1. Entwodiksyon
This manual provides essential instructions for the safe and effective operation, maintenance, and troubleshooting of your Fluke 362 200A AC/DC Clamp Meter. Please read this manual thoroughly before using the device to ensure proper functionality and safety.
The Fluke 362 is a compact and versatile clamp meter designed for measuring AC and DC current up to 200A, AC and DC voltage up to 600V, resistance up to 3000 Ω, and continuity. Its ergonomic design and robust construction make it suitable for various electrical measurement tasks.
2. Enfòmasyon sou Sekirite
WARNING: To prevent possible electrical shock, fire, or personal injury, read all safety information before you use the product.
- Toujou respekte kòd sekirite lokal ak nasyonal yo.
- Do not use the meter if it is damaged or operating abnormally.
- Asire w ke switch fonksyon an nan bon pozisyon pou mezi w ap fè a.
- Pa aplike plis pase rated voltage, jan yo make sou kontè a, ant tèminal yo oswa ant nenpòt tèminal ak tè tè a.
- The Fluke 362 is rated for CAT III 600 V. This rating indicates suitability for measurements in distribution boards, circuit breakers, wiring, including cables, bus-bars, junction boxes, switches, and socket outlets in the fixed installation, and industrial use equipment.
- Pran prekosyon lè w ap travay ak voltages above 30 V AC RMS, 42 V peak, or 60 V DC. These voltages poze yon danje chòk.
- Remove test leads from the circuit before opening the battery cover.
- Ranplase pil yo lè endikatè pil fèb la parèt pou asire lekti yo egzak.
3. Pwodwi souview
The Fluke 362 clamp meter features a robust design for reliable performance in various environments. Familiarize yourself with its components:

Figi 1: Devan view of the Fluke 362 Clamp Meter, showing the display, function dial, jaw, and buttons.

Figure 2: The Fluke 362 Clamp Meter held in a gloved hand, illustrating its compact size and ergonomic design for single-hand operation.
Konpozan kle:
- Kouran Clamp Machwa: For non-contact AC/DC current measurements. Features an 18 mm triangular jaw for access in tight spaces.
- Fonksyon Dial: Rotary switch to select measurement functions (AC/DC current, AC/DC voltage, rezistans, kontinwite).
- Ekspozisyon LCD: Large, easy-to-read digital display for measurement results.
- Bouton HOLD: Li bloke lekti aktyèl la sou ekran an.
- ZERO bouton: Used to clear the display for DC current measurements, compensating for any offset.
- Antre Tèminal: Pou konekte fil tès pou volimtage, resistance, and continuity measurements.
Karakteristik kle:
- 200 A AC/DC current measurement capability.
- 600 V AC/DC voltagkapasite mezi e.
- 3000 Ω resistance range.
- Continuity detection with audible indicator.
- Zero function for accurate DC measurements.
- Data hold function to capture readings.
- Large, clear display for easy viewing.
- Compact and lightweight design for one-hand operation.
- CAT III 600 V safety rating.
4. Enstalasyon
4.1 Enstalasyon batri
The Fluke 362 is battery-powered. Although batteries are not included with all packages, they are required for operation. To install or replace batteries:
- Ensure the meter is turned OFF and no test leads are connected.
- Jwenn kouvèti konpatiman pil la sou dèyè mèt la.
- Sèvi ak yon tournevis pou dekole vis(yo) ki kenbe kouvèti a.
- Remove the cover and insert the required batteries, observing correct polarity (+/-).
- Remèt kouvèti batri a epi sere vis la(yo).
4.2 Koneksyon Plon Tès la
Pou voltage, resistance, and continuity measurements, connect the test leads to the input terminals:
- Insert the black test lead into the “COM” (common) terminal.
- Insert the red test lead into the “VΩ” (voltage/resistance) terminal.
5. Operasyon Enstriksyon
5.1 Limen/Etenyen
Rotate the function dial from the “OFF” position to any desired measurement function to power on the meter. To power off, rotate the dial back to the “OFF” position.
5.2 Seleksyon Fonksyon
Use the rotary function dial to select the desired measurement mode (e.g., A∼ for AC current, A— for DC current, V∼ for AC voltage, V— for DC voltage, Ω for resistance, or continuity).
5.3 Mezi Kouran AC/DC (Clamp)
To measure current using the clamp machwè:
- Rotate the function dial to A∼ (AC current) or A— (DC current).
