Tektronix TPP0500B

Tektronix TPP0500B Oscilloscope Probe User Manual

This manual provides essential information for the safe and effective use of the Tektronix TPP0500B Oscilloscope Probe.

1. Entwodiksyon

The Tektronix TPP0500B is a high-bandwidth, general-purpose passive voltage probe designed for precise signal acquisition. It is compatible with Tektronix MDO3000, MDO4000, MSO/DPO5000, and 5 Series MSO Series oscilloscopes. This probe offers up to 1 GHz of analog bandwidth with less than 3.9 pF of capacitive loading, ensuring accurate high-speed passive probing and minimal impact on the circuit under test.

2. Karakteristik kle

  • 1 GHz Bandwidth: Capable of accurately measuring high-frequency signals.
  • <4 pF Input Capacitance: Minimizes loading effects on the circuit under test.
  • 10X Attenuation Factor: Extends the dynamic range of the oscilloscope.
  • 300 V CAT II Input Voltage: Suitable for a wide range of applications.
  • Compact Probe Head: Facilitates probing small-geometry circuit elements.

3. Enstriksyon Enstalasyon

Follow these steps to properly set up your TPP0500B oscilloscope probe:

  1. Connect to Oscilloscope: Plug the TekVPI interface connector of the TPP0500B probe into an available TekVPI channel on your compatible Tektronix oscilloscope. Ensure a secure connection.
  2. Attach Ground Lead: Connect the ground lead (typically with an alligator clip) from the probe to the ground reference of the circuit you are testing. A stable ground connection is crucial for accurate measurements.
  3. Select Probe Tip: Choose the appropriate probe tip for your application. The probe typically comes with various tips for different connection requirements.
  4. Konpansasyon Sond: Before taking measurements, compensate the probe to match the input impedance of your oscilloscope. Connect the probe tip to the oscilloscope's probe compensation output (usually a square wave signal) and the ground lead to the compensation ground. Adjust the compensation trimmer on the probe (if present) until the square wave displayed on the oscilloscope is flat-topped, without overshoot or undershoot. Refer to your oscilloscope's manual for specific compensation procedures.
Tektronix TPP0500B Oscilloscope Probe with accessories including probe tip, ground lead, and color rings.

This image displays the Tektronix TPP0500B oscilloscope probe, featuring its main body, flexible cable, and various accessories. These accessories typically include a removable probe tip, a ground lead with an alligator clip, and colored identification rings for channel differentiation. The probe is designed for connecting to an oscilloscope to measure electrical signals.

4. Operasyon Enstriksyon

Once the probe is set up and compensated, you can begin taking measurements:

  • Connect to Test Point: Carefully connect the probe tip to the desired test point on your circuit. Ensure a firm and stable connection.
  • Observe Waveform: Adjust the oscilloscope's vertical and horizontal settings to display the waveform clearly. The 10X attenuation factor means the voltage displayed on the oscilloscope will be one-tenth of the actual voltage at the probe tip. Most modern oscilloscopes with TekVPI interfaces will automatically detect the probe and adjust the vertical scaling accordingly.
  • Prekosyon sekirite: Toujou okouran de voltage limits of the probe (300 V CAT II). Do not exceed these limits. Ensure proper grounding of both the oscilloscope and the circuit under test to prevent electrical shock and ensure accurate readings. Avoid touching live circuit components with your hands or other conductive materials while probing.

5. Antretyen

Proper care and maintenance will extend the life and accuracy of your TPP0500B probe:

  • Netwayaj: Use a soft, dry cloth to clean the exterior of the probe. If necessary, a cloth lightly dampened with isopropyl alcohol can be used. Avoid using harsh chemicals or abrasive materials. Ensure no liquid enters the probe body or connectors.
  • Depo: Store the probe in a clean, dry environment, preferably in its original packaging or a protective case, when not in use. Avoid exposing it to extreme temperatures, humidity, or direct sunlight.
  • Manyen: Handle the probe carefully. Do not bend the cable sharply or apply excessive force to the probe tip or connector. Avoid dropping the probe.
  • Enspeksyon: Periodically inspect the probe cable, connectors, and tip for any signs of damage, such as cuts, cracks, or bent pins. Do not use a damaged probe.

