1. Entwodiksyon
This manual provides comprehensive instructions for the safe and effective operation of the Extech MS6100 2-Channel Digital Oscilloscope. The MS6100 is a versatile instrument designed for precise electrical testing and measurement, combining the functionalities of a digital oscilloscope and a TRMS multimeter.
Key features include a 5.6-inch color LCD, high sampling rate, extensive record length, and various measurement capabilities. Please read this manual thoroughly before using the device to ensure proper handling and to maximize its performance.
2. Enfòmasyon sou Sekirite
WARNING: To avoid electric shock or personal injury, read the safety information carefully before using the product.
- Always use the instrument with the specified probes and accessories.
- Do not use the instrument if it appears damaged or if it is not operating properly.
- Obsève tout kòd sekirite lokal ak nasyonal yo.
- Ensure the power adapter is correctly rated for your local power supply.
- Pa ekspoze enstriman an ak lapli oswa imidite.
- Refere tout sèvis yo bay pèsonèl sèvis kalifye.
3. Pwodwi souview
The Extech MS6100 integrates a powerful 2-channel digital oscilloscope with a full-featured TRMS multimeter, offering a compact and robust solution for field and bench measurements.
3.1 Karakteristik prensipal yo
- 100MHz Bandwidth for precise signal analysis.
- 5.6" (142mm) color LCD display for clear waveform visualization.
- 500MS/s sampling rate per channel for detailed signal capture.
- 1M point record length per channel for extended waveform recording.
- Built-in TRMS MultiMeter with 6000 count display and analog bargraph.
- One-touch automatic setup for optimized display.
- 23 Automatic Measurements.
- Waveform Math functions (Add, Subtract, Multiply, Divide).
- Automatic cursor tracking measurements.
- XY Mode for phase relationship analysis.
- Built-in FFT function for frequency domain analysis.
- Storage and recall of up to 1000 waveform screens and setups on 2G microSD card.
- Waveform Recorder for capturing/replaying input waveforms.
3.2 Instrument Layout

Figi 3.1: Devan view of the Extech MS6100 Digital Oscilloscope, showing the color LCD display, function buttons (F1-F5), navigation controls, input terminals (10A, FUSED/MAX 0.6A, mA, COM, V/Ω/C, CAT II 600V), and dedicated buttons for oscilloscope and multimeter functions.
The front panel features a large color LCD for displaying waveforms and measurement data. Below the screen are five function buttons (F1-F5) whose labels change dynamically on the screen. The main control area includes dedicated buttons for voltage (V), current (A), resistance (Ω), diode test, continuity, save/recall, utility, cursor, measure, and menu navigation. Input terminals for oscilloscope channels (CH1, CH2) and multimeter functions are located at the bottom, along with the power button and auto-setup button.
4. Enstalasyon ak Premye Operasyon
4.1 Debalaj ak enspeksyon
Carefully unpack the instrument and verify that all items are present and undamaged. The package should include:
- Extech MS6100 Digital Oscilloscope
- Two 1X/10X oscilloscope probes
- Test leads for multimeter functions
- Windows® compatible software and USB cable
- Universal AC adaptor/charger
- Ka pote
- MicroSD card (2G, installed)
4.2 Enstalasyon ak Chaje Batri
The MS6100 is powered by one Lithium Ion battery (included and pre-installed). Ensure the battery is fully charged before first use. Connect the universal AC adaptor/charger to the instrument's charging port and to a suitable AC power outlet. The charging indicator will show the charging status.
4.3 Limen/Etenyen
Pou limen aparèy la, peze epi kenbe bouton an Pouvwa button (orange circle with power symbol) located at the bottom left of the control panel. To power off, press and hold the same button until the display shuts down.
4.4 Inisyal Enstalasyon
Upon first power-on, the device may prompt for language selection or other initial settings. Use the navigation buttons and F-buttons to configure as needed. The built-in multi-language help system can be accessed via the pop-up menu.
5. Operasyon Enstriksyon
5.1 Mòd Osiloskop
To enter Oscilloscope mode, press the OSC DMM button. The display will show the waveform grid and channel information.
- Connecting Probes: Connect the oscilloscope probes to the CH1 and CH2 BNC inputs. Ensure the probe attenuation setting (1X/10X) matches the setting on the oscilloscope.
- Enstalasyon oto: For quick waveform display, press the OTO button (bottom right). This optimizes position, range, timebase, and triggering.
- Vertical Controls (VOLTS): Sèvi ak la VOLLT buttons for CH1 and CH2 to adjust the vertical scale (Volts/Div). Use the associated up/down arrows to adjust vertical position.
- Horizontal Controls (TIME/DIV): Sèvi ak la TAN/DIV buttons to adjust the horizontal scale (Time/Div). Use the associated left/right arrows to adjust horizontal position.
- Deklanche: Sèvi ak la DEklanche button and associated controls to set the trigger level and mode for stable waveform capture.
