Manyèl ak Gid Itilizatè SONBUS
SONBUS (Shanghai Sonbest Industrial Co., Ltd) se yon manifakti pwofesyonèl detèktè ak enstriman, ki espesyalize nan automatisation agrikòl, siveyans endistriyèl, ak sistèm kontwòl anviwònman.
About SONBUS manuals on Manuals.plus
SONBUS (Shanghai Sonbest Industrial Co., Ltd) is a leading manufacturer of professional sensing equipment and industrial instruments. Operating brands such as SONBEST, KLHA, ak TRANBALL, the company specializes in solutions for agricultural automation and intelligent industrial control.
The SONBUS product line includes high-precision sensors for measuring temperature, humidity, soil conductivity, soil moisture, and various gas concentrations. Designed for system integrators, these devices typically support standard protocols like RS485 MODBUS-RTU, 4-20mA, and 0-5V/10V analog outputs, ensuring seamless compatibility with PLCs, DCS, and other monitoring systems.
Manyèl SONBUS yo
Dènye manyèl yo soti nan manuals+ òganize pou mak sa a.
SONBEST SM1398 High Temperature Duct Wind Speed Sensor User Manual
Manyèl Itilizatè Capteur Imidite Tanperati Segondè SONBEST SM3713B
SONBEST RS485 Deyò Segondè Sansiblite Nerjaveèi Iluminasyon Capteur Manyèl Itilizatè
SONBEST SM7005 Metal Eksteryè Shell Optical Lapli Sensor Manyèl Itilizatè
SONBEST SM2130-CH20 entèfas fòmaldeyid tèsteur manyèl itilizatè
SONBEST SC7237B Entèfas ki ap dirije Display Manyèl Itilizatè Kontwolè Presyon Diferans
SONBEST SY8206 Post Kalite Enfrawouj Tanperati Deteksyon Detektè Manyèl Itilizatè
SONBEST SZ2801 ZIGBEE Wireless Soil Midite Capteur Manyèl Itilizatè
SONBEST SM7901V Carrier Plate Probe bri modil manyèl itilizatè
SONBUS support FAQ
Kesyon komen sou manyèl, anrejistreman, ak sipò pou mak sa a.
-
What communication protocols do SONBUS sensors typically use?
Most SONBUS sensors utilize the standard RS485 MODBUS-RTU protocol. Some models also offer analog outputs (4-20mA, 0-5V, 0-10V) or wireless options like LoRa, Zigbee, and WiFi.
-
How do I change the device address on a SONBUS RS485 sensor?
You can change the device address by writing to the specific register (often register 0x66) using the RS485 Modbus write command (function code 0x06). Refer to the specific product manual for the exact register map and command structure.
-
What is the default baud rate for SONBUS Modbus devices?
The default baud rate is typically 9600 bps with 8 data bits, no parity, and 1 stop bit (9600, 8, N, 1). This can usually be modified via software commands.
-
Where can I find the software to configure SONBUS sensors?
Configuration usually requires a standard serial port debugging tool or Modbus poll software connected via a USB-to-RS485 converter. SONBUS may also provide specific utility software for their devices on their official websit.