carefully remove the pump from its packaging. Inspect for any visible damage that may have occurred during shipping. Report any damage to your supplier immediately.

Zoeller Shark Model 807-0001 Residential Grinder Pump

Figure 1: Zoeller Shark Model 807-0001 Residential Grinder Pump. This image shows the complete pump unit with its float switch mechanism.

Location and Sump Requirements

Koneksyon kanalizasyon

Koneksyon elektrik

Enstriksyon Operasyon

Once installed and connected, the Zoeller Shark Model 807-0001 operates automatically via its float switch.

Inisyal Start-up

  1. Ensure all piping and electrical connections are secure.
  2. Slowly fill the sump with water to activate the float switch.
  3. Observe the pump for proper operation: it should turn on, pump down the water, and then turn off.
  4. Check for any leaks in the discharge piping.

Operasyon nòmal

The pump will activate when the water level rises to the "on" level set by the float switch and will continue to run until the water level drops to the "off" level. The grinding mechanism processes solids before pumping.

Zoeller Shark Grinder Pump Impeller and Grinding Plate

Figi 2: Close-up view of the Zoeller Shark Grinder Pump's impeller and grinding plate. This mechanism is responsible for reducing solids in wastewater.

Antretyen

Regular maintenance helps ensure reliable operation and extends the life of your pump.

Routine Checks (Monthly)

Annual Inspection (Professional Recommended)

ATANSYON: Toujou dekonekte kouran an anvan ou fè nenpòt antretyen oswa enspeksyon.

Depanaj

This section provides solutions to common issues. For problems not listed, contact customer support.

PwoblèmKòz posibSolisyon
Ponp pa kouriNo power; tripped breaker; faulty float switch; motor overload.Check power supply and breaker. Inspect float switch for obstruction. Reset thermal overload if present.
Ponp kouri kontinyèlmanStuck float switch; check valve failure; discharge line blockage.Clear float switch. Inspect/replace check valve. Clear discharge line.
Pump runs but no water is dischargedAir lock; clogged impeller/grinder; discharge line blockage.Vent air from pump. Clear impeller/grinder. Clear discharge line.
Twòp bri oswa VibrationDebri nan ponp lan; kousinen ki ize; move enstalasyon.Disconnect power and inspect for debris. Contact service professional for worn parts.

Espesifikasyon

KarakteristikDetay
Nimewo Modèl807-0001
MakZoeller
Puissance1 HP
Voltage115 Volts
Sous pouvwaAC/DC
Pousantaj maksimòm koule45 galon pou chak minit
Pwa atik65 liv
Dimansyon pwodwi17.25"L x 8.91"L x 17.25"H
MateryèlNerjaveèi asye

Enfòmasyon sou Garanti

Zoeller Company products are warranted against defects in material and workmanship for a period specified by the manufacturer from the date of purchase. Specific warranty terms and conditions may vary. Please refer to the official Zoeller Company warranty statement provided with your product or visit the manufacturer's websit pou enfòmasyon detaye.

Note: Improper installation, unauthorized repairs, or misuse of the product may void the warranty.

Sipò pou Kliyan

For technical assistance, replacement parts, or warranty claims, please contact Zoeller Customer Support.

Dokiman ki gen rapò - 807-0001

Preview Ponp Moulen Zoeller Shark 803, 805, 807 Fractional HP - Seri Rezidansyèl
Eksplore ponp moulen Zoeller Shark Series fraksyon puisans (modèl 803, 805, 807) ki fèt pou aplikasyon difisil pou dlo egou rezidansyèl yo. Karakteristik yo enkli konstriksyon an fè fonn, Teknoloji Kouto Tri Slice®, ak opsyon otomatik/ki pa otomatik. View done pèfòmans ak konparezon modèl.
Preview Zoeller Shark Series Fractional HP Grinder Pumps Models 803/805/807 Technical Data Sheet
Detailed technical specifications, performance curves, and model comparison for Zoeller's Shark Series Fractional HP Grinder Pumps (Models 803, 805, 807). These cast iron pumps are designed for residential sewage applications handling 'flushable' materials.
Preview Zoeller 803/805/807 Grinder Pumps Installation and Service Instructions
Comprehensive installation, service, and warranty information for Zoeller 803, 805, and 807 Grinder Pumps. Includes pre-installation checklists, safety warnings, installation recommendations, wiring diagrams, repair procedures, performance data, and troubleshooting.
Preview Ponp Moulen Zoeller 803/805/807: Enstriksyon Enstalasyon ak Sèvis
Gid konplè pou enstalasyon, sèvis, ak garanti pou ponp moulen sibmèsib Zoeller seri 803, 805, ak 807 yo. Gen ladan lis verifikasyon pre-enstalasyon, avètisman sekirite, dyagram fil elektrik, pwosedi reparasyon, ak done pèfòmans.
Preview Sistèm Ponp Puiman Pre-asanble Zoeller Seri 900 - Enstalasyon Fasil
Dekouvri sistèm ponp puisard Zoeller 900 Seri yo ki deja monte, ki fèt pou yon enstalasyon rapid e fasil. Karakteristik yo enkli yon switch flote otomatik, yon ponp fè fonn dirab, ak plizyè kalite...asin options for residential and commercial use. Learn about model specifications and performance.
Preview Fich Done Teknik Ponp Moulen Zoeller Modèl 840 & 841 Shark Doub Seal
Espesifikasyon teknik konplè, done pèfòmans, enfòmasyon elektrik, ak konpozan sistèm pou ponp Zoeller Modèl 840 ak 841 Shark Dual Seal Grinder, ki detaye karakteristik, dimansyon, ak kapasite operasyonèl yo.