1. Entwodiksyon
The Vortice CA 200 WE D E is a high-performance radial duct fan designed for external wall mounting. This unit is engineered to provide efficient air extraction or supply in various environments, offering robust construction and reliable operation. It features a nominal diameter of 200 mm, a maximum power consumption of 100 Watts, and a maximum air flow of 680 m³/h. The fan is also rated IPX5 for protection against jet water, making it suitable for outdoor installation.
This manual contains important information regarding the safe installation, operation, and maintenance of your Vortice fan. Please read it thoroughly before using the product and keep it for future reference.
2. Enfòmasyon sou Sekirite
Always adhere to the following safety guidelines to prevent injury and damage to the unit:
- Enstalasyon ak koneksyon elektrik yo dwe fèt pa pèsonèl kalifye, dapre règleman ak estanda lokal yo.
- Ensure the power supply is disconnected before any installation, maintenance, or cleaning procedures.
- Do not operate the fan if any part is damaged or if the casing ouvè.
- Kenbe men, cheve, ak rad ki lach lwen pati k ap deplase.
- Aparèy sa a pa fèt pou itilize pa moun (ki gen ladan timoun) ki gen kapasite fizik, sansoryèl oswa mantal redwi, oswa ki pa gen eksperyans ak konesans, sof si yo te ba yo sipèvizyon oswa enstriksyon konsènan itilizasyon aparèy la pa yon moun ki responsab sekirite yo.
- Pa bloke antre oswa priz lè yo.
- The fan is designed for air ventilation only. Do not use it to extract flammable, explosive, or corrosive gases.
3. Enstalasyon ak Enstalasyon
The Vortice CA 200 WE D E fan is designed for external wall mounting. Proper installation is crucial for optimal performance and safety.
3.1 Debake
Carefully remove the fan from its packaging. Inspect the unit for any signs of damage during transit. Report any damage to your supplier immediately.
3.2 Kote montaj
Choose a suitable external wall location that allows for proper ducting and access for maintenance. Ensure the wall material can support the weight of the unit.

Figure 3.1: Diagram illustrating typical installation scenarios for the fan, including residential and commercial applications, showing air flow paths.
3.3 Enstalasyon mekanik
- Mark the drilling points on the wall using the fan's mounting holes as a template.
- Drill holes and insert appropriate wall plugs (not supplied).
- Secure the fan to the wall using suitable screws, ensuring it is level and firmly attached.
- Connect the ductwork to the fan's inlet/outlet. Ensure all connections are airtight to prevent air leakage.

Figi 3.2: Devan view of the Vortice external wall radial duct fan, showing its compact design and the Vortice logo.
3.4 Koneksyon elektrik
Tout travay elektrik dwe fèt pa yon elektrisyen kalifye.
- Ensure the main power supply is switched off at the circuit breaker.
- Open the electrical connection box on the fan unit.
- Connect the power supply cable to the terminal block inside the fan, following the wiring diagram provided with the unit. Ensure proper grounding.
- Fèmen bwat koneksyon an byen.
- Optional speed controllers and sensors (sold separately) can be integrated into the wiring as per their respective manuals.
4. Operasyon Enstriksyon
Once installed and electrically connected, the Vortice CA 200 WE D E fan is ready for operation.
4.1 Limen/Etenyen
Switch on the main power supply to the fan. The fan will begin operation. To turn off the fan, switch off the power supply.
4.2 Speed Control (Optional)
If an optional speed controller has been installed, refer to its specific instructions for adjusting the fan's airflow and speed. The fan's performance can be optimized based on ventilation requirements.
5. Antretyen
Regular maintenance ensures the longevity and efficient operation of your Vortice fan. Always disconnect the power supply before performing any maintenance.
5.1 Netwaye fanatik la
Periodically inspect the fan blades and casing for dust and debris accumulation. Clean with a soft, damp twal. Pa sèvi ak pwodui netwayaj abrazif oswa solvang.
5.2 Inspecting Connections
Occasionally check all mechanical and electrical connections to ensure they remain secure. Tighten any loose screws or terminals.

Figi 5.1: Anwo-anba view of the Vortice fan unit, showing the internal components and the duct connection area, which should be kept clear of debris.
NAN. Depanaj
If you encounter issues with your Vortice fan, refer to the following table for common problems and solutions.
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Fanatik pa kòmanse | Pa gen ekipman pou pouvwa Koneksyon elektrik ki lach Fòt motè | Check power switch and circuit breaker Verify all electrical connections (ensure power is off) Kontakte pèsonèl sèvis kalifye yo |
| Diminye koule lè a | Blocked inlet/outlet Lam fanatik sal Duct leakage | Netwaye nenpòt obstak Netwaye lam fanatik yo Check duct connections for leaks |
| Bri/vibrasyon dwòl | Montaj ki lach Debri nan vantilatè a Motor bearing issue | Sere boulon vis aliye yo Inspect and clean fan interior Kontakte pèsonèl sèvis kalifye yo |
If the problem persists after attempting these solutions, please contact qualified service personnel or Vortice customer support.
7. Espesifikasyon
Technical specifications for the Vortice CA 200 WE D E Radial Duct Fan:
| Atribi | Valè |
|---|---|
| Mak | Toubiyon |
| Nimewo Modèl | 8010300160894 |
| Dyamèt nominal | 200 mm |
| Max. Konsomasyon pouvwa | 100 Watt |
| Maks. Flow Air | 680 m³/h |
| Evalyasyon Pwoteksyon Ingress (IP). | IPX5 (Jet Water Protected) |
| Koulè | Blan |
| Materyèl | Metal |
| ASIN | B00VWBIDJ6 |
| Premye disponib sou Amazon.de | 21 fevriye 2019 |
8. Garanti ak sipò
For warranty information, please refer to the documentation provided at the time of purchase or contact your retailer. Vortice products are designed for durability and performance. In case of technical issues or for further assistance, please contact Vortice customer support or an authorized service center.