Pittsburgh 2.5 CFM 1/6 HP Yon Stage Ponp vakyòm

Pittsburgh 2.5 CFM 1/6 HP Yon Stage Manyèl itilizatè ponp vakyòm

Model: 2.5 CFM 1/6 HP One Stage Ponp vakyòm

Entwodiksyon

This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Pittsburgh 2.5 CFM 1/6 HP One Stage Vacuum Pump. Please read this manual thoroughly before operating the pump and retain it for future reference.

The Pittsburgh 2.5 CFM 1/6 HP One Stage Vacuum Pump is designed for deeper vacuum draw, pulling vacuum down to 75 microns. Its precision-machined one-stage pump effectively removes moisture from air conditioning systems, preparing them for safe refrigerant addition. This pump is ideal for automotive air conditioning, HVAC work, and other applications requiring high vacuum pull from a compact unit.

Enfòmasyon enpòtan sou sekirite

Always observe basic safety precautions when using this product to reduce the risk of personal injury and damage to equipment.

  • Li tout enstriksyon anvan ou itilize.
  • Mete ekipman pwoteksyon pèsonèl (PPE) ki apwopriye, tankou linèt sekirite ak gan.
  • Asire w ke zòn travay la byen vantile.
  • Pa fè ponp lan fonksyone nan kondisyon mouye oswa ekspoze li anba lapli.
  • Dekonekte kouran an anvan ou fè nenpòt antretyen oswa sèvis.
  • Use only with specified refrigerants (R134A, R12, R22).

Enstalasyon

Before initial operation, ensure the vacuum pump is placed on a stable, level surface. Check the oil level and fill if necessary with appropriate vacuum pump oil.

Initial Oil Fill/Check

  1. Locate the oil fill cap and sight glass on the pump.
  2. Unscrew the oil fill cap.
  3. Pour vacuum pump oil into the fill port until the oil level is visible in the sight glass, reaching the indicated fill line. Do not overfill.
  4. Remèt bouchon ranpli lwil la byen fèm.

Connecting to an HVAC System

The pump features dual ports for R134A and R12/R22 systems. Use appropriate manifold gauges and hoses for connection.

Pittsburgh 2.5 CFM 1/6 HP Yon Stage Vacuum Pump connected to an HVAC system with manifold gauges.

Figi 1: The Pittsburgh 2.5 CFM 1/6 HP One Stage Vacuum Pump connected to an HVAC system. The image shows the vacuum pump on a wooden deck, connected via yellow and blue hoses to a manifold gauge set. The manifold gauge set is then connected to an outdoor HVAC unit. This setup illustrates a typical vacuuming process for an air conditioning system.

  1. Ensure all valves on the manifold gauge set are closed.
  2. Connect the appropriate vacuum hose from the manifold gauge set to the vacuum pump's inlet port.
  3. Connect the manifold gauge set to the service ports of the HVAC system.
  4. Verifye tout koneksyon yo sere pou anpeche koule.

Enstriksyon Operasyon

Follow these steps for proper operation of the vacuum pump to evacuate an HVAC system.

  1. With the pump connected to the system and manifold gauges, open the manifold gauge valves to the system.
  2. Plug the vacuum pump into a grounded electrical outlet.
  3. Turn on the vacuum pump. The pump will begin to pull a vacuum on the system.
  4. Monitor the vacuum gauge on your manifold set. Allow the pump to run until the desired vacuum level (e.g., 75 microns or lower) is achieved and held steady for a specified period (e.g., 15-30 minutes) to ensure all moisture is removed.
  5. Once the desired vacuum is reached, close the manifold gauge valves to isolate the system from the pump.
  6. Turn off the vacuum pump and then disconnect it from the manifold gauges.
  7. Proceed with refrigerant charging as per HVAC system manufacturer's instructions.

Antretyen

Antretyen regilye asire lonjevite ak pèfòmans optimal ponp vakyòm ou an.

Chanjman lwil oliv

Vacuum pump oil should be changed frequently, especially after each use on a contaminated system or when the oil appears cloudy or discolored. Contaminated oil reduces the pump's ability to pull a deep vacuum.

  1. Ensure the pump is off and unplugged.
  2. Mete yon veso ki apwopriye anba bouchon drenaj lwil la.
  3. Retire bouchon vidman lwil la epi kite tout ansyen lwil la vide nèt.
  4. Replace the oil drain plug securely.
  5. Refill with new, clean vacuum pump oil as described in the "Initial Oil Fill/Check" section.

