Fluke 28IIEX/ETL

Manyèl Itilizatè Miltimèt Dijital True-RMS ki An Sekirite Intrinsèk Fluke 28IIEX/ETL

1. Entwodiksyon

This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of the Fluke 28IIEX/ETL Intrinsically Safe True-RMS Digital Multimeter. This device is engineered for precise electrical measurements in potentially hazardous environments, offering robust performance and advanced safety features.

2. Enfòmasyon sou Sekirite

WARNING: Read and understand all safety information before using this product. Failure to do so may result in serious injury or death.

2.1 Gid Sekirite Jeneral

  • Always use the multimeter with the specified test leads and accessories.
  • Pa sèvi ak miltimèt la si li sanble domaje oswa si li pa ap fonksyone byen.
  • Obsève tout kòd sekirite lokal ak nasyonal yo.
  • Asire w ke ou chwazi fonksyon ak ranje ki kòrèk la anvan ou pran mezi yo.
  • Avoid working alone in hazardous environments.

2.2 Intrinsically Safe Operation

The Fluke 28IIEX/ETL is designed for use in hazardous locations classified as:

  • ATEX: II 2 G Ex ia IIC T4 Gb, II 2 D Ex ia IIIC T130°C Db, I M1 Ex ia I Ma
  • NEC-500: Class I, Div 1, Groups A-D, 130 °C
  • IEXEx: Ex ia IIC T4 Gb, Ex ia IIIC T130°C Db, Ex ia I Ma

These ratings ensure the device will not ignite explosive atmospheres under normal or fault conditions. Always ensure the device is used within its specified environmental and electrical limits for intrinsically safe operation.

2.3 Electrical Safety Ratings

The multimeter meets International Electrotechnical Commission (IEC) safety standard 61010 and is certified for:

  • Category III 1000V: For measurements on building circuit installations (e.g., service panel parts, branch circuits, fixed installations).
  • Category IV 600V: For measurements at the origin of the installation (e.g., electricity meters, primary over-current protection equipment).
  • Degre polisyon 2: Pou itilize andedan kay la.

2.4 Pwoteksyon Anviwònman

The device is Ingress Protection (IP) certified IP67, meaning it is waterproof, dust-proof, and drop-proof, suitable for harsh industrial environments.

3. Pwodwi souview

The Fluke 28IIEX/ETL is a robust digital multimeter designed for reliability and accuracy. It features a large LCD display with a two-level bright white backlight for visibility in various lighting conditions.

Fluke 28IIEX/ETL Intrinsically Safe True-RMS Digital Multimeter

Figi 1: Devan view of the Fluke 28IIEX/ETL Digital Multimeter. The image displays the device with its red protective holster, gray body, LCD screen showing '28.20 V AC', and the rotary dial for function selection. Below the dial are the input jacks for current, voltage, and common connections, along with safety warnings and certifications.

3.1 Karakteristik kle

  • True-RMS measurements for accurate readings on linear and non-linear loads.
  • Auto- and manual-ranging capabilities.
  • Mezi voltage, current, resistance, capacitance, frequency, temperature, conductance, and duty cycle.
  • Performs continuity and diode tests.
  • Low-pass filter for accurate voltage and frequency measurements on variable-speed motor drives.
  • MIN/MAX/AVG and Peak Capture functions to record transients and measurement variations.
  • Relative mode to remove test lead interference.
  • Backlit keypad buttons and display for low-light conditions.
  • Audible alarm for incorrect test lead connection.

4. Enstalasyon

4.1 Enstalasyon batri

The Fluke 28IIEX/ETL requires four (4) AA alkaline batteries for operation. To install or replace batteries:

  1. Asire w ke miltimèt la etenn.
  2. Retire pòch kawotchou pwoteksyon an.
  3. Locate and open the battery compartment cover on the rear of the device.
  4. Insert four new AA alkaline batteries, observing the correct polarity markings.
  5. Securely close the battery compartment cover and reattach the holster.

4.2 Konekte fil tès yo

Always connect test leads to the appropriate input jacks for the measurement being performed. The multimeter will sound an alarm if leads are connected incorrectly for the selected function.

