1. Entwodiksyon ak souview
This manual provides essential information for the safe and effective installation, operation, and maintenance of the Square D Homeline 30 Amp 2-Pole Circuit Breaker, model HOM230CP. This device is designed to provide reliable residential circuit protection against overloads and short circuits.
The HOM230CP is a standard type, plug-in mount circuit breaker suitable for residential use in Square D Homeline load centers and CSEDs. It features a 30A current rating, 10kA breaking capacity, and operates on 120/240V AC circuits, making it ideal for larger appliances.
2. Enfòmasyon sou Sekirite
AVÈTISMAN: Risk chòk elektrik oswa dife.
- Se sèlman pèsonèl elektrik kalifye ki dwe fè enstalasyon ak antretyen disjonktè sa a.
- Always turn off the main power supply at the service panel before installing or servicing any electrical equipment.
- Sèvi ak ekipman pwoteksyon pèsonèl (PPE) ki apwopriye lè w ap travay ak sistèm elektrik yo.
- Ensure all connections are tight and secure to prevent overheating and potential fire hazards.
- Pa sèvi ak disjonktè sa a pou aplikasyon ki depase vòltaj espesifye li a.tage oswa evalyasyon aktyèl yo.
- This product is UL-listed for safety and reliability. Adhere to all local and national electrical codes.
3. Pwodwi Features
- Pwoteksyon Sikwi Rezidansyèl: Engineered for fast installation and superior circuit protection in homes.
- Enstalasyon fasil: Plug-on neutral design with a shorter footprint for quick plug-in mounting.
- 30 Amp Konfigirasyon De-Pòl: Delivers 30A protection, suitable for 240V branch circuits powering larger appliances like dryers, ranges, and air conditioners.
- Pwoteksyon Estanda: Offers standard thermal/magnetic protection against overloads and short circuits.
- HACR Rated: Suitable for use with air conditioning, heating, and refrigeration equipment.
- Fil konpatibilite: Clamp terminal accepts 2 wires, ranging from 14 AWG to 8 AWG copper or aluminum wire.

Image 1: Technical benefits of the Square D Homeline 30 Amp 2-Pole Circuit Breaker, highlighting its 30A rating, overload/short-circuit protection, UL certification, 10kA breaking capacity, residential/commercial use, and compatibility with Homeline panels.
4. Espesifikasyon
| Nimewo Modèl | HOM230CP |
| Mak | Schneider Electric (Square D Homeline) |
| Rating aktyèl | 30 Amps |
| Kantite poto | 2 |
| Voltage Rating | 120 / 240V AC |
| Kapasite kraze | 10kA |
| Kalite aliye | Ploge nan mòn |
| Kalite Circuit Breaker | Estanda, Tèmik/Mayetik |
| Konpatibilite kalib fil | 14 AWG to 8 AWG (Copper or Aluminum) |
| Sètifikasyon | Lis UL, evalyasyon HACR |
| Dimansyon (H x W x P) | 3.13" x 2" x 2.98" (79.50 mm x 50.8 mm x 75.69 mm) |

Image 2: Detailed dimensions of the HOM230CP circuit breaker, showing its height (3.13"), width (2"), and depth (2.98").
5. Enstalasyon (Enstalasyon)
The Square D Homeline HOM230CP circuit breaker is designed for easy installation in compatible Square D Homeline load centers and CSEDs. It occupies two spaces within the panel.
Etap enstalasyon:
- Ensure Power is OFF: Before beginning any work, locate the main service disconnect and turn off all power to the electrical panel. Verify with a voltagtèsteur e ke pa gen kouran.
- Idantifye Kote yo: Select two adjacent available spaces in your Square D Homeline load center or CSED for the 2-pole breaker.
- Konekte fil yo: Connect the two circuit wires (typically black and red for 240V circuits) to the clamp terminals on the circuit breaker. The clamp terminals accept 14 AWG to 8 AWG copper or aluminum wire. Ensure wires are stripped to the correct length and inserted fully into the terminals. Tighten the terminal screws securely according to manufacturer specifications (refer to the load center's label for torque values).
- Mount Breaker: Align the circuit breaker's clips with the bus bar stabs in the load center. Press firmly until the breaker snaps securely into place. The plug-on neutral design ensures a proper connection.
- Verifye Koneksyon: Double-check all wire connections and ensure the breaker is firmly seated.
- Retabli pouvwa: Once installation is complete and verified, close the electrical panel cover. Restore power at the main service disconnect.
For optimal safety and compliance with electrical codes, it is highly recommended that installation be performed by a licensed electrician.

Image 3: The HOM230CP circuit breaker shown with compatible Homeline electrical panels and CSEDs, indicating its plug-in compatibility.
6. Operasyon
The HOM230CP circuit breaker functions as an automatic protective device for your electrical circuits. It has two primary operating states:
- ON Pozisyon: When the handle is in the 'ON' position, power is supplied to the connected circuit.
- OFF Pozisyon: When the handle is in the 'OFF' position, power to the connected circuit is interrupted. This position is used for manual disconnection or during maintenance.
- Pozisyon DEKLÒCHE: If an overload or short circuit occurs, the breaker will automatically move to a central 'TRIPPED' position (often indicated by the handle being between ON and OFF). This indicates that the circuit has been safely interrupted to prevent damage or fire.
7. Antretyen
The Square D Homeline HOM230CP circuit breaker is a sealed unit and contains no user-serviceable parts. Regular maintenance is generally not required beyond periodic visual inspection.
Antretyen Rekòmande:
- Enspeksyon vizyèl: Periodically inspect the circuit breaker and its connections within the load center for any signs of damage, discoloration, loose wires, or corrosion.
- Retire pousyè: Ensure the area around the circuit breaker within the electrical panel is clean and free of dust and debris, which can impede heat dissipation.
- Tcheke pwofesyonèl: Consider having a qualified electrician inspect your electrical panel and circuit breakers every few years to ensure continued safe operation.
Do not attempt to open or repair the circuit breaker. If the breaker appears damaged or malfunctions, it should be replaced by a qualified professional.
NAN. Depanaj
If your HOM230CP circuit breaker trips, it indicates a protective action against an electrical fault. Follow these steps:
Deklanchman disjoncteurs:
- Identify Tripped Breaker: Locate the HOM230CP breaker in your electrical panel. Its handle will be in the 'TRIPPED' (middle) position.
- Turn OFF Affected Appliances: Disconnect or turn off all appliances and devices connected to the tripped circuit.
- Reyajiste Breaker: Firmly push the breaker handle all the way to the 'OFF' position, then push it back to the 'ON' position.
- Restore Appliances: Gradually plug in and turn on appliances one by one to identify if a specific device caused the trip.
- Persistent Tripping: If the breaker trips immediately after resetting, or trips frequently, it indicates a persistent electrical fault (e.g., a short circuit, ground fault, or consistent overload). In such cases, do not attempt further resets. Contact a qualified electrician immediately to diagnose and repair the issue.
Never force a circuit breaker handle to stay in the 'ON' position if it continues to trip. This can lead to serious electrical hazards.
9. Garanti ak sipò
The Square D Homeline HOM230CP circuit breaker is covered by a manufacturer's warranty. For specific warranty details, terms, and conditions, please refer to the documentation provided with your purchase or visit the official Schneider Electric websit.
For technical support, product inquiries, or assistance with warranty claims, please contact Schneider Electric customer service directly. Contact information can typically be found on the manufacturer's websit la oubyen sou anbalaj pwodwi a.
Ofisyèl Schneider Electric Websit: www.se.com/us/en/