- Mezi: Peze a MEZI button to access automatic measurements (e.g., frequency, peak-to-peak voltagak).
- Kurseur: Peze a KURSÈ button to enable and position horizontal and vertical cursors for manual measurements.
- Waveform Math: Access Add, Subtract, Multiply, and Divide functions via the MENI ON/OFF button and navigating to the Math menu.
- Fonksyon FFT: Convert time-domain signals to frequency components using the FFT function, accessible through the menu.
- Mòd XY: For displaying phase relationships between two signals, select XY Mode from the menu.
5.2 Mòd Miltimèt
To switch to Multimeter mode, press the OSC DMM button again. The display will show multimeter readings.
- Konekte fil tès yo: Connect the red test lead to the V/Ω/C or mA terminal and the black test lead to the COM terminal. For high current measurements, use the 10A terminal.
- Seleksyon Fonksyon: Use the dedicated buttons (V, A, Ω, Diode, Continuity) to select the desired measurement function.
- Ekspozisyon lekti: The 6000 count display will show the measurement value, and an analog bargraph provides a visual indication of the reading.
5.3 Depo ak Rapèl Done
The MS6100 allows for extensive data storage on its internal 2G microSD card.
- Saving Waveforms/Setups: Peze a SAVE RECALL button, then follow the on-screen prompts to save current waveform screens or instrument setups. Up to 1000 items can be stored.
- Rapèl Done: Peze a SAVE RECALL button and navigate to the recall option to view previously saved waveforms or load setups.
- Waveform Recorder: The Waveform Recorder function allows capturing and replaying input waveforms from CH1 and CH2 with a maximum record length of 1000 frames. Access this feature through the Utility menu.
6. Antretyen
6.1 Netwayaj
Regular cleaning helps maintain the instrument's performance and appearance.
- Siye ka a ak anonsamp twal ak detèjan twò grav. Pa sèvi ak abrazif oswa solvang.
- Ensure no liquid enters the instrument.
- Clean the display screen gently with a soft, lint-free cloth.
6.2 Swen Batri
Pou pwolonje lavi batri:
- Recharge the battery regularly, even if the instrument is not in frequent use.
- Evite estoke enstriman an nan tanperati ekstrèm.
- If the instrument will not be used for an extended period, charge the battery to approximately 50% before storage.
6.3 Depo
When not in use, store the MS6100 in its carrying case in a cool, dry place, away from direct sunlight and extreme temperatures.
NAN. Depanaj
Seksyon sa a bay solisyon pou pwoblèm komen ou ka rankontre. Si pwoblèm nan pèsiste, kontakte sèvis kliyan.
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Enstriman an pa limen. | Battery is depleted or not properly installed. Power adapter not connected or faulty. | Charge the battery using the AC adapter. Ensure the battery is correctly seated. Check AC adapter connection. |
| No waveform displayed in Oscilloscope mode. | Probe not connected, signal too small/large, incorrect time/div or volts/div settings, trigger not set correctly. | Ensure probes are connected to the correct inputs and the signal source. Press OTO. Adjust VOLTS/DIV and TIME/DIV. Adjust trigger level. |
| Multimeter readings are inaccurate. | Incorrect function selected, test leads not properly connected, faulty test leads. | Verify the correct measurement function is selected. Ensure test leads are securely connected to the appropriate terminals. Try different test leads if available. |
| Cannot save data to microSD card. | MicroSD card full, card error, or card not properly inserted. | Check available space on the microSD card. Reinsert the card. Format the card (this will erase all data). |
8. Espesifikasyon
Detailed technical specifications for the Extech MS6100 Digital Oscilloscope.
| Paramèt | Valè |
|---|---|
| Manifakti | Sistèm FLIR |
| Nimewo Pati | MS6100 |
| Pwa atik | 5.5 liv |
| Dimansyon pwodwi | 9.6 x 6.4 x 2 pous |
| Nimewo Modèl Atik | MS6100 |
| Batri | 1 pil ityòm Ion obligatwa (enkli) |
| Style | 100 MHz |
| Kantite pake atik | 1 |
| Dat Premye Disponib | 6 out 2012 |
| Bandwidth | 100MHz |
| Ekspozisyon | 5.6" (142mm) color LCD |
| Sampling To | 500MS/s per channel |
| Longè dosye | 1M point per channel |
| Multimeter Display | 6000 count with analog bargraph |
9. Garanti ak sipò
9.1 Enfòmasyon sou Garanti
Extech instruments are warranted to be free from defects in parts and workmanship for a specified period from the date of shipment (typically one year). For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Extech website. This warranty does not cover damage from abuse, accident, neglect, alteration, contamination, or abnormal conditions of operation or handling.
9.2 Sipò teknik
For technical assistance, troubleshooting, or service inquiries, please contact Extech customer support. Before contacting support, please have your product model number (MS6100) and a detailed description of the issue ready. You can find contact information on the official Extech websit oswa nan dokiman yo bay ak acha w la.