Copeland XR02CX-5N0C1

Copeland XR02CX-5N0C1 Temperature Controller

Manyèl Enstriksyon Itilizatè

1. Entwodiksyon

This manual provides detailed instructions for the installation, operation, and maintenance of the Copeland XR02CX-5N0C1 Temperature Controller. This device is designed for precise temperature management in refrigeration and freezing units, offering single output control for compressors and defrosting functions. Please read this manual thoroughly before installation and operation to ensure safe and efficient use.

2. Pwodwi souview

The XR02CX-5N0C1 is a compact and reliable temperature controller, featuring a clear digital display and intuitive controls. It is suitable for a wide range of indoor refrigeration applications.

2.1 Karakteristik kle

  • Single output for compressor control and shutdown defrosting.
  • NTC temperature sensor input for accurate measurements.
  • Digital input for passive switch quantity.
  • Bright 2-digit red LED display.
  • Durable ABS matte flame-retardant plastic shell.
  • Front panel protection level IP65.

2.2 Eleman

Pake pwodwi a tipikman gen ladan:

  • XR02CX-5N0C1 Temperature Controller unit
  • NTC Temperature Probe (optional, depending on SKU)
  • Klip aliye pou enstalasyon panèl
Copeland XR02CX-5N0C1 Temperature Controller with probe and mounting clips
Figure 1: Copeland XR02CX-5N0C1 Temperature Controller with included accessories.
Devan view of the Copeland XR02CX-5N0C1 Temperature Controller
Figi 2: Devan view of the controller showing the display and control buttons.

3. Espesifikasyon

Paramèt Valè
Modèl XR02CX-5N0C1
Mak Copeland (Dixell/Copeland)
Kalite Sòti Single output (compressor control, shutdown defrosting)
Opsyon ekipman pou pouvwa 12Vac/dc ± 10%, 24Vac/dc ± 10%, 230Vac ± 10%/50-60Hz, 110Vac ± 10%/50-60Hz (refer to nameplate)
Konsomasyon pouvwa Max 3VA
Ekspozisyon 2 red digital tubes, 14.2mm high
Antre 1 NTC input (temperature sensor), range -40 ℃ to 110 ℃
Antre dijital Passive switch quantity
Sòti Relay Compressor SPST A, 250Vac; 20 (8) A 250Vac (Max instantaneous 20A, rated 8A)
Shell Materyèl ABS matte flame-retardant plastic
Dimensions (Front) 32x74mm
Pwofondè 60mm
Installation Size (Panel Opening) 71x29mm
Protection Level (Overall) IP20
Protection Level (Front Panel) IP65
Batri enkli Non
Sèvi ak Anviwònman Andedan kay la
Sètifikasyon CE
Orijin Lachin tè pwensipal
Detaye view of the controller's label with specifications
Figure 3: Product label showing detailed specifications.

4. Enstalasyon

The XR02CX-5N0C1 controller is designed for panel mounting. Ensure all power is disconnected before proceeding with installation.

4.1 Panel Mounting

  1. Cut an opening of 71x29mm in the desired panel.
  2. Insert the controller into the opening from the front.
  3. Secure the controller using the provided mounting clips from the rear of the panel.
Dimensional drawing of the controller
Figure 4: Controller dimensions (Front: 32x74mm, Depth: 60mm).
Panel cutout dimensions for installation
Figure 5: Required panel cutout dimensions (71x29mm).

5. Dyagram fil elektrik

Refer to the diagram below for correct electrical connections. Ensure all wiring is done by a qualified professional and complies with local electrical codes. The power supply voltage must match the controller's specified voltage (e.g., 230V~ 50-60Hz for the 220V model).

Wiring diagram for the XR02CX controller
Figure 6: Wiring Diagram for XR02CX-5N0C1.

Koneksyon tèminal:

  • Tèminal 1-2: Hot Key connection.
  • Tèminal 3-4: Digital Input for external signals.
  • Tèminal 5-6: NTC Probe input (Room temperature sensor).
  • Tèminal 7-8: Power Supply (Line, e.g., 230V~ 50-60Hz).
  • Tèminal 8-9: Compressor Output (Comp).
Dèyè view of the controller showing wiring terminals and label
Figi 7: Dèyè view showing terminal block layout.

6. Operasyon

The controller features a simple interface for setting and monitoring temperature.

6.1 Kontwòl Panel Front

Front panel button functions
Figure 8: Front panel buttons and their functions.
  • SET bouton: Abitye view and modify the setpoint temperature and access programming parameters.
  • Bouton flèch moute: Increases the displayed value or navigates through parameters.
  • Bouton flèch desann: Decreases the displayed value or navigates through parameters.
  • Bouton AUX: Typically used for auxiliary functions or to initiate manual defrost cycles.
  • Ekspozisyon: Shows the current temperature or parameter values.

