FAAC XBAT

FAAC X-BAT 24V Emergency Battery Pack Instruction Manual

Model: XBAT (Part No. 390923)

1. Entwodiksyon

This instruction manual provides essential information for the safe and effective installation, operation, and maintenance of your FAAC X-BAT 24V Emergency Battery Pack. This device is designed to provide emergency power to compatible FAAC automation systems during mains power outages, ensuring continued functionality of gates or barriers.

Please read this manual thoroughly before proceeding with installation or use. Keep this manual for future reference.

2. Enstriksyon Sekirite

Toujou obsève prekosyon sekirite sa yo pou evite blesi oswa domaj nan pwodwi a ak ekipman ki asosye avèk li a:

3. Pwodwi souview

The FAAC X-BAT 24V Emergency Battery Pack is a compact unit designed to integrate seamlessly with compatible FAAC gate and barrier automation systems. It provides a reliable backup power source, ensuring your system remains operational during electrical outages.

FAAC X-BAT 24V Emergency Battery Pack

Figure 1: FAAC X-BAT 24V Emergency Battery Pack. This image shows the compact, rectangular battery pack with a clear casing revealing internal green components and circuitry. A small metal screw is visible on the top right corner.

The unit typically consists of a sealed battery enclosure with connection terminals for integration into the control board of the automation system.

4. Enstalasyon ak Enstalasyon

Installation of the X-BAT battery pack should be performed by a qualified technician following the specific instructions provided with your FAAC automation system's control unit. General steps include:

  1. Dekoneksyon pouvwa: Ensure the main power supply to the FAAC control unit is completely disconnected before beginning installation.
  2. Montaj: Securely mount the X-BAT battery pack in the designated compartment within the FAAC control unit enclosure, or in a suitable, protected location as specified by your system's manual.
  3. Koneksyon: Connect the battery pack's terminals to the corresponding battery input terminals on the FAAC control board. Pay close attention to polarity (positive to positive, negative to negative) to avoid damage. Refer to your FAAC control unit's wiring diagram.
  4. Inisyal chaj: Once connected, restore mains power to the FAAC control unit. The X-BAT battery pack will begin charging automatically. Allow sufficient time for the battery to fully charge before relying on its emergency power function. The initial charge time can vary.
  5. Tès fonksyonalite: After initial charging, simulate a power outage (e.g., by temporarily disconnecting mains power to the control unit) to verify that the automation system operates correctly on battery power.

5. Prensip Operasyon yo

The FAAC X-BAT 24V Emergency Battery Pack operates as an automatic backup power supply. When mains power is present, the battery pack remains in a charged state, ready for use. In the event of a power failure, the control unit automatically switches to the battery pack, allowing the automation system to continue functioning for a limited number of cycles or duration, depending on the system's power consumption and the battery's charge level.

Once mains power is restored, the battery pack will automatically recharge, preparing for the next potential outage.

6. Antretyen

Proper maintenance extends the life of your battery pack and ensures reliable operation:

NAN. Depanaj

If your FAAC X-BAT 24V Emergency Battery Pack is not performing as expected, consider the following:

PwoblèmKòz posibSolisyon
System does not operate during power outage.Battery pack not charged, faulty connections, battery pack has reached end of life.
  • Verify mains power is restored and allow sufficient charging time.
  • Check all connections for proper polarity and secure fit.
  • If the battery pack is old (e.g., 1-2 years or more), it may need replacement.
Battery pack does not hold charge.Battery degradation, internal fault.This is a common issue reported by users. The battery pack may have reached its end of life prematurely. Replacement is typically required.
Physical damage to the unit.Impact during shipping or installation.If the unit is physically damaged (e.g., cracked casing), it should not be used and may need to be replaced. Contact your supplier.

For persistent issues, consult a qualified FAAC technician or contact FAAC customer support.

8. Espesifikasyon

KarakteristikDetay
MakFAAC
ManifaktiFaac
Non modèlXBAT
Voltage24 Volt
Batri enkliNo (This refers to the individual cells, the pack is sold as a unit)
ReyabiliteRechargeable
ASINB00LLEO6Y0
Premye Dat ki disponib12 jen 2015

9. Garanti ak sipò

For specific warranty terms and conditions, please refer to the documentation provided at the time of purchase or contact your FAAC product supplier. Warranty coverage typically applies to manufacturing defects and may not cover normal wear and tear or damage resulting from improper installation or use.

For technical support, spare parts, or service, please contact your authorized FAAC dealer or visit the official FAAC websit pou jwenn enfòmasyon kontak nan rejyon ou an.

Dokiman ki gen rapò - XBAT

Preview Manyèl Enstalasyon ak Operasyon Kat Elektwonik FAAC E034
Gid konplè pou enstalasyon, konfigirasyon, ak antretyen kat elektwonik FAAC E034 pou sistèm automatisation baryè. Li kouvri espesifikasyon teknik, karakteristik sekirite, ak akseswa.
Preview Twous Batri Sekou FAAC B680H: Enstalasyon, Fil elektrik, ak Operasyon
Yon gid konplè pou Twous Batri Sekou FAAC B680H la, ki kouvri konpozan li yo, etap enstalasyon yo, enstriksyon fil elektrik yo, detay operasyonèl yo, ak garanti limite pou sistèm operatè baryè FAAC yo.
Preview FAAC E034 Steuereinheit: Installations- und Bedienungsanleitung
Diese detaillierte Anleitung für die FAAC E034 Steuereinheit bietet umfassende Informationen zur Installation, Konfiguration, Sicherheit und Wartung von automatisierten Toranlagen. Erfahren Sie mehr über technische Spezifikationen, Zubehör wie BUS 2easy und Funkmodule.
Preview FAAC B614 & B680H Gid Enstalasyon Twous Atikle Beam
Gid konplè pou enstalasyon ak asanblaj pou sistèm baryè ak travès atikile FAAC B614 ak B680H. Gen ladan lis pyès, dimansyon, ak enstriksyon detaye.
Preview Manyèl Enstalasyon ak Operasyon Baryè Otomatik FAAC 615BPR
Gid konplè pou enstalasyon, operasyon, ak antretyen sistèm baryè otomatik FAAC 615BPR la, ki gen ladan espesifikasyon teknik, avètisman sekirite, ak depanaj.
Preview FAAC S450H 24V Hydraulic Swing Gate Operator Manual
Comprehensive installation and user manual for the FAAC S450H 24V Hydraulic Swing Gate Operator. Includes safety instructions, technical specifications, installation guides, programming, and troubleshooting.