Extech PH110

Extech PH110 Waterproof ExStik pH Meter Instruction Manual

Brand: Extech | Model: PH110

1. Entwodiksyon

The Extech PH110 Waterproof ExStik pH Meter is designed for accurate pH measurements in various substances. This device features a refillable pH electrode, allowing for extended use and consistent accuracy by replenishing the reference solution. Its robust, waterproof design ensures reliability in diverse environments.

2. Karakteristik kle

  • Refillable pH electrode for extended service life.
  • Analog bargraph display on LCD for trend indication.
  • Waterproof construction to IP57 standard.
  • Automatic 1, 2, or 3 point calibration with buffer solution recognition.
  • Flat Surface Electrode capable of measuring pH in liquids, semi-solids, and solids.

3. Pake kontni

The Extech PH110 Waterproof ExStik pH Meter package includes:

  • Extech PH110 pH Meter with refillable pH electrode
  • 1.5mL bottle of KCI (Potassium Chloride) solution
  • Two reference junctions
  • Two electrode removal tools
  • Bouchon pwoteksyon
  • Sample cup
  • Four 3V CR-2032 batteries (pre-installed or included separately)
  • Braslè kou 48 pous (1.2m)

4. Enstalasyon

4.1 Enstalasyon batri

  1. Ensure the meter is off.
  2. Jwenn lòj batri a.
  3. Insert four 3V CR-2032 Lithium Metal batteries, observing correct polarity.
  4. Byen fèmen lòj batri a.

4.2 Preparasyon Elektwòd

  1. Retire bouchon pwoteksyon an nan elektwòd la.
  2. Rinse the electrode tip with distilled water.
  3. If the electrode appears dry, soak it in electrode storage solution or pH 7 buffer for at least 30 minutes before first use.

5. Operasyon

5.1 Kalibrasyon

Calibration is essential for accurate measurements. The PH110 supports 1, 2, or 3 point calibration and automatically recognizes buffer solutions.

  1. Turn on the meter by pressing the ON/OFF bouton.
  2. Prepare fresh pH buffer solutions (e.g., pH 4, 7, and 10). These are sold separately.
  3. Peze epi kenbe la CAL button until 'CAL' appears on the display.
  4. Immerse the electrode into the first buffer solution (e.g., pH 7). The meter will automatically recognize the buffer and calibrate. Wait for the reading to stabilize.
  5. For 2 or 3 point calibration, rinse the electrode with distilled water and immerse it into the next buffer solution (e.g., pH 4, then pH 10). The meter will continue to calibrate automatically.
  6. Ensure the display shows 'CAL' during the calibration process.

5.2 Mezi

The flat surface electrode allows for versatile measurements.

  1. After calibration, rinse the electrode with distilled water.
  2. Plonje elektwòd la nan s laample to be measured. For liquids, ensure the electrode tip is fully submerged. For semi-solids or solids, ensure good contact with the flat surface electrode.
  3. Allow the reading to stabilize on the display. The analog bargraph will indicate trends in acidity or alkalinity.
  4. To switch between pH and temperature display modes, press the MÒD bouton.
  5. After measurement, rinse the electrode thoroughly with distilled water and replace the protective cap.
Extech PH110 Waterproof ExStik pH Meter displaying a pH reading.

Figi 1: The Extech PH110 pH meter, a handheld device with a digital display showing pH and temperature readings. It features three control buttons: MODE, CAL, and ON/OFF.

6. Antretyen

6.1 Electrode Refilling

The refillable electrode design allows for prolonged accuracy and lifespan.

  1. When the reference solution depletes or accuracy declines, use the provided removal tools to access the reference junctions.
  2. Carefully refill the electrode with the 1.5mL KCI solution.
  3. Ensure the reference junctions are properly re-seated after refilling.
Hands refilling the Extech PH110 pH meter electrode with filling solution.

Figi 2: Yon fèmen view of hands refilling the Extech PH110 pH meter's electrode module with a specialized electrode filling solution from a small bottle. This process ensures the meter's continued accuracy and extends electrode life.

