1. Entwodiksyon
The Extech 382252 is a comprehensive Earth Ground Resistance Tester Kit designed for accurate measurement of earth ground resistance. This kit provides three selectable ranges for earth ground resistance: 20 Ohms (Ω), 200 Ohms (Ω), and 2000 Ohms (Ω). Beyond earth ground testing, the device also functions as a multimeter, capable of measuring AC/DC Voltage, Resistance, and Continuity. It features automatic zero adjustment for ease of use. This manual provides detailed instructions for the safe and effective operation, maintenance, and troubleshooting of your Extech 382252.
2. Enfòmasyon sou Sekirite
Avètisman: Improper use of this meter can cause damage, shock, injury, or death. Read and understand all safety information and operating instructions before using this instrument. Always adhere to local and national safety codes.
- Pa depase limit maksimòm opinyon yo pou okenn fonksyon.
- Fè anpil atansyon lè w ap travay ak sikui elektrik ki anba kouran.
- Ensure the meter is in good working condition and free from damage before use.
- Always use the correct function and range for measurements.
- Ranplase pil yo lè endikatè pil fèb la parèt pou asire lekti yo egzak.
- Keep hands and fingers away from test probe tips when making measurements.
- Pa sèvi ak mèt la nan atmosfè eksplozif oswa nan prezans gaz oswa pousyè ki ka pran dife.
3. Pake kontni
Verifye ke tout atik yo prezan epi yo pa domaje lè w ap debale yo:
- Extech 382252 Earth Ground Resistance Tester
- Test Leads (set)
- Auxiliary Earth Bars (2 pieces)
- Ka pote
- Protective Rubber Holster
- 1.5V AA Batteries (6 pieces)

Image 1: The Extech 382252 Earth Ground Resistance Tester Kit, showing the main unit, test leads, two auxiliary earth bars, and the carrying case.
4. Pwodwi Features
The Extech 382252 offers the following key features:
- Earth Ground Resistance measurement in three ranges: 20Ω, 200Ω, and 2000Ω.
- AC / DC Voltagkapasite mezi e.
- Resistance and Continuity testing functions.
- Automatic zero adjustment for accurate readings.
- Gwo, fasil-a-li LCD ekspozisyon.
- Fonksyon Data Hold pou bloke lekti ki parèt yo.
- Limyè dèyè pou vizibilite nan kondisyon ki pa klere anpil.
- Durable protective rubber holster.

Imaj 2: Devan view of the Extech 382252 Earth Ground Resistance Tester, highlighting its display, function dial, and control buttons.
5. Enstalasyon
5.1 Enstalasyon batri
- Ensure the meter is powered off.
- Jwenn kouvèti konpatiman pil la sou dèyè mèt la.
- Use a screwdriver to remove the screw(s) securing the cover.
- Insert six (6) 1.5V AA batteries, observing correct polarity (+/-).
- Remèt kouvèti konpatiman batri a epi byen sere l ak vis(yo).
5.2 Konekte fil tès yo
Connect the test leads to the appropriate input jacks on the meter for the desired measurement function. For earth ground resistance testing, specific connections involving the auxiliary earth bars will be detailed in the operating instructions.
6. Operasyon Enstriksyon
6.1 Power On/Off
Rotate the function dial from the 'OFF' position to any desired measurement function to power on the meter. To power off, rotate the dial back to the 'OFF' position.
6.2 Automatic Zero Adjustment
The meter features automatic zero adjustment. When selecting a resistance range, the meter will automatically adjust to zero, compensating for lead resistance. Ensure test leads are not shorted or open during this process for accurate zeroing.
6.3 Fonksyon kenbe done
Press the 'HOLD' button to freeze the current reading on the display. Press it again to release the hold and resume live readings.
6.4 Fonksyon ekleraj dèyè
Press the backlight button (often indicated by a light bulb icon) to illuminate the display for better visibility in dark environments. Press it again to turn off the backlight.
7. Earth Ground Resistance Measurement
The Extech 382252 uses the 3-wire (or Fall-of-Potential) method for earth ground resistance measurements. This method requires the use of the two auxiliary earth bars provided.
7.1 Measurement Procedure (3-Wire Method)
- Preparasyon: Ensure the circuit under test is de-energized and safely isolated.
- Placement of Auxiliary Earth Bars:
- Drive the first auxiliary earth bar (P) into the ground at a suitable distance from the earth electrode (E) being tested.
- Drive the second auxiliary earth bar (C) into the ground at a further distance from P, ensuring all three points (E, P, C) are in a straight line. Typical distances are 5-10 meters (15-30 feet) between E and P, and P and C, but may vary based on soil conditions and electrode size.
