SINOTIMER TM929AK

Sinotimer Digital Analogue DIN Module Time Switch Instruction Manual

Models: TM929AKL (16A), TM929BKL (30A)

1. Entwodiksyon

This manual provides detailed instructions for the installation, operation, and maintenance of your Sinotimer Digital Analogue DIN Module Time Switch. This device is designed for industrial applications, offering precise 24-hour programmable timing with a large LCD display and backlight functionality.

2. Fonksyon pwodwi

  • Clock display (24-hour format).
  • Programmable Timer with up to 96 ON/OFF programs per day.
  • Backlight feature: The backlight illuminates when the timer is off and automatically disappears after 5 seconds.

3. Espesifikasyon

ParamètValè
Nimewo ModèlTM929AKL (16A), TM929BKL (30A)
Pwovizyon pou pouvwa85 ~ 265VAC, 50/60Hz
Max. Current of Output Load16A / 30A (selon modèl la)
Pwogram yoJiska 96 ON/OFF pa jou
Anviwònman Range15 minit a 24 èdtan
Minimum Setting Interval15 minit
EkspozisyonLCD ak ekleraj
Dimansyon86.5mm x 36mm x 68.5mm
Enstalasyon35mm DIN Rail
BatriTM929AKL (16A): Replaceable CR2032; TM929BKL (30A): Non-replaceable internal battery
Konsomasyon pouvwa<5VA
Black-out (Power Reserve)90 jou
SètifikasyonCE

Nòt: The TM929AKL (16A) model features a replaceable CR2032 battery, while the TM929BKL (30A) model has a non-replaceable internal battery. Wiring diagrams differ between models.

Dimensions of the Sinotimer DIN module time switch, showing height 8.7cm, width 3.5cm, and depth 6.5cm with a 4.7cm front panel depth.
Figi 1: Dimansyon pwodwi a

4. Enstalasyon

4.1 Enstalasyon

The time switch is designed for mounting on a standard 35mm DIN rail. Ensure the mounting location is dry, well-ventilated, and free from excessive vibrations or extreme temperatures.

Retounen view of the Sinotimer time switch showing the DIN rail mounting clip.
Figure 2: DIN Rail Mounting Mechanism

4.2 fil elektrik

AVÈTISMAN: All wiring should be performed by a qualified electrician and in accordance with local electrical codes. Ensure power is disconnected before attempting any wiring.

The timer has terminals for Line (L), Neutral (N), and output contacts (NO, NC, Common). Refer to the diagrams below for typical wiring configurations.

Wiring diagram for direct connection of a light bulb to the Sinotimer time switch. Line (L) and Neutral (N) are connected to terminals 1 and 2. The load (light bulb) is connected between terminal 3 (NO) and Neutral (N).
Figure 3: Direct Wiring Diagram (e.g., for a light bulb)
Wiring diagram for connecting the Sinotimer time switch with an external contactor to control a higher load. Line (L) and Neutral (N) are connected to terminals 1 and 2. The timer's NO contact (terminals 3 and 5) controls the coil of an external contactor (e.g., ABB AX-09-30-10). The load is then connected through the contactor's power contacts.
Figure 4: Wiring Diagram with Contactor (for higher loads)

4.3 Premye Limen

Once wired correctly, apply power to the device. The LCD will illuminate and display the current time. If the display is blank, check the power supply and, for the 16A model, ensure the CR2032 battery is correctly installed.

5. Operasyon Enstriksyon

The timer features a MENU button, UP/DOWN arrow buttons, an OK button, and a Reset (Res) button.

Close-up of the Sinotimer time switch's control panel, showing the MENU, UP, DOWN, OK, and Reset buttons, along with the LCD display.
Figi 5: Panèl kontwòl laview

5.1 Mete Lè Aktyèl la

  1. Press the 'MENU' button.
  2. Use the 'UP' and 'DOWN' arrow buttons to adjust the hour and minute.
  3. Press 'OK' to confirm each setting.
  4. Press 'MENU' again to return to the clock display.

5.2 Pwogramasyon Sik ON/OFF

The timer supports up to 96 ON/OFF programs. Each program can be set for specific days of the week.

  1. Press the 'MENU' button to enter programming mode. The display will show '00:00' or a program number.
  2. Use 'UP' and 'DOWN' to set the desired ON time (hour and minute). Press 'OK' to confirm.
  3. Next, set the desired OFF time (hour and minute). Press 'OK' to confirm.
  4. Use 'UP' and 'DOWN' to select the days of the week for this program (e.g., Mon-Fri, Sat-Sun, or individual days). Press 'OK' to confirm.
  5. Repeat steps 2-4 for additional programs.
  6. Press 'MENU' to exit programming mode and save settings.

5.3 Manyèl Override

To manually switch the timer's output, press the 'OK' button. This will cycle through the modes: ON (always on), AUTO (follows programmed schedule), and OFF (always off).

Video 1: Demonstrating manual override and setting intervals. Press 'OK' to switch working mode (ON/AUTO/OFF). Press 'MENU' to set intervals, then 'OK' to confirm, and 'MENU' to return to clock status.

6. Antretyen

6.1 Battery Replacement (TM929AKL 16A only)

The TM929AKL (16A) model uses a replaceable CR2032 battery. If the display becomes dim or the time settings are lost frequently during power outages, the battery may need replacement. Carefully open the battery compartment and replace the CR2032 battery, ensuring correct polarity. The TM929BKL (30A) model has a non-replaceable internal battery.

6.2 Swen Jeneral

Keep the device clean and dry. Use a soft, dry cloth for cleaning. Avoid using abrasive cleaners or solvents. Ensure the protective cover is closed to prevent dust and moisture ingress.

NAN. Depanaj

  • Ekspozisyon an vid: Check the main power supply. For the 16A model, check the CR2032 battery.
  • Timer not switching: Verify wiring connections are secure and correct. Ensure the timer is in 'AUTO' mode. Check that programs are set correctly and not conflicting.
  • Lè ki pa kòrèk: Reset the timer using the 'Res' button and reprogram the current time.
  • Programs not executing: Ensure the timer is in 'AUTO' mode. Check that the ON/OFF times and days are correctly set.

7.1 Reyajiste revèy la

To perform a full reset, press the 'Res' button (usually a small recessed button requiring a pointed object like a pen tip). This will clear all settings and return the timer to its factory default state. You will need to reprogram the current time and all desired ON/OFF cycles.

8. Konsèy itilizatè yo

  • For precise control, utilize the full capacity of 96 ON/OFF programs to manage complex schedules.
  • When setting intervals, remember the minimum programmable interval is 15 minutes.
  • Always double-check your wiring before applying power to prevent damage to the unit or connected appliances.

9. Garanti ak sipò

For technical assistance, warranty claims, or further information, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.