  • COM Jack: Connect the black test lead to the common (COM) jack for all measurements.
  • VΩHz Jack: Connect the red test lead to this jack for voltage, resistance, frequency, capacitance, and diode tests.
  • mAµA Jack: Connect the red test lead to this jack for current measurements up to 400mA. This input is fused.
  • 10A Max Fused Jack: Connect the red test lead to this jack for current measurements up to 10A. This input is fused.

5. Operasyon Enstriksyon

Turn the rotary switch to the desired function. The multimeter defaults to auto-ranging mode, automatically selecting the correct measurement range. Press the 'RANGE' button to switch to manual ranging.

5.1 Mezire Voltage (AC/DC)

  1. Connect the black lead to COM and the red lead to VΩHz.
  2. Turn the rotary switch to V~ (AC Voltage) oubyen V- (Volim DCtagak).
  3. Konekte fil tès yo atravè sikwi a oswa konpozan ki pral mezire a.

5.2 Measuring Current (mA/A/µA)

WARNING: Never attempt to measure current by connecting the multimeter in parallel with a voltage source. This can damage the meter and cause injury.

  1. Connect the black lead to COM. Connect the red lead to mAµA for small currents or 10A Max Fused for larger currents.
  2. Turn the rotary switch to mA/A~ (AC Current) or mA/A- (DC Current).
  3. Louvri sikwi a epi konekte miltimèt la an seri ak chaj la.

5.3 Mezire Rezistans (Ω)

  1. Connect the black lead to COM and the red lead to VΩHz.
  2. Turn the rotary switch to Ω.
  3. Ensure the circuit is de-energized. Connect the test leads across the component.

5.4 Tès kontinwite

  1. Connect the black lead to COM and the red lead to VΩHz.
  2. Turn the rotary switch to the continuity symbol (speaker icon).
  3. Ensure the circuit is de-energized. Connect the test leads across the component. An audible tone indicates continuity.

5.5 Tès Dyòd

  1. Connect the black lead to COM and the red lead to VΩHz.
  2. Turn the rotary switch to the diode symbol.
  3. Ensure the circuit is de-energized. Connect the test leads across the diode. The display shows the forward voltage gout.

5.6 Mezire Kapasitans (F)

  1. Connect the black lead to COM and the red lead to VΩHz.
  2. Turn the rotary switch to the capacitance symbol.
  3. Ensure the capacitor is discharged before connecting the test leads.

5.7 Measuring Frequency (Hz) and Duty Cycle (%)

  1. Connect the black lead to COM and the red lead to VΩHz.
  2. Turn the rotary switch to Hz.
  3. Connect the test leads across the signal source. Press the '%' button to view sik devwa.

5.8 Measuring Temperature (°C/°F)

  1. Connect the K-type thermocouple (included) to the VΩHz and COM jacks, observing polarity.
  2. Turn the rotary switch to the temperature symbol.
  3. Place the thermocouple tip on the object to be measured.

5.9 Fonksyon espesyal

  • MIN MAX: Press to record minimum, maximum, and average readings over time.
  • PEAK MIN MAX: Captures fast transients.
  • REL Δ (Relative Mode): Subtracts the stored reading from subsequent readings, useful for nulling out test lead resistance.
  • RETE: Li bloke lekti aktyèl sou ekran an.

6. Antretyen

6.1 Netwayaj

Siye ka a ak anonsamp cloth and mild detergent. Do not use abrasives or solvents. Ensure the device is dry before use.

6.2 Ranplasman batri

Gade Seksyon 4.1 pou enstriksyon sou ranplasman pil yo. Ranplase pil yo lè endikatè pil ki fèb la parèt sou ekran an.

6.3 Ranplasman Fuse

WARNING: To prevent injury or damage to the multimeter, use only specified replacement fuses with the correct amperage, voltage, ak entèwonp evalyasyon.

The Fluke 28IIEX/ETL has two internal fuses:

  • 10A Max Fused: For the 10A current input.
  • 400mA Fused: For the mA/µA current input.

Fuse replacement should only be performed by qualified personnel. Consult the full service manual or contact Fluke customer support for detailed instructions.