- Konekte fil tès yo:
- Connect the 'E' terminal of the meter to the earth electrode under test.
- Connect the 'P' terminal of the meter to the first auxiliary earth bar (P).
- Connect the 'C' terminal of the meter to the second auxiliary earth bar (C).
- Chwazi ranje: Rotate the function dial to the desired Earth Ground Resistance range (20Ω, 200Ω, or 2000Ω). Start with the highest range if the resistance value is unknown.
- Fè tès la: Press the 'TEST' button. The meter will inject a current and measure the voltage drop to calculate the earth ground resistance.
- Li Mezi: The resistance value will be displayed on the LCD.
- Verify Accuracy: For critical measurements, it is recommended to repeat the test with the auxiliary earth bars placed at slightly different distances to ensure the reading is stable and accurate.
8. Other Measurements
8.1 AC/DC Voltage Mezi
- Connect the red test lead to the 'V' input jack and the black test lead to the 'COM' input jack.
- Rotate the function dial to the desired ACV (750V AC) or DCV (1000V DC) range.
- Konekte sond tès yo atravè sikwi a oswa konpozan ki pral mezire a.
- Li voltage valè sou ekspozisyon an.
8.2 Mezi rezistans
- Asire w ke sikwi a oswa konpozan an pa gen enèji.
- Connect the red test lead to the 'V' input jack and the black test lead to the 'COM' input jack.
- Rotate the function dial to the desired Resistance range (e.g., 200Ω, 20kΩ, 200kΩ).
- Konekte sond tès yo atravè konpozan an.
- Li valè rezistans nan ekspozisyon an.
8.3 Tès kontinwite
- Asire w ke sikwi a oswa konpozan an pa gen enèji.
- Connect the red test lead to the 'V' input jack and the black test lead to the 'COM' input jack.
- Rotate the function dial to the Continuity position (often indicated by a speaker icon).
- Connect the test probes across the component or wire.
- Yon bip sonnen endike kontinwite (rezistans ki ba). Ekran an ap montre valè rezistans lan.
9. Antretyen
9.1 Netwayaj
Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents. Periodically clean the test leads and probes to ensure good electrical contact.
9.2 Ranplasman batri
When the low battery indicator appears on the display, replace the batteries promptly to maintain measurement accuracy. Refer to Section 5.1 for battery installation instructions.
9.3 Depo
If the meter is to be stored for an extended period, remove the batteries to prevent leakage and damage. Store the meter in its carrying case in a cool, dry environment, away from direct sunlight and extreme temperatures.
NAN. Depanaj
- No Display/Meter Not Powering On: Check battery installation and ensure batteries are fresh. Verify the function dial is not in the 'OFF' position.
- Lekti ki pa kòrèk: Ensure test leads are properly connected and not damaged. Check battery level. For earth ground resistance, verify proper placement and connection of auxiliary earth bars and ensure good contact with the ground.
- Pa gen bip kontinuite: Check if the circuit is truly continuous. Ensure test leads are making good contact.
- Display Shows 'OL' (Overload): Valè mezire a depase limit ki chwazi a. Chanje nan yon limit ki pi wo.
If issues persist after following these steps, contact customer support.
11. Espesifikasyon
| Spesifikasyon | Valè |
|---|---|
| Mak | Extech |
| Nimewo Modèl | 382252 |
| Earth Ground Resistance Ranges | 20Ω, 200Ω, 2000Ω |
| AC Voltage Range | Jiska 750V AC |
| DC Voltage Range | Jiska 1000V DC |
| Ranje Rezistans | 20Ω, 200Ω, 20kΩ, 200kΩ (typical, check device for full ranges) |
| Presizyon Mezi | +/-0.5% (for certain functions, refer to product manual for specifics) |
| Sous pouvwa | 6 x 1.5V batri AA |
| Pwa atik | 0.69 kilogram (1.52 liv) |
| Dimansyon pwodwi (L x W x H) | 7.9 x 3.6 x 2 pous |
| Konpozan ki enkli | Test leads, 2 earth bars, carrying case, holster, six 1.5V AA batteries |
| Rating sekirite | CAT III 1000V, CE |
12. Garanti
The Extech 382252 Earth Ground Resistance Tester Kit typically comes with a 1-ane garanti limite from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from misuse, accident, unauthorized repair, or modification. Please retain your proof of purchase for warranty claims.
13. Sipò
For technical assistance, calibration services, or further information regarding your Extech 382252, please refer to the official Extech website or contact their customer support department. Contact details can usually be found on the manufacturer's websit la oubyen nan dokimantasyon ki vini ak pwodwi ou a.