6.2 Setting the Temperature Setpoint

  1. Peze a SET button briefly to display the current setpoint.
  2. Peze epi kenbe la SET button for a few seconds until the setpoint value starts flashing.
  3. Sèvi ak la Up or Desann bouton flèch yo pou ajiste pwen konfigirasyon an nan tanperati ou vle a.
  4. Peze a SET Peze bouton an ankò pou konfime epi sove nouvo pwen konfigirasyon an.

6.3 Dekonjle

The controller supports shutdown defrosting. Consult the full programming manual (if available) for detailed defrost cycle settings. Manual defrost can typically be initiated by pressing and holding the AUX bouton.

7. Antretyen

Antretyen regilye asire lonjevite ak pèfòmans optimal kontwolè tanperati ou a.

7.1 Netwayaj

  • Netwaye panèl la devan ak yon mou, damp twal. Pa sèvi ak pwodui netwayaj abrazif oswa solvang.
  • Ensure no liquids enter the controller unit, especially around the buttons and display.

7.2 Probe Inspection

  • Periodically check the NTC temperature probe and its wiring for any signs of damage or corrosion.
  • Ensure the probe is securely placed in the area where temperature needs to be measured.

7.3 Koneksyon elektrik

  • Occasionally inspect all electrical connections to ensure they are tight and free from corrosion.
  • If any wiring appears damaged, replace it immediately.

NAN. Depanaj

Seksyon sa a bay solisyon pou pwoblèm komen ou ka rankontre.

Pwoblèm Kòz posib Solisyon
Kontwolè pa limen Pa gen ekipman pou kouran; vòltaj ki pa kòrèktage; fil elektrik ki lach. Check power source; verify voltage matches controller; inspect wiring connections.
Lekti tanperati ki pa kòrèk Faulty NTC probe; probe not correctly installed; wiring issue. Check probe connection; ensure probe is in correct location; replace probe if damaged.
Compressor not engaging/disengaging Setpoint issue; relay fault; wiring to compressor incorrect. Verify setpoint and differential settings; check compressor wiring; consult a technician if relay is suspected faulty.
Ekspozisyon montre kòd erè Sensor error; internal fault. Refer to the full programming manual for specific error code meanings. Check sensor connections.

9. Konsèy itilizatè yo

  • Always ensure the power supply is stable and within the specified voltage range to prevent damage to the controller.
  • For optimal temperature control, place the NTC probe in a location that accurately reflects the temperature of the controlled environment, away from direct airflow or heat sources.
  • Familiarize yourself with the programming parameters to fine-tune the controller's behavior for your specific application.
  • Nan ka pouvwa outages, most controllers retain their settings, but it's good practice to verify the setpoint once power is restored.

10. Garanti ak sipò

For warranty information and technical support, please refer to the documentation provided with your purchase or contact your supplier. Keep your purchase receipt as proof of purchase.

Dokiman ki gen rapò - XR02CX-5N0C1

Preview Enstriksyon pou Chanje Inite Mezi Universal-XR
Yon gid konplè pou kontwolè ki baze sou mikwo-procesè Copeland Universal-XR la, ki kouvri enstalasyon, demaraj rapid, konfigirasyon paramèt, fonksyon bouton, alam, depanaj, ak espesifikasyon teknik pou aplikasyon refrijerasyon.
Preview Copeland FULL TOUCH XH78T Quick Start Guide
This document provides a quick start guide for the Copeland FULL TOUCH XH78T digital temperature controller, detailing its features, user interface, technical specifications, and safety information.
Preview Kontwolè Copeland UNIVERSAL-BLE: Koneksyon Bluetooth pou Refrijerasyon ak Chofaj
Dekouvri kontwolè Copeland UNIVERSAL-BLE yo, ki gen koneksyon Bluetooth pou kontwòl an tan reyèl ak mizajou a distans atravè yon aplikasyon dedye. Ideyal pou aplikasyon refrijerasyon ak chofaj, kontwolè versatile sa yo ranplase modèl estanda yo fasilman. Gen ladan espesifikasyon teknik, karakteristik, ak kòd ki disponib yo.
Preview Gid Enstalasyon Kontwolè Tanperati Chanm Fwad Copeland XER
Gid enstalasyon konplè pou Kontwolè Tanperati Chanm Fwad Copeland XER a, ki kouvri koòdone itilizatè a, règleman an, operasyon degivraj la, fil elektrik yo, ak espesifikasyon teknik yo.
Preview XM600 Case Controllers Firmware v5.4j Release Notes - XM670K, XM678D, XM679K
Release notes for Copeland's XM600 Case Controllers (XM670K, XM678D, XM679K) firmware update v5.4j. Details key enhancements, additional notes, and firmware update instructions.
Preview Copeland XM700 Controllers and CT760 Keyboard: Refrigerated Case Management
Comprehensive souview of Copeland's XM700 electronic regulators and CT760 keyboard for managing multiplexed refrigerated cases. Features include Bluetooth connectivity, dedicated APP, energy saving algorithms, natural refrigerant compatibility, and technical specifications.