Pwodwi souview
This manual provides detailed instructions for the installation, operation, and maintenance of the Rheem PROTECH SP20075 Pilot Assembly, designed for select natural gas water heaters. This kit is an essential component for ensuring the safe and reliable operation of your water heater.

Image: Rheem PROTECH SP20075 Pilot Assembly kit components.
The Rheem PROTECH SP20075 Pilot Assembly kit includes:
- Pilòt Asanble
- Burner Pòt Joint
- Vis
- Tinnerman Clips
- Enstriksyon enstalasyon (dokiman sa a)
PROTECH is Rheem's OEM (Original Equipment Manufacturer) brand, ensuring that these are factory-authorized parts designed for perfect compatibility and performance with Rheem natural gas water heaters.
Enfòmasyon sou Sekirite
AVÈTISMAN: Installation and service of this pilot assembly must be performed by a qualified installer or service agency. Failure to follow these instructions could result in fire or explosion, causing property damage, personal injury, or death. Always turn off the gas supply and disconnect electrical power to the water heater before beginning any service.
- Ensure adequate ventilation during installation and operation.
- Check all gas connections for leaks using a non-corrosive leak detection solution after installation.
- Pa sèvi ak yon flanm dife ouvè pou tcheke si gen fwit gaz.
- Kenbe materyèl ki ka pran dife lwen aparèy chofaj dlo a.
Enstalasyon ak Enstalasyon
This section outlines the general steps for replacing a pilot assembly. Refer to your specific water heater's manual for detailed diagrams and safety procedures.
- Turn Off Utilities: Shut off the gas supply to the water heater at the main gas valve and turn off the electrical power at the circuit breaker.
- Access the Burner Assembly: Remove the outer access panel and the inner burner door to expose the burner and pilot assembly.
- Disconnect Old Pilot Assembly: Carefully disconnect the thermocouple, pilot tube, and igniter wire from the gas control valve and the burner assembly. Note their positions for reinstallation.
- Retire ansyen jwenti a: Remove the old burner door gasket. Clean the mating surfaces thoroughly.
- Install New Pilot Assembly: Position the new pilot assembly into the burner. Secure it using the provided screws and Tinnerman clips.
- Konekte Konpozan yo: Reconnect the thermocouple, pilot tube, and igniter wire to the gas control valve, ensuring all connections are tight and secure.
- Enstale nouvo jwenti a: Place the new burner door gasket onto the burner door. The gasket may have magnetic properties to hold it in place during installation.
- Remonte: Reinstall the burner door and outer access panel.
- Tcheke pou fwit: Turn on the gas supply. Apply a non-corrosive leak detection solution to all gas connections. Bubbles indicate a leak. If a leak is detected, turn off the gas immediately and tighten the connection or replace the faulty part.
- Retabli pouvwa: Turn on the electrical power to the water heater.
Videyo: Pwodwi finiview of the Rheem PROTECH SP20075 Pilot Assembly. This video provides a visual introduction to the components and their general appearance.
Enstriksyon Operasyon
After successful installation and leak checks, follow these steps to light the pilot and operate your water heater.
- Mete tèmosta a: Turn the water heater thermostat to the lowest setting or "Pilot" if available.
- Light Pilot: Follow the specific pilot lighting instructions located on your water heater's gas control valve. This typically involves pressing and holding the pilot button while simultaneously pressing the igniter button until the pilot flame is established.
- Verify Pilot Flame: Once the pilot is lit, continue holding the pilot button for approximately 30-60 seconds to allow the thermocouple to heat up and hold the pilot flame. Release the button and ensure the pilot remains lit.
- Mete Tanperati: Once the pilot is stable, set the water heater thermostat to your desired temperature. The main burner should ignite shortly after.
If the pilot does not light or stay lit, refer to the Troubleshooting section.
Antretyen
Regular maintenance helps ensure the longevity and efficient operation of your pilot assembly and water heater.
- Enspeksyon anyèl: Have a qualified technician inspect the pilot assembly and burner annually for signs of wear, corrosion, or blockage.
- Clean Pilot Opening: If the pilot flame appears weak or erratic, the pilot opening may be partially clogged. This should be cleaned by a qualified technician.
- Check Thermocouple: Ensure the thermocouple tip is properly positioned in the pilot flame. A weak or improperly positioned thermocouple can cause the pilot to go out.
- Entegrite Joint: Periodically check the burner door gasket for cracks or damage. A compromised gasket can lead to inefficient operation or gas leaks. Replace if necessary.
Depanaj
If you encounter issues with your Rheem PROTECH SP20075 Pilot Assembly, consult the following common problems and solutions. For complex issues, contact a qualified service technician.
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Pilòt pa pral limen. | No gas supply; clogged pilot tube; faulty igniter. | Ensure gas valve is open. Check for obstructions in pilot tube (professional service recommended). Verify igniter spark. |
| Pilot lights but will not stay lit. | Faulty thermocouple; pilot flame not engulfing thermocouple; low gas pressure. | Replace thermocouple. Adjust pilot flame or thermocouple position. Check gas pressure (professional service required). |
| Main burner does not ignite after pilot is lit. | Thermostat set too low; faulty gas control valve. | Increase thermostat setting. Contact a qualified technician to inspect the gas control valve. |
| Pran sant gaz. | Fwit gaz. | Immediately turn off gas supply and ventilate the area. Do not operate any electrical switches. Contact emergency services and a qualified technician. |
Espesifikasyon
| Karakteristik | Detay |
|---|---|
| Nimewo Modèl | SP20075 |
| Mak | Rheem PROTECH |
| Dimansyon pwodwi | 8.9"W x 2.8"H (approximate, for the assembly) |
| Pwa atik | 7.8 ons |
| Sous pouvwa | Gaz Powered |
| Konpozan ki enkli | Pilot Assembly, Gasket, Screws, Tinnerman Clips, One 8-32 Screw, Instructions |
| Konpatibilite | Select natural gas water heaters |
Enfòmasyon sou Garanti
The Rheem PROTECH SP20075 Pilot Assembly comes with a 1 ane garanti limite. For specific terms, conditions, and to make a warranty claim, please refer to the official Rheem warranty documentation provided with your water heater or contact Rheem customer support.
Sipò pou Kliyan
For further assistance, technical support, or to locate a qualified service professional, please contact Rheem customer service:
- Websit: Visit the official Rheem websit pou jwenn enfòmasyon sou pwodwi ak resous sipò.
- Telefòn: Refer to your water heater's main manual or the Rheem websit pou nimewo kontak sèvis kliyan.
- Sèvis otorize: Always use Rheem authorized service providers for repairs and maintenance to ensure proper functioning and warranty validity.