- For DC current measurements, press the “ZERO” button to clear any offset before clamping.
- Louvri cl laamp machwè a lè w peze deklanche a.
- Enclose only one conductor within the jaw. Ensure the jaw is fully closed.
- Li valè aktyèl la sou ekran an.
5.4 AC/DC Voltage Mezi
Pou mezire voltage:
- Konekte fil tès yo jan sa dekri nan Seksyon 4.2 la.
- Rotate the function dial to V∼ (AC voltage) or V— (DC voltagak).
- Connect the test probes in parallel to the circuit or component you wish to measure.
- Li voltage valè sou ekspozisyon an.
5.5 Mezi rezistans
Pou mezire rezistans:
- Asire w ke sikwi a oswa konpozan an pa gen enèji anvan ou mezire rezistans lan.
- Konekte fil tès yo jan sa dekri nan Seksyon 4.2 la.
- Rotate the function dial to Ω (resistance).
- Konekte sond tès yo atravè konpozan an.
- Li valè rezistans nan ekspozisyon an.
5.6 Tès kontinwite
Pou fè yon tès kontinite:
- Asire w ke sikwi a oswa konpozan an pa gen enèji.
- Konekte fil tès yo jan sa dekri nan Seksyon 4.2 la.
- Rotate the function dial to the continuity position (often shared with resistance, indicated by a speaker icon).
- Connect the test probes across the component or wire.
- The meter will emit an audible tone if continuity is detected (resistance below a certain threshold).
5.7 Zero Function (DC Measurements)
The “ZERO” button is primarily used for DC current measurements. Before taking a DC current reading, with the clamp jaw open and no conductor inside, press the “ZERO” button to eliminate any residual offset and ensure accurate readings.
5.8 Fonksyon kenbe done
Press the “HOLD” button to freeze the current reading on the display. This is useful for taking readings in hard-to-see locations. Press “HOLD” again to release the reading and return to live measurement.
6. Antretyen
6.1 Netwayaj
To clean the meter, wipe it with a damp twal ak yon savon dou. Pa sèvi ak pwodui abrazif oswa solvang. Asire w ke mèt la byen sèk anvan w itilize li.
6.2 Ranplasman batri
When the low battery indicator appears on the display, replace the batteries promptly to maintain measurement accuracy. Refer to Section 4.1 for battery installation instructions.
6.3 Depo
If the meter is not used for an extended period, remove the batteries to prevent leakage and damage. Store the meter in a dry, cool environment, away from direct sunlight and extreme temperatures.
NAN. Depanaj
If you encounter issues with your Fluke 362, refer to the table below for common problems and solutions:
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Meter does not power on or display is blank. | Pil ki mouri oswa ki mal enstale. | Tcheke polarite pil yo oubyen ranplase pil yo. |
| Lekti ki pa kòrèk. | Low battery, incorrect function selected, external interference, or un-zeroed DC current. | Replace batteries, select correct function, move away from strong electromagnetic fields, or use the ZERO function for DC current. |
| Continuity tone is too low or inaudible. | Noisy work environment. | Relocate to a quieter area or rely on the visual display for continuity indication. |
| “OL” (Overload) displayed. | Measurement exceeds the meter’s range. | Ensure the measurement is within the specified range for the selected function. |
If the problem persists after attempting these solutions, contact Fluke customer support.
8. Espesifikasyon
| Paramèt | Spesifikasyon |
|---|---|
| Mak | Fluke |
| Modèl | 362 |
| AC Range Kouran | 200 A |
| DC Kouran Range | 200 A |
| AC Voltage Range | 600 V |
| DC Voltage Range | 600 V |
| Ranje Rezistans | 3000 Ω |
| Rating sekirite | CAT III 600 V |
| Ouvèti machwè | 18 mm |
| Sous pouvwa | Batri Powered |
| Dimansyon (L x W x H) | 7.87 x 1.57 x 3.94 pous |
| Pwa atik | 14.1 ons (400 gram) |
| UPC | 095969672191 |
| Nimewo Modèl | 4345498 |
9. Garanti ak sipò
Fluke products are designed for reliability and performance. For specific warranty details, please refer to the warranty card included with your product or visit the official Fluke websit la. Kenbe resi acha ou kòm prèv acha.
For technical support, service, or calibration, please contact Fluke customer service through their official website or the contact information provided in your product packaging. When contacting support, please have your model number (Fluke 362) and serial number (if applicable) ready.