OOYCYOO P60

OOYCYOO MPPT Solar Charge Controller User Manual

Model: P60 (60A Variant)

Brand: OOYCYOO

1. Entwodiksyon

This manual provides detailed instructions for the installation, operation, and maintenance of your OOYCYOO MPPT Solar Charge Controller. This device is designed to efficiently manage power flow from your solar panels to your battery bank, ensuring optimal charging and extending battery life. Please read this manual thoroughly before installation and use.

Devan view of OOYCYOO MPPT Solar Charge Controller with LCD display and terminals.
Figure 1: OOYCYOO MPPT Solar Charge Controller (Front View)

2. Karakteristik kle

  • Advanced Maximum Power Point Tracking (MPPT) technology with efficiency no less than 99% and conversion efficiency of 98.5%.
  • Automatic identification of 12V/24VDC system voltage.
  • Blacklight LCD panel display for dynamic display of operating data and working conditions.
  • Support for 3 charging lead-acid battery options: Sealed, Gel, Flooded.
  • Fonksyon konpansasyon tanperati batri.
  • Wide MPP opere voltage ranje.
  • High-quality components for perfecting system performance.
  • Ultra-fast tracking speed and great tracking efficiency.
  • Built-in protection functions: overcharge, overdischarge, overload, overheat, reverse polarity, and lightning protection.
  • Two new vents for scientifically designed convection cooling.
  • Maximum DC/DC transfer efficiency up to 98.7%.
List of MPPT Controller features and application icons.
Figi 2: Plis paseview of Controller Features and Applications
Internal components, cooling fan, and port design of the MPPT controller, along with various application scenarios like RVs, boats, and homes.
Figure 3: Internal Design and Application Examples

3. Enfòmasyon sou Sekirite

WARNING: Improper installation or operation can lead to serious injury or damage to the equipment. Always follow safety guidelines.

  • Ensure the battery is at least 60% charged before connecting to the controller.
  • Always connect the battery to the controller FIRST.
  • NEVER connect your solar panel array to the controller without a battery connected.
  • Ensure your input power and voltage do not exceed the maximum ratings specified in the specifications section.
  • The controller provides protection against overcharge, overdischarge, overload, overheat, reverse polarity, and lightning. However, proper installation is crucial for these features to function effectively.
  • Do not connect inverters/inductive loads directly to the controller's load port.

4. Pake kontni

Lè w ap ouvri pake a, tanpri verifye ke tout atik yo prezan epi yo pa domaje:

  • 1 x MPPT Solar Charge Controller (P60A)
  • 1 x Capteur Tanperati
  • 1 x Manyèl Itilizatè (Angle)
Product packaging showing the MPPT solar charge controller, temperature sensor, and user manual.
Figi 4: Sa ki pakè

5. Enstalasyon ak fil elektrik

Swiv etap sa yo ak anpil atansyon pou yon enstalasyon kòrèk:

  1. **Prepare Wires:** Turn the adjusting screw counterclockwise on the terminal block until the plate moves downward. Peel off the insulation coating of the cable tip by about 8 to 10 mm.
  2. **Connect Battery:** Insert the prepared wire into the new opening between the plate and the "top" of the terminal hole. Turn the adjuster clockwise; the plate moves upward and crushes the wire in the hole of the terminal. Ensure all connections are tight. Always connect the battery first.
  3. **Connect Solar Panels:** After the battery is securely connected, connect the solar panel array to the designated terminals. Ensure correct polarity.
  4. **Connect Load:** Finally, connect your DC loads to the load terminals.
  5. **Verify Connections:** Double-check all connections for tightness and correct polarity before powering on the system.

REMAK ENPÒTAN:

  • Make sure your battery must be at least 60% charged prior to connecting to controller.
  • Always connect your battery first.
  • Never connect your solar panel array to the controller without a battery.
  • Atansyon pouvwa D' ou ak voltage does not exceed the max.
Detailed wiring diagram showing connections for solar panels, battery, DC loads, and an inverter for AC loads.
Figi 5: Dyagram Fil elektrik Sistèm
Simplified wiring diagram with important notes on connection order and battery charge level.
Figure 6: Simplified Wiring Diagram with Important Notes

6. Operasyon Enstriksyon

6.1 LCD Display Entèfas

The controller features a blacklight LCD display that shows various real-time data and working conditions. The display provides information such as PV voltage, batri voltage, load current, charging status, and more.

Detailed description of the LCD operating interface with numbered labels for each displayed parameter.
Figure 7: LCD Operating Interface Description

Key indicators on the LCD:

  • **1. Charging failure:** Indicates an issue with the charging process.
  • **2. Charging logo:** Shows when the battery is being charged.
  • **3. Solar panels:** Displays solar panel status.
  • **4. Solar panel voltages and currents:** Real-time readings from the PV array.
  • **5. Battery voltage and current:** Real-time battery status.
  • **6. Evening System Status:** Indicates system status during evening hours.
  • **7. Load stops working hours:** Displays the duration the load has been off.
  • **8. Charging stops voltage:** The voltage at which charging ceases.
  • **9. Ambient temperature and battery capacity percentage:** Environmental temperature and battery charge level.
  • **10. Discharge stop voltage:** The voltage at which discharge to load ceases.
  • **11. Discharge identity / Discharge fault:** Indicates load discharge status or issues.
  • **12. Load and state:** Shows load status (ON/OFF).
  • **13. Load voltage and current:** Real-time readings for the connected load.
  • **14. Dawn System Status:** Indicates system status during dawn hours.
  • **15. Undervoltage restore voltage:** The voltage at which the load will be reconnected after undervoltage pwoteksyon.

