1. Entwodiksyon

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Vortice Record Extractor Fan M10/4T 100mm with Timer. This unit is designed for intermittent or continuous ventilation in small to medium domestic or commercial premises, such as bathrooms, utility rooms, or kitchens. Please read these instructions thoroughly before installation and use, and retain them for future reference.

Vortice Record Extractor Fan M10/4T 100mm with Timer

Figi 1: Devan view of the Vortice Record Extractor Fan M10/4T 100mm with Timer. This image displays the fan's white casing and central circular grille.

2. Enfòmasyon sou Sekirite

AVÈTISMAN: Pou diminye risk pou dife, chòk elektrik, oswa blesi sou moun, obsève bagay sa yo:

  • Installation must be carried out by a qualified electrician in accordance with all local and national wiring regulations.
  • Toujou dekonekte ekipman pou kouran an anvan ou fè nenpòt enstalasyon, antretyen oswa netwayaj.
  • Aparèy sa a pa fèt pou itilize pa moun (ki gen ladan timoun) ki gen kapasite fizik, sansoryèl oswa mantal redwi, oswa ki pa gen eksperyans ak konesans, sof si yo te ba yo sipèvizyon oswa enstriksyon konsènan itilizasyon aparèy la pa yon moun ki responsab sekirite yo.
  • Timoun yo ta dwe sipèvize pou asire ke yo pa jwe ak aparèy la.
  • Pa sèvi ak fanatik sa a avèk nenpòt aparèy kontwòl vitès solid.
  • Ensure that the air discharge is not obstructed.
  • The fan must not be installed in areas where the ambient temperature exceeds 40°C (104°F).

3. Pake kontni

Carefully unpack the product and check for any damage. If any components are missing or damaged, contact your retailer immediately.

  • Vortice Record Extractor Fan M10/4T unit
  • Manyèl Enstriksyon
  • Materyèl pou monte (vis, ploge miray)
  • Power cord (may not be included depending on regional regulations or specific model variant)

4. Espesifikasyon

The following table outlines the key technical specifications for the Vortice Record Extractor Fan M10/4T 100mm with Timer.

KarakteristikSpesifikasyon
MakToubiyon
Non modèlM10/4T (11630)
Konsepsyon fanatik elektrikFanatik echapman
Sous pouvwaKab elektrik
Voltage240 Volts
Wattage16 Watts
Kapasite Flow Air85 Cubic Meters Per Hour (approx. 50 CFM)
Nivo bri39 Desibèl
Longè lam100 Milimèt
Pwa atik0.43 Kilogram (apeprè 15.1 ons)
Dimansyon pake18.4 L x 7.6 H x 13.0 W (centimeters) / 7.6 x 5.39 x 3.23 (inches)
Kalite enstalasyonMi mòn
Kalite chanmTwalèt
Karakteristik espesyalFonksyon revèy
Metòd kontwòlTouch (likely referring to external switch)
Fini KaliteMetalik
SètifikasyonCE Apwouve
Vortice Record Extractor Fan M10/4T Energy Label

Figi 2: Technical data and energy label for the Vortice Record Extractor Fan. Key data points include a maximum flow rate of 82 m³/h, total electrical power consumption of 14.3 W at maximum flow, and a sound power level (LWA) of 51 dB(A).

5. Enstalasyon

Installation should only be performed by a qualified professional to ensure compliance with electrical safety standards and optimal performance.

5.1. Chwazi yon Kote

Select a suitable wall-mount location, typically in a bathroom or utility area, ensuring adequate space for the fan and ducting. Avoid locations directly above heat sources or where the fan might be exposed to direct water spray.

Vortice Extractor Fan installed in a kitchen

Figi 3: Example of a Vortice extractor fan installed on a wall in a room, demonstrating typical placement for ventilation.

5.2. aliye ak câblage

  1. Prepare Ouvèti a: Create an appropriate opening in the wall for the fan's ducting, typically 100mm in diameter. Refer to the dimensional drawing for precise measurements.
  2. Fikse vantilatè a: Mount the fan unit securely to the wall using the provided mounting hardware. Ensure it is level and stable.
  3. Koneksyon elektrik: Connect the fan to the main electrical supply. The M10/4T model includes a timer function, which requires specific wiring to a switched live and permanent live supply. Consult the wiring diagram provided with the product packaging or a qualified electrician for correct connection.
  4. Kanal: Connect appropriate ducting to the fan's outlet to direct extracted air outdoors. Ensure all connections are sealed to prevent air leakage.
Vortice Extractor Fan Dimensional Drawing

Figi 4: Technical drawing illustrating the dimensions of the Vortice Extractor Fan, including overall width (A), height (B), depth (C), and duct diameter (E, F).

6. Operasyon

The Vortice Record Extractor Fan M10/4T is designed for simple operation, typically controlled via an external light switch or a dedicated fan switch.