NAN. Depanaj

If the multimeter is not functioning as expected, review pwoblèm komen sa yo:

  • Pa gen ekspozisyon oswa ekspozisyon an fèb: Tcheke pil yo epi ranplase yo si sa nesesè.
  • Lekti ki pa kòrèk: Ensure test leads are correctly connected, the function and range are appropriate for the measurement, and the circuit is de-energized for resistance/continuity/diode tests.
  • Mezi aktyèl la pa fonksyone: Check the fuses for the respective current input (10A or 400mA). Replace if blown.
  • Multimeter does not respond: Turn the unit off and then on again. If the issue persists, remove batteries for a few minutes and reinsert.

For persistent issues or complex problems, contact Fluke customer support.

8. Espesifikasyon

ParamètSpesifikasyon
Maximum AC/DC Current Input10 A
Maximum AC/DC Voltage Antre1000 V
Maximum Resistance Detected50 MΩ
Frekans maksimòm199.99 kHz
Maksimòm kapasite9999µF
Temperature Range (excluding probe)-200 a +1090 °C / -328 a +1994 °F
Ranje Sik Devwa0 a 99.9%
EkspozisyonLCD with 20,000-count resolution, two-level backlight
Pwovizyon pou pouvwa4 pil AA (alkalin)
Evalyasyon Sekirite SosyalATEX, NEC-500, IEXEx, IEC 61010, CAT III 1000V, CAT IV 600V, Pollution Degree 2
Pwoteksyon IngressIP67 (Waterproof, Dust-proof, Drop-proof)
Pwa2.85 liv (1.29 kg)
Dimansyon (L x W x H)9.7 x 6.3 x 3.36 pous (24.6 x 16.0 x 8.5 cm)

9. Garanti ak sipò

Fluke Corporation products are designed for reliability and performance. For warranty information, technical support, or service, please visit the official Fluke website or contact your local Fluke representative.

Official Fluke Websit: www.fluke.com

Dokiman ki gen rapò - 28IIEX/ETL

Preview Miltimèt Fluke 110 True-RMS: Espesifikasyon teknik ak karakteristik
Espesifikasyon detaye ak karakteristik miltimèt kontra enfòmèl ant Fluke 110 True-RMS la, ki fèt pou enstalasyon elektrik presi ak depanaj. Gen ladan presizyon, evalyasyon sekirite, ak akseswa ki enkli.
Preview Miltimèt Fluke 116 True-rms: Gid Referans Rapid
Gid referans rapid pou Fluke 116 True-rms Multimeter la, ki detaye fonksyon li yo, kapasite mezi li yo, ak itilizasyon li pou tès elektrik.
Preview Miltimèt dijital Fluke 179: Gid antretyen ak sèvis sou teren
Dekouvri Miltimèt Dijital Fluke 179 True-rms la, ki fèt pou antretyen elektrik ak HVAC efikas. Aprann plis sou karakteristik li yo, espesifikasyon li yo, ak akseswa rekòmande pou yon sèvis serye sou teren.
Preview Fluke 323/324/325 Clamp Manyèl itilizatè mèt
Manyèl itilizatè konplè pou Fluke 323, 324, ak 325 clamp mèt, detay sou karakteristik yo, prekosyon sekirite, espesifikasyon, ak gid operasyonèl pou mezi elektrik egzat.
Preview Fluke 370 FC Seri Vrè-RMS Entèmedyè San Fil AC/DC Clamp Mèt - Done Teknik
Espesifikasyon teknik detaye, karakteristik, ak enfòmasyon sou kòmand pou Fluke 370 FC Series True-rms Wireless AC/DC Cl la.amp Aparèy mèt yo, ki gen ladan modèl 374 FC, 375 FC, ak 376 FC. Li kouvri kapasite mezi, tablo konparezon, ak sistèm Fluke Connect la.
Preview Fluke 114, 115, 116, 117 Digital Multimeters: User Manual and Specifications
Detailed specifications, features, and user guide for Fluke 114, 115, 116, and 117 True-rms Digital Multimeters, covering safety, operation, maintenance, and technical data.