NAN. Depanaj

If you encounter issues with your TPP0500B probe, consider the following:

  • No Signal or Weak Signal:
    • Ensure the probe is securely connected to both the oscilloscope and the circuit under test.
    • Verify the ground lead is properly connected.
    • Check the oscilloscope's input channel settings and vertical scale.
    • Confirm the circuit under test is powered and functioning correctly.
  • Distorted Waveform:
    • Perform probe compensation as described in the Setup section.
    • Check for damaged probe tips or cables.
    • Ensure the probe's bandwidth is sufficient for the signal frequency.
  • Kòrèk Voltage Lekti:
    • Verify the oscilloscope's vertical scale is correctly calibrated and set for a 10X probe. TekVPI probes usually auto-detect.
    • Ensure the probe is properly compensated.

If problems persist, contact Tektronix customer support.

7. Espesifikasyon

SpesifikasyonValè
Nimewo ModèlTPP0500B
Bandwidth1 GHz
Faktè atténuation10X
Antre kapasite<4 pF
Rezistans Antre10 MΩ (when terminated into 1 MΩ oscilloscope input)
Maksimòm Antre Voltage300 V CAT II
Tèt SondeCompact design for small-geometry circuits
EntèfasTekVPI
ManifaktiTektronix
Pwa atik1 liv (apeprè)

8. Enfòmasyon sou Garanti

The Tektronix TPP0500B Oscilloscope Probe is covered by a manufacturer's warranty. For detailed information regarding warranty terms, duration, and conditions, please refer to the official Tektronix websit la oswa kat garanti ki vini ak pwodwi ou a. Kenbe prèv acha ou pou reklamasyon garanti.

9. Sipò pou Kliyan

For technical assistance, service, or further inquiries regarding your Tektronix TPP0500B probe, please contact Tektronix customer support:

  • Websit: Vizite ofisyèl la Tektronix websit for product documentation, FAQs, and support resources.
  • Enfòmasyon pou kontakte: Refer to the 'Contact Us' section on the Tektronix websit la pou nimewo telefòn ak opsyon sipò imèl espesifik pou rejyon ou an.

Dokiman ki gen rapò - TPP0500B

Preview Tektronix TPP0250 and TPP0500B 10X Passive Probes: Instructions and Specifications
User instructions and technical specifications for Tektronix TPP0250 (250 MHz) and TPP0500B (500 MHz) 10X passive oscilloscope probes, covering setup, operation, accessories, and safety.
Preview Tektronix Passive Voltage Probes TPP1000, TPP0500B, TPP0502, TPP0250 - Product Specifications
Detailed specifications, features, applications, and accessories for Tektronix TPP1000, TPP0500B, TPP0502, and TPP0250 passive voltage probes. High bandwidth, low capacitance probes designed for Tektronix oscilloscopes.
Preview Manyèl Enstriksyon Sond Pasif Tektronix P6105A 100 MHz 10X
Manyèl enstriksyon konplè pou sond pasif Tektronix P6105A 100 MHz 10X la, ki detaye karakteristik li yo, espesifikasyon li yo, enstalasyon li, operasyon li, sekirite li ak antretyen li.
Preview Manyèl Enstriksyon Sond Tektronix P6006 la
Manyèl enstriksyon pou sond pasif Tektronix P6006 la, ki detaye espesifikasyon li yo, karakteristik li yo, pwosedi konpansasyon yo, koub derating yo, ak pyès ranplasabl yo.
Preview Tektronix P5102 100 MHz High-Voltage Manyèl Enstriksyon Sonde
Comprehensive instruction manual for the Tektronix P5102 100 MHz High-Voltage Probe, covering safety, operation, adjustment, verification, maintenance, and specifications. Includes detailed guidance for high-voltage mezi.
Preview P6339A 500 MHz Buffered Passive Probe Instruction Manual
Comprehensive instruction manual for the Tektronix P6339A 500 MHz Buffered Passive Probe, detailing its features, operation, specifications, safety precautions, adjustment procedures, and maintenance.