1. Entwodiksyon
This user manual provides comprehensive instructions for the installation, operation, and maintenance of your Danfoss RET electronic thermostat. Designed for 230V fan coil units, this thermostat offers precise temperature control with hot/cold switching capabilities.
Please read this manual carefully before installation and use to ensure safe and efficient operation of the device.
2. Pwodwi souview

Figure 2.1: Danfoss RET Electronic Thermostat
This image displays the front of the Danfoss RET electronic thermostat. It features a prominent central rotary dial for setting the desired temperature, marked with numerical values (e.g., 10, 20, 30) and small dots indicating intermediate settings. To the left of the dial, there are symbols for heating (snowflake/star), off (circle), and fan speed (three wavy lines). To the right, there are symbols for fan speed control (three fan icons with horizontal lines). The Danfoss logo is visible at the bottom center. The thermostat is white with grey markings.
Karakteristik kle:
- Designed for 3-speed fan coil units.
- Powered output for 230V speed control and electrothermal head.
- Integrated Hot / Off / Cold switch for mode selection.
- Model Type: RET230CO3.
- Power Supply: 230V AC Mains.
3. Espesifikasyon teknik
| Karakteristik | Spesifikasyon |
|---|---|
| Mak | Danfoss |
| Nimewo Modèl | 087N7032 (RET230CO3) |
| Voltage | 230 Volts |
| Ekleraj | Wi |
| ASIN | B007C1SAA2 |
| Kòd Atik Entènasyonal (EAN) | 05013567873272 |
4. Enstalasyon ak Enstalasyon
Enpòtan: Installation must be carried out by a qualified electrician and in accordance with all local electrical codes and regulations. Ensure the main power supply is disconnected before commencing any installation work.
4.1 Kote montaj
- Mount the thermostat on an interior wall, approximately 1.5 meters (5 feet) above the floor.
- Evite kote ki toupre sous chalè (pa egzanp, limyè solèy dirèk, limyèamps, aparèy) oswa kouran lè (pa egzanp, fenèt, pòt, ouvèti lè) ki ta ka afekte lekti tanperati yo.
- Ensure adequate air circulation around the thermostat.
4.2 Enstriksyon fil elektrik
Refer to the wiring diagram provided with the product packaging for specific connections. General wiring steps include:
- Disconnect power to the fan coil unit circuit at the main breaker.
- Remove the front cover of the thermostat.
- Connect the 230V AC mains supply to the designated terminals (L and N).
- Connect the fan speed control wires (typically Low, Medium, High) and the electrothermal head control wire to their respective terminals as per the diagram.
- Secure all wiring connections firmly.
- Remete kouvèti devan an.
- Retabli pouvwa nan kous la.
5. Operasyon
5.1 Mode Selection (Hot / Off / Cold Switch)
The thermostat features a three-position switch on the side or front for selecting the operating mode:
- Hot (Heating Mode): Select this position for heating. The thermostat will activate the heating function when the room temperature falls below the setpoint.
- Off: Select this position to turn off both heating and cooling functions. The fan may still operate depending on the fan speed setting.
- Cold (Cooling Mode): Select this position for cooling. The thermostat will activate the cooling function when the room temperature rises above the setpoint.
5.2 Ajisteman Tanperati
Adjust the desired room temperature using the large central rotary dial. Rotate the dial clockwise to increase the setpoint temperature and counter-clockwise to decrease it. The numbers on the dial indicate temperature in degrees Celsius.
5.3 Kontwòl vitès fanatik
The thermostat allows control of the fan coil unit's fan speed. Use the fan speed selector (usually a switch or buttons) to choose between:
- Vitès ki ba
- Vitès Mwayen
- Gwo vitès
- Auto (if available): The thermostat automatically adjusts fan speed based on the temperature difference.
6. Antretyen
The Danfoss RET thermostat requires minimal maintenance. Regular cleaning can help ensure optimal performance.
6.1 Netwayaj
- Before cleaning, ensure the power supply to the thermostat is disconnected.
- Siye deyò tèmosta a ak yon twal mou.amp twal.
- Do not use abrasive cleaners, solvents, or chemical sprays, as these can damage the surface or internal components.
- Ensure no moisture enters the thermostat's internal components.
6.2 Sensor Care
Keep the thermostat's vents and openings clear of dust and debris to ensure accurate temperature sensing. Do not obstruct the airflow around the unit.
NAN. Depanaj
If you experience issues with your Danfoss RET thermostat, refer to the following common problems and solutions:
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Tèmosta a pa limen. | No power supply; loose wiring; tripped circuit breaker. | Check circuit breaker. Ensure wiring is secure. Consult a qualified electrician if issues persist. |
| Heating/Cooling not activating. | Incorrect mode selected (Hot/Off/Cold); temperature setpoint not met; fan coil unit issue. | Verify mode switch position. Adjust setpoint. Check fan coil unit's power and operation. |
| Lekti tanperati ki pa kòrèk. | Thermostat located near heat source/draft; obstructed sensor. | Relocate thermostat if possible. Clear any obstructions around the unit. |
| Vantilatè a pa ap fonksyone nan vitès ou chwazi a. | Incorrect fan speed setting; fan coil unit fan motor issue. | Ensure correct fan speed is selected. Consult fan coil unit manual or technician. |
If the problem persists after attempting these solutions, please contact Danfoss customer support or a qualified service technician.
8. Garanti ak sipò
Specific warranty information for the Danfoss RET230CO3 thermostat is typically provided with the product packaging or can be found on the official Danfoss websit la. Tanpri konsève prèv acha ou a pou reklamasyon garanti.
For technical support, spare parts, or service inquiries, please visit the official Danfoss website or contact their customer service department. Contact details can usually be found on the product packaging or the Danfoss websit.