DSC PC1832

DSC TYCO Alarm System PC1832 with PK5501 Keypad User Manual

Model: PC1832 | Keypad: PK5501 | Version: 4.6

1. Entwodiksyon

This manual provides essential instructions for the installation, operation, and maintenance of your DSC TYCO Alarm System PC1832 with PK5501 Keypad. This system is designed to provide reliable security for your property. Please read this manual thoroughly before attempting any installation or operation to ensure proper functionality and safety.

2. Enfòmasyon sou Sekirite

3. Konpozan enkli

Your DSC TYCO Alarm System kit includes the following components:

Image showing all components of the DSC TYCO Alarm System PC1832 kit, including the control panel, PK5501 keypad, PIR motion detector, 12V battery, transformer, siren, and phone jack.

This image displays the complete kit for the DSC TYCO Alarm System PC1832. Visible components include the main control panel in a metal box, the PK5501 keypad with a digital display, a DSC LC-100-PI PIR motion detector, a 12V battery, a PTC1640U transformer, a DSC siren, and a phone jack.

4. Enstalasyon

The DSC PC1832 alarm system requires careful installation. It supports 8 hardwired zones and is expandable up to 32 zones using PC5108 zone expanders or up to 32 wireless zones.

4.1 Enstalasyon Panèl Kontwòl

  1. Montaj: Securely mount the metal control panel box in a discreet, central location, away from moisture and extreme temperatures.
  2. Fil elektrik: Connect all hardwired zones (e.g., door/window contacts, motion detectors) to the appropriate terminals on the PC1832 panel. Refer to the detailed wiring diagrams in the installer manual for specific connections.
  3. Koneksyon pouvwa: Connect the PTC1640U transformer to the panel's AC terminals. Connect the 12V battery to the battery terminals, ensuring correct polarity. The battery provides backup power during outages.
  4. Koneksyon Sirèn: Connect the DSC siren to the designated siren output terminals.
  5. Phone Line Connection: If using a landline for monitoring, connect the phone jack to the panel's communication terminals.

4.2 Keypad (PK5501) Installation

4.3 Sensor Installation (LC-100-PI PIR)

4.4 Pwogramasyon Inisyal

After physical installation, the system requires programming. This typically involves defining zones, setting user codes, and configuring communication options. The default installer code is often 5555. To enter programming mode, press * lè sa a 8, followed by the installer code.

5. Operasyon Enstriksyon

5.1 Ame Sistèm nan

5.2 Dezame Sistèm nan

5.3 Kontoune Zòn yo

To temporarily bypass a specific zone (e.g., a window left open), press * lè sa a 1, enter the 2-digit zone number, and then your user code. The keypad will confirm the bypass. Bypassed zones are automatically unbypassed when the system is disarmed.

5.4 Chanje Kòd Itilizatè yo

To change a user code, press * lè sa a 5, enter your Master Code, then the 2-digit user number (01-32), and finally the new 4-digit or 6-digit code.

6. Antretyen

6.1 Ranplasman batri

The 12V system battery should be replaced approximately every 3-5 years, or when a 'Low Battery' trouble condition is indicated on the keypad. Disconnect AC power before replacing the battery. Ensure the replacement battery is of the same type and rating.

6.2 Netwayaj Capteur

Periodically clean the lens of the LC-100-PI PIR motion detector with a soft, dry cloth to ensure optimal performance and prevent false alarms caused by dust or debris.

6.3 Tès Sistèm

It is recommended to test your alarm system monthly. To perform a system test, refer to your installer manual or contact your alarm monitoring company for specific instructions. This typically involves arming the system and triggering each zone to ensure proper reporting.

NAN. Depanaj

This section addresses common issues you might encounter with your DSC TYCO Alarm System.

For complex issues or programming difficulties, consult the full DSC PC1832 Installer Manual or contact a professional alarm technician.

8. Espesifikasyon

MakDSC
Nimewo ModèlESM-ALAKIT-96 (PC1832 System)
Koneksyon TeknolojiWired, Wireless (expandable)
Sous pouvwaBattery Powered (with AC transformer)
Voltage12 Volts
Konpozisyon selil batriAsid plon
Konpozan ki enkliPC1832 Panel, PK5501 Keypad, LC-100-PI PIR, Siren, Transformer, 12V Battery, Phone Jack
Aparèy konpatibDoor/Window Contactor, Motion Detector Sensors, Glass Break Sensors, Carbon Monoxide Detectors, Smoke Detectors, Heat Detectors, Low/High Temperature Sensors

9. Garanti ak sipò

For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact your authorized DSC dealer or the seller directly. Keep your proof of purchase for warranty claims.

Dokiman ki gen rapò - PC1832

Preview PowerSeries PC1616/PC1832/PC1864 User Manual
This user manual provides comprehensive instructions for the DSC PowerSeries PC1616, PC1832, and PC1864 security systems, covering installation, operation, programming, troubleshooting, and safety guidelines. It details keypad functions, arming/disarming procedures, alarm types, zone management, and system maintenance.
Preview Manyèl Itilizatè DSC PowerSeries PC1616/PC1832/PC1864
Manyèl itilizatè konplè pou sistèm alam DSC PowerSeries, ki kouvri enstalasyon, operasyon, karakteristik ak depanaj pou modèl PC1616, PC1832 ak PC1864.
Preview DSC PowerSeries Neo HS2LED/HS2ICON/HS2LCD Installation Instructions
This document provides installation instructions for DSC PowerSeries Neo HS2LED, HS2ICON(P)(RF)X, and HS2LCD(P)(RF)X keypads, detailing mounting, wiring, programming, and wireless device configuration.
Preview HS2TCHP E Touchscreen User Manual - DSC Security
User manual for the DSC HS2TCHP E Touchscreen, providing instructions and information on its features, operation, and safety for PowerSeries Neo and Pro alarm systems.
Preview Gid Fil elektrik DSC PC1832: Enstalasyon Kominikatè Selilè Trikdis GT+
Gid konplè pou konekte ak pwograme Kominikatè Selilè Trikdis GT+ la ak panèl kontwòl sekirite DSC PC1832 la, ki gen ladan endikatè estati LED ak enstriksyon konfigirasyon aplikasyon Protegus la.
Preview Manyèl Enstalasyon Kominikatè Alam DSC 3G2060, TL2603G, TL260
Manyèl enstalasyon konplè pou kominikatè alam Kontwòl Sekirite Dijital (DSC), ki detaye konfigirasyon ak konfigirasyon pou modèl 3G2060 (HSPA Selilè), TL2603G (Entènèt doub chemen/HSPA), ak TL260 (Entènèt). Li kouvri enstalasyon, pwogramasyon, sekirite, ak depanaj pou enstalatè sistèm sekirite yo.