1. Pwodwi souview
The KONLEN WIFI intelligent water level controller is designed for precise water level monitoring and control. It integrates with the Tuya Smart or Smart Life App, allowing users to manage water supplement or drainage, receive high and low water level alarm notifications, and review historical data. This versatile controller is suitable for various applications including HVAC systems, hot water processes, municipal drainage, boilers, water towers, storage tanks, and irrigation systems.
The controller features both LED indicators and an App interface to display six distinct water levels: 0%, 20%, 40%, 60%, 80%, and 100%.
Video: Demonstration of the KONLEN Smart Water Level Controller in action, showing water level changes and app interaction.
2. Pake kontni
Version 1: AC90V to 250V
- 1 x manyèl itilizatè angle
- 1 x WIFI Water Level Controller
- 6 x Water Level Probes
Version 2: DC5V
- 1 x manyèl itilizatè angle
- 1 x WIFI Water Level Controller
- 6 x Water Level Probes
- 1 x DC5V Power Adapter (EU/US/UK/AU plug, appropriate for your country)
Nòt: Users can extend the probe cables if needed. The maximum recommended extension length is 50 to 80 meters (approximately 200ft to 260ft).

Image: Front, side, and back views of the controller with dimensions, alongside the six water level probes.
3. Controller Layout and Terminals
The controller features several buttons, indicators, and terminals for operation and connection.
3.1 Karakteristik Front Panel
- A: WIFI Configuration Button / Manual Switch for Relay Output 1
- B: Manual Switch for Relay Output 2 (Effective only when the current water level is between the preset start and stop levels.)
- C: WIFI Configuration Indicator / Relay Output 1 Status Indicator
- D: Relay Output 2 Status Indicator
- E: Current Water Level Display (LED bar graph)
- F: Built-in Buzzer (For high/low water level local alarms.)
3.2 Koneksyon Tèminal
The controller has terminals for water level probes, relay outputs, and power input.
- Tèminal 1: 100% Water Level Probe Connection
- Tèminal 2: 80% Water Level Probe Connection
- Tèminal 3: 60% Water Level Probe Connection
- Tèminal 4: 40% Water Level Probe Connection
- Tèminal 5: 20% Water Level Probe Connection
- Tèminal 6: 0% Water Level Probe Connection (Common Terminal - COM)
- Tèminal 7, 8: Relay Output 1 (Normal Open)
- Tèminal 9, 10: Relay Output 2 (Normal Open)
- Tèminal 11, 12: Working Power Input (AC90V-250V for Version 1, DC5V for Version 2)

Imaj: Detaye view of the controller's front panel with labeled buttons, indicators, and terminal connections.
4. Enstalasyon ak fil elektrik
Proper wiring is crucial for the safe and correct operation of the water level controller. Ensure all power is disconnected before performing any wiring.
Nòt: The relay outputs (CH1/CH2) function like a common power switch and provide no voltage output. Wiring connections are similar to those for a normal switch.
4.1 Dyagram Fil Jeneral

Image: General wiring diagram showing the controller connected to a water tank with six probes, a pump/valve for adding water (Relay 1), and a pump/valve for draining water (Relay 2), along with the power supply.
4.2 Fil elektrik Egzample 1: Adding Water with Heater Protection
This setup uses Relay CH1 to control a water pump for adding water and Relay CH2 to control a heater for anti-dry boiling protection.
- Relay CH1 (Water Pump - Add Water): Starts adding water when the level is <20% (0% display) and stops when it reaches 100%.
- Relay CH2 (Heater - Anti-Dry Boiling Protection): Turns on the heater when the water level is ≥25% and turns it off if the level drops below 20% to prevent dry boiling.

Image: Wiring diagram illustrating the connection for adding water using Relay 1 and heater protection using Relay 2. Relay 1 is connected to a pump/valve for water inlet, and Relay 2 is connected to a heater.
4.3 Fil elektrik Egzample 2: Draining Water with Siren Alarm
This setup uses Relay CH1 to control a water pump for draining water and Relay CH2 to activate a siren or flash light for high/low water level alarms.
- Relay CH1 (Water Pump - Drain Water): Starts draining water when the level reaches 100% and stops when it is ≤20%.
- Relay CH2 (Siren/Flash Light - Alarm): Activates the alarm if the water level is ≤20% (low level alarm) or ≥80% (high level alarm).

