1. Entwodiksyon
This manual provides essential information for the safe and effective use of the Jard 12739 40/3 MFD 370V Round Motor Run Capacitor. This component is specifically designed for use in Appliances, Motors, HVAC Equipment, Compressors, Office Equipment, and other applications where run capacitors are employed with Permanent Split Capacitor (PSC) type motors and/or compressors.
The capacitor utilizes a specialized film technology, enabling a compact design while maintaining long-life performance and reliability. It is engineered to meet or exceed the reliability standards of previous designs, even with its smaller form factor.

Figi 1.1: Devan view of the Jard 12739 40/3 MFD 370V Round Motor Run Capacitor, showing the label with specifications and model number.
2. Enfòmasyon sou Sekirite
WARNING: Electrical components can store dangerous charges. Always consult a qualified professional for installation and service. Failure to follow these safety guidelines may result in serious injury or death.
- Dekonekte pouvwa: Always ensure that the main power supply to the equipment is disconnected and locked out before attempting any installation, maintenance, or troubleshooting.
- Kondansateur egzeyat: Capacitors can retain a dangerous electrical charge even after power is disconnected. Always discharge the capacitor safely using a properly insulated tool before handling.
- Zouti ki apwopriye yo: Use only insulated tools and personal protective equipment (PPE) suitable for electrical work.
- Enstalasyon pwofesyonèl: Installation and replacement of motor run capacitors should only be performed by trained and qualified technicians.
- Verifye Espesifikasyon yo: Ensure the replacement capacitor matches the original component's specifications (MFD, Voltage) to prevent damage to the motor or equipment.
- Evite kontak: Do not touch the terminals or body of the capacitor while power is connected or before it has been safely discharged.
3. Pwodwi Features
- Konsepsyon kontra enfòmèl ant: Features a new compact design with 0.250" x 0.031" Quick Connect Terminals for easy installation.
- Asirans Kalite: Each capacitor is tested prior to shipping and individually boxed to ensure quality and reliability.
- Industry Standard Compliance: Conforms to EIA-456-A Industry Reliability Standard, meeting 60,000 hours of life performance.
- Konsistans pèfòmans: The physical size of the capacitor does not affect its electrical performance. Dimensions are subject to change without prior notice.
- Gwo konpatibilite: Compatible replacement for various models including Capcom Obsolete GE / Genteq C3403, C3403R, 97F9473, 97F9473BX, Mars SUPCO CD40+3X370R, and other 40/3, 40+3, 40 + 3 Capacitors with matching specifications.

Figi 3.1: Top view of the capacitor showing the three quick-connect terminals for electrical connections.
4. Enstalasyon ak Enstalasyon
Installation of a motor run capacitor requires knowledge of electrical systems and safety procedures. It is strongly recommended that installation be performed by a certified HVAC technician or a qualified electrician.
- Dekoneksyon pouvwa: Turn off and lock out the main power supply to the equipment where the capacitor is to be installed or replaced. Verify power is off using a multimeter.
- Kondansateur Aksè: Locate and access the existing capacitor within the equipment.
- Dechaje Ansyen Kondansateur a: Carefully discharge the old capacitor using a screwdriver with an insulated handle by shorting the terminals. Listen for a pop or spark, indicating discharge. For dual capacitors, discharge each terminal to common.
- Remak Fil elektrik: Before disconnecting, take a clear photograph or draw a diagram of the existing wiring connections to the capacitor terminals. Note which wire goes to "Herm" (compressor), "Fan" (fan motor), and "C" (common).
- Retire ansyen kondansateur a: Disconnect the wires from the old capacitor and remove it from its mounting bracket.
- Enstale nouvo kondansateur a: Secure the new Jard 12739 capacitor in the mounting bracket.
- Konekte fil elektrik: Reconnect the wires to the corresponding terminals on the new capacitor, following the diagram or photograph taken earlier. Ensure connections are secure.
- Verifye enstalasyon: Tcheke tout koneksyon yo de fwa pou wè si yo kòrèk epi an sekirite.
- Retabli pouvwa: Restore power to the equipment and test its operation.