Netwayaj jeneral

Keep the exterior of the pump clean and free of debris. Do not use harsh chemicals or solvents that could damage the housing.

Depanaj

Seksyon sa a adrese pwoblèm komen ou ka rankontre ak ponp vakyòm ou an.

PwoblèmKòz posibSolisyon
Ponp pa kòmanseNo power; Thermal overload tripped; Motor fault.Check power connection and outlet; Allow pump to cool down; Consult qualified technician.
Pump not pulling sufficient vacuumLow or contaminated oil; Leaks in system/hoses; Clogged inlet filter.Change oil; Check all connections for leaks; Clean/replace inlet filter.
Twòp bri/VibrationLow oil level; Damaged internal components.Check and add oil; Contact customer support for service.

Espesifikasyon

Key technical specifications for the Pittsburgh 2.5 CFM 1/6 HP One Stage Vacuum Pump:

  • Aplikasyon: R134A, R12, R22 refrigerant
  • Pousantaj koule: 2.5 CFM
  • Horsepower (hp): 1 / 6 HP
  • Maksimòm vakyòm: 75 mikron (10 Pascal)
  • Wotè pwodwi: 9 pous.
  • Longè pwodwi: 11-1/4 pous.
  • Lajè pwodwi: 4-3/4 pous.
  • Pwa: 18.25 liv.
  • Gwosè fil: 1/4 in. SAE & 1/2 in.
  • Materyèl Lojman: Durable die cast aluminum
  • Pwoteksyon: Thermal and current overload protection

Garanti ak sipò

Pou enfòmasyon sou garanti a oswa sipò teknik, tanpri al gade nan adrès ofisyèl manifakti a. websit la oubyen kontakte depatman sèvis kliyan yo. Kenbe resi acha w la pou reklamasyon garanti.

Manifakti: Pittsburgh

ASIN: B006ZBAXSW

Dat premye disponib: 4 me 2014

Pou plis asistans, ou ka vizite paj pwodwi sou Amazon.com.

Dokiman ki gen rapò - 2.5 CFM 1/6 HP Yon Stage Ponp vakyòm

Preview Manyèl Pwopriyetè ak Enstriksyon Sekirite pou Twous Kalib Manifoul A/C Pittsburgh la
This manual provides safety instructions, specifications, applications, operation, and maintenance for the Pittsburgh A/C Manifold Gauge Set. It details how to safely use the gauge set for automotive air conditioning systems, including procedures for diagnostic checks, recovery/evacuation, and charging.
Preview Manyèl Pwopriyetè Twous Zouti Double Flaring Pittsburgh ak Enstriksyon Sekirite
This manual provides safety warnings, assembly, operating, inspection, maintenance, and cleaning procedures for the Pittsburgh Double Flaring Tool Kit. It includes specifications, important safety information, operating instructions, maintenance and servicing guidelines, and a parts list and diagram.
Preview Manyèl Pwopriyetè ak Enstriksyon Sekirite pou Kalipè Dijital Konpoze PITTSBURGH 6" la
Manyèl sa a bay avètisman sekirite, prekosyon, asanblaj, operasyon, enspeksyon, antretyen, ak pwosedi netwayaj pou PITTSBURGH 6" Composite Digital Caliper la. Li gen ladan enfòmasyon enpòtan sou sekirite, deskripsyon konpozan, enstriksyon operasyon, ak detay sou garanti.
Preview Pittsburgh Dual Power Home 120V/Auto 12V Tire Inflator with LED Light - Owner's Manual & Safety Instructions
Comprehensive owner's manual and safety instructions for the Pittsburgh Dual Power Home 120V/Auto 12V Tire Inflator with LED Light. Covers operation, maintenance, troubleshooting, and warranty information.
Preview Pittsburgh 8" Three-Jaw Puller Owner's Manual & Safety Instructions
Owner's manual and safety instructions for the Pittsburgh 8-inch Three-Jaw Puller (Model 63952). Includes setup, assembly, operating procedures, maintenance, parts list, and warranty information from Harbor Freight Tools.
Preview Pittsburgh Hydraulic Jack: Important Pre-Operation Instructions
Read these critical pre-operation instructions for Pittsburgh hydraulic jacks to ensure safe and proper use. Includes contact details for technical support.