Image: Wiring diagram illustrating the connection for draining water using Relay 1 and a siren alarm using Relay 2. Relay 1 is connected to a pump/valve for water drainage, and Relay 2 is connected to a siren.
4.4 Fil elektrik Egzample 3: Adding Water (CH1) and Draining Water (CH2)
This configuration is suitable for applications requiring both water addition and drainage, such as public baths.
- Relay CH1 (First Water Pump - Add Water): Controls the addition of water.
- Relay CH2 (Second Water Pump - Drain Water): Controls the drainage of water.

Image: Wiring diagram showing Relay 1 connected to a pump/valve for water inlet and Relay 2 connected to a pump/valve for water drainage, allowing for both adding and draining functions.
5. App Operation and Settings
The KONLEN Smart Water Level Controller is managed via the Tuya Smart or Smart Life App. The app provides real-time water level display, control over relay outputs, and alarm settings.

Image: Screenshot of the KONLEN Liquid Level Controller app interface, highlighting various controls and indicators such as Switch 1 (Relay CH1), Switch 2 (Relay CH2), Work Mode, CH2 Function, Level settings, Alarms, Limited Time, Ch1 Delay, Sensor Status, and Main Switch.
5.1 Water Level Display
The App displays the current water level in real-time, mirroring the LED indicators on the controller. The display stages are 0%, 20%, 40%, 60%, 80%, and 100%.
5.2 Relay CH1 Control Modes (Water Pump)
Relay CH1 is typically connected to a water pump for controlling water addition or drainage. The following work modes can be configured in the App:
- Add Water Mode:
When water level ≤ 'Level On1' (start-up level), Relay 1 connects to start adding water.
When water level ≥ 'Level Off1' (stop level), Relay 1 disconnects to stop adding water.
Image: App screenshot showing the settings for 'Add' work mode, with 'Level On1' set to 20% and 'Level Off1' set to 100%.
- Drain Water Mode:
When water level ≥ 'Level On1' (start-up level), Relay 1 connects to start draining water.
When water level ≤ 'Level Off1' (stop level), Relay 1 disconnects to stop draining water.
Image: App screenshot showing the settings for 'Drain' work mode, with 'Level On1' set to 100% and 'Level Off1' set to 0%.
- Time-Limited Adding Water Mode:
When water level ≤ 'Level On1' (start-up level), Relay 1 connects and a timer starts. Relay 1 will automatically disconnect after the 'Limited Time' (set in minutes) has elapsed, stopping water addition.
Image: App screenshot showing the settings for 'Add_limited' work mode, with 'Limited Time' set to 60 minutes.
- Time-Limited Draining Water Mode:
When water level ≥ 'Level On1' (start-up level), Relay 1 connects and a timer starts. Relay 1 will automatically disconnect after the 'Limited Time' (set in minutes) has elapsed, stopping water drainage.
Image: App screenshot showing the settings for 'Drain_limited' work mode, with 'Limited Time' set to 120 minutes.
A 'Ch1 Delay' setting (0 to 300 seconds) is also available for Relay CH1.
5.3 Relay CH2 Function Options
Relay CH2 offers supplementary functions and can be configured with the following options:
- Manyèl: Allows manual control of Relay CH2.
- Alam: Connect a siren or flash light for local high/low water level alarms.
- L_On, H_Off (Low Level On, High Level Off): Relay CH2 turns on when the water level is low and turns off when it's high.
- L_Off, H_On (Low Level Off, High Level On): Relay CH2 turns off when the water level is low and turns on when it's high.
These options allow CH2 to control a second water pump for adding/draining or to connect a heater for anti-dry boiling protection.
5.4 High & Low Water Level Alert Settings
The controller supports flexible high and low water level alerts:
- Alam Remote: App push notifications for high and/or low water levels.
- Alam Buzzer: Activates the built-in buzzer (F) for local alerts.
- External Siren: If Relay CH2 is set to 'Alarm' mode and connected to a siren, it will activate for local alerts.
You can choose to enable alarms for only high water level, only low water level, or both. The specific low and high alarm levels can be set in the App (e.g., Low Level Alarm: 20%, High Level Alarm: 80%).

Image: App screenshot showing a 'High Alarm' notification, indicating the water level is above the upper limit.