6.1. Basic On/Off

When connected to a light switch, the fan will activate when the light is turned on. When connected to a dedicated fan switch, simply toggle the switch to turn the fan on or off.

6.2. Fonksyon revèy

The M10/4T model features an adjustable timer. After the fan is switched off (e.g., by turning off the light), the fan will continue to operate for a preset duration before automatically shutting down. This duration can typically be adjusted using a small potentiometer located within the fan unit (access usually requires removing the front cover and disconnecting power). Experiment with the timer setting to achieve the desired run-on time for effective ventilation.

7. Antretyen

Regular maintenance ensures optimal performance and longevity of your extractor fan. Always disconnect the power supply before any maintenance.

7.1. Netwaye Eksteryè a

Siye deyò vantilatè a ak yon twal mou.amp twal. Pa sèvi ak pwodui netwayaj abrazif, solvan, oswa pwodui chimik ki agresif, paske sa yo ka domaje fini an.

7.2. Cleaning the Fan Blades

Periodically, dust and debris may accumulate on the fan blades, reducing efficiency. To clean:

  1. Dekonekte pouvwa: Ensure the fan's power supply is completely disconnected at the circuit breaker.
  2. Retire kouvèti: Carefully remove the front grille or cover of the fan.
  3. Netwaye lam: Gently clean the fan blades and surrounding areas with a soft brush or a vacuum cleaner with a brush attachment. Avoid bending the blades.
  4. Remonte: Once clean, reattach the cover securely.
Vortice Extractor Fan Internal View

Figi 5: Entèn view of the Vortice Extractor Fan, showing the fan blades and motor housing, which may require periodic cleaning.

NAN. Depanaj

If you encounter issues with your Vortice Extractor Fan, refer to the following common problems and solutions:

PwoblèmKòz posibSolisyon
Fanatik pa limenPa gen ekipman pou pouvwa
Fil elektrik defo
Fòt entèn
Check circuit breaker and wall switch. Ensure correct wiring (consult electrician). If problem persists, contact support.
Vantilatè a fè twòp briMontaj ki lach
Obstruction nan lam fanatik yo
Pwoblèm motè
Ensure fan is securely mounted. Disconnect power and check for obstructions. If noise persists, contact support.
Ensifizan ekstraksyon lèBlocked ducting
Lam fanatik sal
Incorrect fan size for room
Check ducting for blockages. Clean fan blades as per maintenance section. Ensure fan is appropriately sized for the room volume.
Timer not working correctlyMove anviwònman revèy
Pwoblèm fil elektrik
Adjust the timer potentiometer. Verify timer wiring with an electrician.

For issues not listed here or if solutions do not resolve the problem, please contact qualified technical support.

9. Garanti ak sipò

9.1. Enfòmasyon sou Garanti

Please refer to the warranty card or documentation included with your purchase for specific warranty terms and conditions. Keep your proof of purchase for any warranty claims.

9.2. Sipò pou Kliyan

For technical assistance, spare parts, or service, please contact your retailer or visit the official Vortice websit pou enfòmasyon kontak sipò.

Dokiman ki gen rapò - M10/4T

Preview Vortice Quadro Medio - Manuale di Istruzioni
Manuale completo per l'installazione, l'uso e la manutenzione del ventilatore Vortice Quadro Medio. Include dettagli sui modelli, collegamenti elettrici, impostazioni del timer e avvertenze di sicurezza.
Preview Manual di Instruzioni Vortice Punto: Modelli M 90, M 100, M 120, M 150
Manuale completo per l'installation, l'uso e la maintenance degli aspiratori Vortice Punto, con dettagli sui model M 90, M 100, M 120, M 150 e M 100 12V. Mete avvertenze di sicurezza e specifiche tecniche.
Preview Vortice VORT QUADRO MEDIO - Manuale di Istruzioni
Manuale di istruzioni completo per l'aspiratore centrifugo Vortice VORT QUADRO MEDIO, che include dettagli su installazione, funzionamento, modelli, manutenzione e avvertenze di sicurezza.
Preview Punto Vortice - Manuale di Instruzioni e Modelli
Manuale di istruzioni per l'aspiratore elicoidale Punto Vortice, enkli dettagli sui model M 90, M 100, M 120, M 150 e M 100 12V. Gen enfòmasyon sou enstalasyon, antretyen ak sekirite.
Preview Vort Max ES Centrifugal Aspirator: Installation and User Manual
Comprehensive instruction manual for the Vortice Vort Max ES wall-mounted centrifugal aspirator, covering product description, compliance, safety warnings, installation, maintenance, wiring diagrams, and disposal.
Preview Vortice VORT QUADRO SUPER: Manuale di Istruzioni e Guida Utente
Guida completa all'installazione, uso e manutenzione del ventilatore centrifugo Vortice VORT QUADRO SUPER. Scopri le funzionalità, le avvertenze di sicurezza e le procedure per garantire prestazioni ottimali e lunga durata.