Figi 4.1: Examples of capacitor dimensions. The actual dimensions may vary slightly, but performance remains consistent. Always verify physical fit before installation.
5. Prensip Operasyon yo
A motor run capacitor, such as the Jard 12739, is an essential component in many AC motors, particularly Permanent Split Capacitor (PSC) motors found in HVAC systems, refrigerators, and other appliances. Its primary function is to create a phase shift in the current supplied to the motor's start winding, which generates a rotating magnetic field. This rotating field provides the necessary torque to start the motor and helps maintain its efficiency during operation.
Unlike start capacitors, run capacitors are designed for continuous duty. They remain in the circuit while the motor is running, improving the motor's power factor and overall efficiency by reducing the amount of reactive power drawn from the electrical supply. The 40/3 MFD rating indicates a dual capacitor: 40 microfarads for the compressor (Herm) and 3 microfarads for the fan motor (Fan), with a common (C) terminal.
6. Antretyen
Motor run capacitors are generally sealed units and require minimal maintenance. However, periodic inspection can help identify potential issues before they lead to component failure.
- Enspeksyon vizyèl: During routine equipment maintenance, visually inspect the capacitor for signs of swelling, bulging, leaks, or corrosion around the terminals. These are indicators of a failing capacitor.
- Lapwòpte: Ensure the area around the capacitor is free from dust, dirt, and debris, which can hinder heat dissipation.
- Tanperati: Operate the equipment within its specified temperature range. Excessive heat can shorten the lifespan of the capacitor.
- Tcheke pwofesyonèl: It is advisable to have a qualified technician periodically check the capacitance value using a multimeter with a capacitance function. A deviation of more than 10-20% from the rated MFD value typically indicates a need for replacement.
NAN. Depanaj
A failing motor run capacitor can cause various symptoms in the equipment it serves. If you suspect a capacitor issue, always consult a qualified technician for diagnosis and replacement.
Common Symptoms of a Failing Capacitor:
- Motor Fails to Start: The motor hums but does not start, or starts slowly and then stops.
- Efikasite redwi: The motor runs but draws excessive current, leading to higher energy consumption or overheating.
- Weak Airflow (HVAC): In air conditioning units, a weak fan motor capacitor can lead to reduced airflow from the outdoor unit.
- Audible Clicks/Buzzes: Unusual noises coming from the motor or capacitor area.
- Domaj Fizik: Visible signs of damage on the capacitor itself, such as bulging, leaking fluid, or a burnt smell.
Nòt: Do not attempt to test or replace a capacitor without proper training and safety precautions. Capacitors can store lethal electrical charges.
8. Espesifikasyon
| Atribi | Valè |
|---|---|
| Mak | Mas |
| Nimewo Modèl | 12739 |
| Kapasite | 40/3 MFD (Microfarads) |
| Opere Voltage | X N ACT Volts AC |
| Maksimòm Voltage | X N ACT Volts AC |
| Fòm | Round |
| Materyèl | Copper (Terminals/Internal Wiring) |
| Tèminal yo | 0.250" x 0.031" Quick Connect |
| Creole endistri | EIA-456-A (60,000 hours life) |
| Dimansyon pake | Approx. 6 x 3 x 3 inches (Product dimensions may vary) |
| Pwa | Apeprè. 12 ons |
| Premye Dat ki disponib | 25 janvye 2012 |
| Manifakti | MAS |
9. Garanti ak sipò
Specific warranty terms for the Jard 12739 40/3 MFD 370V Round Motor Run Capacitor are typically provided by the manufacturer (Mars) or the authorized seller at the time of purchase. Please refer to your purchase documentation or contact the seller directly for detailed warranty information.
For technical support, installation guidance, or troubleshooting assistance, it is recommended to contact a qualified HVAC technician or the manufacturer's customer service department. Always ensure that any service or repair is performed by a certified professional to maintain safety and product integrity.

Figi 9.1: A quality assurance stamp, indicating adherence to component standards.