Image: App screenshot showing a 'Low Alarm' notification, indicating the water level is below the lower limit.
5.5 Main Switch (Emergency Setting)
The 'Main Switch' (No.17 in the App interface) is an emergency setting. If a water pump or water probe malfunctions, you can set this switch to 'Off' to temporarily disable both relays. The water level display will continue to function normally, allowing for monitoring even when control is paused.
6. Antretyen
To ensure optimal performance and longevity of your KONLEN Smart Water Level Controller, follow these maintenance guidelines:
- Netwayaj regilye: Periodically inspect and clean the water level probes to prevent mineral buildup or debris from affecting their accuracy.
- Enspeksyon fil elektrik: Routinely check all wiring connections for any signs of wear, corrosion, or loose terminals. Ensure connections are secure.
- Mizajou lojisyèl: Keep the Tuya Smart or Smart Life App updated to the latest version to benefit from new features, improvements, and security patches.
- Kondisyon anviwònman: Ensure the controller is operated within its specified working environment temperature range (-10℃ to 50℃) and protected from excessive moisture or direct sunlight.
- Pwovizyon pou pouvwa: Verify that the power supply to the controller is stable and within the specified voltage range (AC90V-250V or DC5V, depending on your version).
NAN. Depanaj
If you encounter issues with your water level controller, refer to the following common troubleshooting steps:
- Controller Not Responding/No Power:
Check the power supply connection to terminals 11 and 12. Ensure the correct voltage version (AC or DC) is used.
Verifye ke priz kouran an fonksyone. - Incorrect Water Level Readings:
Inspect the water level probes for any dirt, scale, or damage. Clean them if necessary.
Ensure all probe connections to terminals 1-6 are secure and correctly wired.
Check if the 'Sensor Status' in the App shows 'OK'. - Pump/Valve Not Activating/Deactivating:
Verify the wiring of the pump/valve to Relay Output 1 (terminals 7,8) or Relay Output 2 (terminals 9,10). Remember these are dry contacts (no voltage pwodiksyon).
Check the App settings for the respective relay (CH1 or CH2) to ensure the 'Work Mode' and 'Level On/Off' thresholds are correctly configured.
Ensure the 'Main Switch' (No.17 in App) is set to 'On'.
If controlling large loads (over 2000W resistive or 500W inductive), confirm an AC contactor is installed as recommended. - Pa gen Notifikasyon Aplikasyon/Kontwòl Adistans:
Ensure the controller is connected to your 2.4GHz Wi-Fi network (5GHz networks are not supported).
Check your smartphone's internet connection and App notification settings.
Verify that the 'Remote Alarm' setting in the App is enabled for high and/or low water levels. - Buzzer/Siren Not Sounding:
If using the built-in buzzer, ensure 'Buzzer Alarm' is enabled in the App.
If using an external siren, verify its connection to Relay CH2 and that CH2's function is set to 'Alarm'.
If the issue persists after following these steps, contact customer support for further assistance.
8. Espesifikasyon
| Karakteristik | Spesifikasyon |
|---|---|
| Dimansyon pwodwi | 89mm x 55mm x 44mm |
| Kontwolè Power Supply | Version 1: AC90V-250V Version 2: DC5V |
| Konsomasyon pouvwa | Mwens pase 2W |
| Relè Sòti | Two (Normal Open) |
| Relè Kapasite Kontakte | 10A (Chaj reziste) 2A (Inductive Load) Max 2000W (Resistive Load) Max 500W (Motor/Water Pump) (For larger loads, an AC contactor is required) |
| Relay CH1 Limited Running Time | 0 to 720 minutes (App settable) |
| Relay CH1 Time Delay Setting | 0 to 300 seconds (App settable) |
| Relay Lifespan | 100,000 fwa |
| Tanperati anviwònman k ap travay | -10 ℃ pou 50 ℃ |
| Koneksyon Wi-Fi | Wi-Fi 2.4GHz B/G/N (5GHz not supported) |
| Sond Nivo Dlo | 6 probes included |
| Probe Cable Extension | Max 50-80 meters (approx. 200-260ft) |
9. Konsèy itilizatè yo
- Montaj DIN Rail: The controller is designed with a DIN rail attachment at the back for easy and secure installation in electrical enclosures.
- Ekstansyon Kab: If the provided probe cables are not long enough for your application, they can be extended. Ensure to use appropriate gauge wiring for extensions, up to a maximum of 80 meters (260 feet).
- Jesyon chaj: For applications involving motors or pumps exceeding 500W, or resistive loads over 2000W, it is essential to use an external AC contactor to prevent damage to the controller's relays.
10. Garanti ak sipò
Pou enfòmasyon sou garanti a, sipò teknik, oswa kesyon sou sèvis, tanpri al gade enfòmasyon kontak yo te bay nan men détaillant ou a oswa nan men reprezantan ofisyèl manifakti a. websit la. Kenbe resi acha ou kòm prèv acha.