FLIR MR77

FLIR MR77 Pinless Moisture Meter User Manual

Comprehensive instructions for operation and maintenance of your FLIR MR77 Moisture Meter.

1. Entwodiksyon

The FLIR MR77 Pinless Moisture Meter is a professional-grade instrument designed for accurate moisture and environmental measurements. This device combines pinless moisture detection with an external pin probe, relative humidity, and temperature sensing capabilities, making it a versatile tool for various applications.

This manual provides detailed instructions for the setup, operation, maintenance, and troubleshooting of your FLIR MR77 meter to ensure optimal performance and longevity.

2. Debalaj ak Kontni

Carefully unpack all items from the packaging. Verify that all components are present and undamaged. If any items are missing or damaged, contact your supplier immediately.

Kontni pake:

FLIR MR77 Pinless Moisture Meter

Figure 2.1: The FLIR MR77 Pinless Moisture Meter with its integrated sensor and display.

3. Enstalasyon ak Batri

3.1 Enstalasyon batri

  1. Jwenn konpatiman pil la sou dèyè mèt la.
  2. Louvri kouvèti lòj batri a.
  3. Insert the included 9V battery, observing correct polarity.
  4. Fèmen kouvèti lòj batri a byen.

3.2 Attaching Sensors

The MR77 comes with an integrated pinless sensor and ports for external sensors.

External Temperature and Relative Humidity Sensor

Figure 3.1: The external temperature and relative humidity sensor (MR01).

Pin Probe and Cable

Figure 3.2: The pin probe (MR02) for penetrating moisture measurements.

4. Operasyon Enstriksyon

4.1 Limen/Etenyen

Peze a Pouvwa button (usually located at the bottom of the device) to turn the meter on or off.

4.2 Ekspozisyon souview

Close-up of FLIR MR77 display showing moisture and temperature readings

Figure 4.1: Close-up of the MR77 display showing various readings.

The backlit LCD displays moisture readings, relative humidity, air temperature, dew point, and other relevant data. Icons indicate measurement mode, battery status, and other functions.

4.3 Mòd Mezi

The FLIR MR77 offers multiple measurement capabilities:

Hand holding FLIR MR77 performing a pinless moisture measurement

Figure 4.2: Performing a pinless moisture measurement with the FLIR MR77.

Hand holding FLIR MR77 using the integrated IR thermometer with laser pointer

Figure 4.3: Using the integrated IR thermometer with laser targeting.

4.4 Material Group Selection

The MR77 allows selection of different material groups for more accurate moisture readings. Refer to the "Material Group Reference" table in the Specifications section for details on specific materials.

FLIR MR77 display showing material group and relative humidity

Figure 4.4: The display indicating the selected material group (M09) and Relative Humidity (RH).

4.5 Depo ak Rapèl Done

Sèvi ak la STORE/RAPLE button to save and retrieve measurement data. Consult the full user manual for detailed instructions on data logging and management.

4.6 Meter Link Smartphone App

The FLIR MR77 can connect to a smartphone app via Bluetooth for enhanced data monitoring, comparison, and reporting. Download the Meter Link app from your device's app store.

Screenshots of the FLIR Meter Link smartphone app showing data logging and comparison features

Figure 4.5: The Meter Link smartphone app interface for data monitoring and comparison.

5. Antretyen

5.1 Netwayaj

Wipe the meter's exterior with a damp cloth. Do not use abrasive cleaners or solvents. Keep the sensor areas clean and free of debris.

5.2 Ranplasman Capteur

The temperature/relative humidity sensor (MR01) is field-replaceable. If readings become inaccurate or the sensor is damaged, replace it with an authorized FLIR replacement part. Refer to the full user manual for detailed replacement instructions.

5.3 Depo

Store the FLIR MR77 in a cool, dry place when not in use. Remove the battery if storing for extended periods to prevent leakage.

NAN. Depanaj

PwoblèmKòz posibSolisyon
Kontè a pa limen.Batri mouri oswa mal enstale.Check battery polarity, replace battery.
Inaccurate moisture readings.Incorrect material group selected; sensor dirty or damaged; external interference.Verify material group; clean or replace sensor; move away from strong electromagnetic fields.
Inaccurate RH/Temperature readings.Sensor dirty or damaged.Clean or replace the MR01 sensor.
Pwoblèm koneksyon Bluetooth.Meter not in pairing mode; app issues; distance from device.Ensure meter Bluetooth is active; restart app/meter; reduce distance.

For further assistance, refer to the official FLIR MR77 User Manual (PDF) or contact FLIR customer support.

7. Espesifikasyon

Espesifikasyon jeneral:

Espesifikasyon mezi:

FLIR MR77 Specifications including moisture and environmental measurements

Figure 7.1: Detailed specifications for the FLIR MR77.

Material Group Reference:

Table of Material Group Reference for FLIR MR77

Figure 7.2: Reference table for selecting appropriate material groups for moisture measurements.

This table provides common names of timbers and other materials, along with their corresponding material group numbers (e.g., Group 1-8 for timbers, Group 9 for plywood, drywall, and oriented strand board, Group 10 for brick, cement screed, and concrete, Group 11 for cement mortar, anhydrite screed, lime mortar, and plaster). Groups 10 and 11 are not specified for accuracy and should be used for reference only.

8. Enfòmasyon sou Garanti

The FLIR MR77 Pinless Moisture Meter is covered by a Garanti pou tout lavi limite. For specific terms and conditions, including details on coverage and how to make a warranty claim, please refer to the official warranty documentation provided with your product or visit the FLIR websit.

9. Sipò ak Resous Anplis

For further information, technical support, or to access the complete user manual, please use the resources below:

Dokiman ki gen rapò - MR77

Preview FLIR MR77 User Manual: Pinless Moisture Psychrometer with IR Thermometer & Bluetooth
User manual for the FLIR MR77, a pinless moisture psychrometer featuring an infrared thermometer and METERLiNK Bluetooth connectivity. Learn about its features, operation, and specifications.
Preview FLIR MR77 User's Manual: Pinless Moisture Psychrometer with IR Thermometer
User's manual for the FLIR MR77, a pinless moisture psychrometer featuring an infrared thermometer and Bluetooth METERLiNK connectivity. Learn about its features, operation, and technical specifications.
Preview Gid pou kòmanse rapid ak mèt imidite ak sond boul FLIR MR59 la
Gid demaraj rapid pou mèt imidite ak sond boul FLIR MR59 ak Bluetooth, ki kouvri konfigirasyon, operasyon, deskripsyon mèt la, bouton fonksyon, endikatè ekran, ak koneksyon Bluetooth.
Preview FLIR MR176 Imaging Moisture Meter Plus with IGM User Manual
User manual for the FLIR MR176 Imaging Moisture Meter Plus, detailing its features, operation, maintenance, and specifications. Learn how to use its thermal imaging, pinless, and pin probe moisture measurement capabilities.
Preview Twous Akseswa FLIR E60: Lis konplè akseswa kamera tèmik yo
Lis detaye sou akseswa pou kamera tèmik FLIR E60 la, ki gen ladan bwat, câbles, ekipman pouvwa, chajè, pil, kat memwa, ak dokimantasyon ki soti nan Advanced Test Equipment Corp.
Preview Fich Done Kamera Tèmik FLIR iXX Seri ki Aktive pa Aplikasyon ak LTE
Espesifikasyon ak karakteristik detaye pou Kamera Tèmik FLIR iXX-Series App-Enabled ak LTE, ki gen ladan rezolisyon IR, sansiblite, FOV, aplikasyon, ak done fizik.