Note: The cumulative power generation KHW of the solar power system is shown in position 9. After the battery is disconnected, the power generation KWH is cleared.

6.2 Bouton Kontwòl

The controller has several buttons for navigation and control:

Close-up of the LCD display and control buttons: Toggle key, Plus, Minus, and Manual switch load.
Figure 8: Control Buttons
  • **Toggle Key:** Used to cycle through different display parameters (PV OFF → LOAD OFF → LOAD ON → Evening → Interval → Dawn). This button also allows setting the order of the automatic cycle.
  • **'+' (Plus) Key:** Used to increase values when setting parameters.
  • **'-' (Minus) Key:** Used to decrease values when setting parameters.
  • **Manual Switch Load Key:** This button can be used to manually open or close the load.
  • **5S Reset:** Press and hold the reset button for 5 seconds to restore factory settings.

All the various real-time data is shown on one display, making it convenient for the user to check.

7. Antretyen

Pou asire pèfòmans optimal ak lonjevite Kontwolè Chaj Solè MPPT ou a, li rekòmande pou fè antretyen regilye:

  • **Cleanliness:** Keep the controller clean and free from dust and debris. Ensure the cooling vents are not obstructed to allow for proper heat dissipation.
  • **Connections:** Periodically check all wiring connections (solar panels, battery, load) to ensure they are tight and free from corrosion. Loose connections can lead to power loss or damage.
  • **Environment:** Ensure the controller is installed in a dry, well-ventilated area, away from direct sunlight and extreme temperatures.
  • **Battery Health:** Monitor your battery's health and ensure it is compatible with the controller's charging profiles.

NAN. Depanaj

This section provides guidance for common issues you might encounter. Refer to the LCD display for error indicators.

Pwoblèm Kòz posib Solisyon
Pa gen ekspozisyon sou LCD No power from battery or solar panel; loose battery connection. Check battery connections and ensure battery has sufficient charge. Verify solar panel connection.
Battery not charging (Charging failure indicator) Solar panel not connected, insufficient sunlight, faulty solar panel, incorrect battery type setting. Check solar panel connections and ensure adequate sunlight. Verify solar panel output. Confirm correct battery type is selected in settings.
Load not working (Discharge failure indicator) Batri undervoltage, overload, loose load connection, load switch off. Tcheke batri voltage; if low, allow battery to charge. Reduce load. Check load connections. Ensure manual load switch is ON.
Pwoteksyon surchof deklanche Poor ventilation, excessive ambient temperature, controller overloaded. Ensure controller is in a well-ventilated area. Reduce load if necessary. Allow controller to cool down.
Sistèm voltage not automatically identified Batri voltage outside 12V/24V auto-identification range. Asire batri voltage is within the expected range for 12V or 24V systems.

9. Espesifikasyon

Paramèt Detay
Non mak OOYCYOO
Nimewo Modèl P60
Current (Rated Charge) 60A
Sistèm nominal Voltage 12V/24VDC Auto Identifying
Max. PV Open Circuit Voltage 100VDC
Batri Voltage Range 9V-32V
Pouvwa Tèminal 10 AWG
Orijin Lachin tè pwensipal
Sètifikasyon CE
Dimansyon (L x W x H) 10.82 x 7.36 x 3.34 pous (apeprè)
Pwa 5 LB (approx.)

9.1 Max. PV Input Power by System Voltage

Sistèm Volim Sikwi Ouvè Panèl Solètage (Voc) Max. Pouvwa Voltage (Vmp) Max. PV Input Power (60A Controller)
12V sistèm ≤ 48V (Voc) ≤ 36V (Vmp) 750W
24V sistèm ≤ 96V (Voc) ≤ 72V (Vmp) 1500W
Table showing system voltage, solar panel open circuit voltage, max power voltage, and max PV input power for 40A and 60A controllers.
Figure 9: Max PV Input Power Table

10. Garanti ak sipò

For any technical assistance, warranty claims, or product inquiries, please contact OOYCYOO customer support. Refer to your purchase documentation for specific warranty terms and contact details.

The manufacturer provides professional technical team guidance for installation and support.

Dokiman ki gen rapò - P60

Preview Ooycyoo MPPT 'P' Series 40A/60A Solar Charge Controller User Manual
Explore the Ooycyoo MPPT 'P' Series 40A/60A Solar Charge Controller. This user manual details advanced MPPT technology, features like real-time display, USB charging, and multi-stage battery charging, along with essential safety and installation guidance for solar energy systems.
Preview OOYCYOO MPPT Solar Power Generation System Controller User Manual
This document provides comprehensive instructions and technical specifications for the OOYCYOO MPPT Solar Power Generation System Controller. Learn about installation, parameter settings, protection features, and system wiring for optimal solar energy utilization.
Preview RF Test Report: P60 Mobile Phone (FCC ID: 2ALJJP60) - Emission, Power, and Stability
Comprehensive RF test report detailing emission bandwidth, occupied bandwidth, frequency stability, and peak/average power measurements for the P60 mobile phone (FCC ID: 2ALJJP60). Includes data from Shenzhen Tongzhou Testing Co., Ltd.
Preview Gid rapid CORN P60 - Enfòmasyon sou enstalasyon ak sekirite
Yon gid HTML kout e optimize pou SEO pou smartphone CORN P60 la, ki kouvri premye konfigirasyon an, mete kat SIM, prekosyon sekirite, ak enfòmasyon konfòmite FCC.
Preview XGODY P60 Pro Android Tablet Quick Start Manual
Get started with your XGODY P60 Pro Android Tablet. This quick start manual provides essential information on setup, maintenance, and basic operations.