6.2 Netwayaj ak Depo

  • Always rinse the electrode with distilled water after each use to prevent contamination.
  • The flat surface electrode is designed for easy cleaning. Gently wipe with a soft cloth if necessary.
  • Store the electrode with its protective cap filled with electrode storage solution (or pH 7 buffer if storage solution is unavailable) to keep the sensor hydrated. Do not store dry.

NAN. Depanaj

If the meter exhibits inaccurate readings or operational issues, consider the following:

  • Lekti ki pa kòrèk: Recalibrate the meter using fresh buffer solutions. Ensure the electrode is clean and properly hydrated. Check if the reference solution in the electrode needs refilling.
  • Pa gen pwoblèm ekspozisyon/kouran: Verify that the batteries are correctly installed and have sufficient charge. Replace batteries if necessary.
  • Repons Ralanti: The electrode might be dry or contaminated. Clean and rehydrate the electrode, then recalibrate.

8. Espesifikasyon

SpesifikasyonDetay
ManifaktiExtech
Nimewo PatiPH110
Pwa atik3.87 ons
Dimansyon pwodwi6.8 x 1.6 x 1.4 pous
Nimewo Modèl AtikPH110
Batri4 Lithium Metal batteries (CR-2032) required (included)
Sous pouvwaBatri Powered
Evalyasyon ki enpèmeyabIP57 estanda
Kalibrasyon1, 2, or 3 point automatic buffer recognition
Kalite elektwòdRefillable Flat Surface Electrode

9. Enfòmasyon sou Garanti

Extech provides a full one-year warranty on parts and workmanship for the PH110 pH Meter, unless otherwise specified. This warranty does not cover defects resulting from user actions such as misuse, improper wiring, operation outside of specified parameters, improper maintenance or repair, or unauthorized modifications.

10. Sipò

For further assistance, technical support, or to purchase accessories and replacement parts, please refer to the official Extech Instruments websit la oubyen kontakte depatman sèvis kliyan yo. Anjeneral, ou ka jwenn enfòmasyon pou kontakte yo sou anbalaj manifakti a oubyen websit.

Dokiman ki gen rapò - PH110

Preview Gid Itilizatè pou Mèt pH ki Enpèmeyab Extech ExStik™ PH100 ​​ak PH110
Gid konplè pou itilizatè a pou mèt pH Extech ExStik™ ki enpèmeyab yo, modèl PH100 ​​ak PH110. Aprann plis sou operasyon, kalibrasyon, antretyen ak espesifikasyon yo.
Preview Extech ExStik Waterproof pH Meters PH100 & PH110 User Manual
Comprehensive user manual for the Extech ExStik Waterproof pH Meters, models PH100 and PH110. Provides detailed instructions on operation, calibration, electrode maintenance, battery replacement, safety precautions, specifications, and troubleshooting for these high-accuracy pH testing devices.
Preview Manyèl Itilizatè Extech ExStik II EC400 Konduktivite, TDS, Salinite, Mèt Tanperati
Manyèl itilizatè konplè pou mèt Extech ExStik II EC400 la, ki detaye karakteristik li yo pou mezire konduktivite, total solid ki fonn (TDS), salinite, ak tanperati. Gen ladan l konfigirasyon, operasyon, kalibrasyon, antretyen, depanaj, ak espesifikasyon yo.
Preview Katalòg konplè Extech: Mèt anviwònman, Anemomèt, ak Ekipman Tès
Eksplore pakèt mèt anviwònman kalite siperyè Extech yo, tèmo-anemomèt, detektè gaz, aparèy pou teste kalite dlo, sonmèt, limyèmèt, ak lòt enstriman tès ak mezi presizyon ki fèt pou aplikasyon endistriyèl, HVAC/R, ak pwofesyonèl.
Preview Extech PH220 Waterproof Palm pH Meter User Manual
User manual for the Extech PH220 Waterproof Palm pH Meter. Covers introduction, meter description, operation, calibration, measurement, storage, battery replacement, maintenance, troubleshooting, and specifications.
Preview Manyèl Itilizatè EXTECH 45170 4-an-1 Imidite, Tanperati, Koule Lè, ak Limyè
Manyèl itilizatè pou EXTECH 45170 la, yon mèt 4 an 1 ki mezire imidite, tanperati, koule lè ak limyè. Gen ladan l enfòmasyon sou operasyon, espesifikasyon ak garanti.