Aninerel 3.6kW Hybrid Solar Inverter (48V DC to 110V AC) Instruction Manual
Model: ANJ-3600W-LVP
1. Entwodiksyon
This manual provides essential information for the safe and efficient operation of your Aninerel 3.6kW Hybrid Solar Inverter. Please read this manual thoroughly before installation and use, and retain it for future reference. This inverter is designed to convert 48V DC power to 110V AC pure sine wave power, suitable for various on-grid and off-grid applications.
Imaj 1: Plis paseview of the Aninerel 3.6kW Hybrid Solar Inverter, showcasing its main features including battery compatibility, grid connection, power scaling, versatile design, flexible settings, and wireless communication.
2. Enstriksyon Sekirite
Toujou obsève prekosyon sekirite sa yo pou diminye risk chòk elektrik, dife, oswa blesi:
Pèsonèl ki kalifye: Se sèlman pèsonèl kalifye ki ta dwe fè enstalasyon ak antretyen.
Itilizasyon andedan kay la: This product is designed for indoor use. It is forbidden to use it outdoors.
Vantilasyon: Ensure adequate ventilation around the inverter. Maintain at least 8 inches of clear space on all sides for proper airflow.
Koneksyon batri: Always connect the battery to the inverter first before connecting solar panels or AC input.
Atè: Ensure the inverter is properly grounded to prevent electrical hazards.
Are ijans: Familiarize yourself with the emergency shutdown procedures.
Pwoteksyon Surcharge: The inverter includes built-in protections against overvoltage, undervoltage, reverse polarity, and short circuits.
Image 2: A warning label emphasizing that the inverter is an indoor product and should not be used outdoors.
3. Karakteristik kle
3600W Hybrid Solar Inverter: Converts DC 48V to pure sine wave AC 110V, delivering 3,600W continuous and 7,200W peak output. Supports up to 4,500W PV input with 80A MPPT solar charging, maximum DC voltage 300V. Features 40A max AC input, 50/60Hz output frequency, starting voltage above 125VDC, and 80A maximum PV charging current.
Built-in 80A MPPT Solar Charging Controller: Maximizes solar energy harvesting, boosting charging efficiency by up to 30%. Compatible with high-voltage PV arrays (up to 300VDC).
Sipò paralèl: Supports parallel connection of up to 6 units for increased power (up to 21.6KW). Offers 120V single-phase, 120V/240V split-phase, and 208V three-phase output configurations.
Smart LCD Screen with Real-Time Monitoring: Responsive LCD screen and indicator LEDs for real-time monitoring of power input/output, battery status, and system alerts. Intuitive control buttons for system settings.
Flexible Charging & Output Modes: Four charging modes (Solar Only, AC Priority, Solar Priority, Hybrid Charging) and three output modes (Mains Priority, PV Priority, Inverter Output).
48V Battery & No-Battery Operation: Compatible with AGM, GEL, Lead-acid, Li-ion, and LiFePO4 48V batteries. Supports no-battery mode for direct solar-to-load applications.
Rugged IP65 Dustproof & Durable Design: Built to withstand harsh environments with IP65-rated enclosure for indoor or semi-outdoor use. Features smart cooling with a variable speed fan.
Aplikasyon lajè: Suitable for RVs, camping boats, home emergency situations, powering various appliances.
Image 3: Visual representation of the inverter's versatile design, showing single-phase, split-phase, and three-phase parallel connection options for up to six units.
4. Enstalasyon ak Enstalasyon
4.1 Debalaj ak enspeksyon
Carefully unpack the inverter and all accessories. Inspect for any damage during transit. The package should include the inverter, instruction manual, installation toolkit, current sharing detection line, parallel cable, anti-reverse current CT, and WiFi module.
Image 4: Contents of the product package, including the inverter, manual, installation toolkit, various cables, and a WiFi module.
4.2 Idantifikasyon konpozan
Familiarize yourself with the inverter's external components and connection points:
Limyè endikatè
Ekran LCD
Manyen kle
Pwotektè Surcharge
Tè vis kenbe
AC pwodiksyon pò
Pò WiFi (opsyonèl)
AC opinyon pò
Pò kominikasyon RS485-2
Pò kominikasyon RS485-1
USB pò kominikasyon
Refwadisman fanatik
ON/OFF switch baskil
Pò kontak sèk
Pò pataje aktyèl (modil paralèl sèlman)
Pò kominikasyon paralèl (modil paralèl sèlman)
Pò batri
pò PV
Image 5: Detailed diagram identifying all external ports and features of the inverter.
4.3 Koneksyon fil elektrik
Follow these steps for safe and correct wiring:
Koneksyon batri: Connect the 48V battery to the designated battery ports (BAT+ and BAT-). Ensure correct polarity.
Antre PV: Connect your solar panel array to the PV ports (PV+ and PV-). Ensure the PV voltage is within the specified range (90-260Vdc MPPT range, max 300Vdc open circuit).
Antre/Sòti AC: Connect AC input from the grid or generator to the AC IN ports. Connect your loads to the AC OUT ports.
Atè: Connect the grounding wire to the grounding screw hold.
Image 6: A comprehensive wiring diagram showing connections for PV input, utility/generator input, battery, and inverter output.
Gwosè Fil Rekòmande:
Koneksyon
Recommended Wire Diameter
Max Kouran
AC Antre
10mm²/7AWG
40A
Batri Antre
25mm²/3AWG
120A (Charge) / 85A (Discharge)
AC Sòti
10mm²/7AWG
30A (Inverter) / 40A (Bypass)
4.4 Parallel Installation (Optional)
For increased power, up to 6 units can be connected in parallel. Refer to the detailed wiring diagrams for single-phase, split-phase, and three-phase configurations in the full manual. Ensure all units are properly synchronized.
Image 7: Detailed illustration of single-phase, split-phase, and three-phase parallel connection setups for multiple inverters.
5. Operasyon
5.1 Limen/Etenyen
After all connections are secure, turn on the battery. Then, use the ON/OFF rocker switch on the inverter to power it on. The LCD screen will illuminate, displaying system status. To power off, reverse the process: turn off the inverter first, then disconnect the battery.
5.2 Ekran LCD ak Paramèt
The LCD screen provides real-time data and allows configuration of various parameters. Use the control buttons (SET, UP, DOWN, ENTER) to navigate menus and adjust settings.
Priyorite chaj: Control how the battery bank is charged from different power sources (Solar Priority, Solar and AC input, Solar Only).
Priyorite Chaj: Control how appliances are powered to prevent power interruptions (Solar Priority, AC Priority, DC Priority).
Image 8: The inverter's LCD screen showing options for Charging Priority and Load Priority settings.
5.3 Siveyans Wi-Fi
The inverter is equipped with a Wi-Fi module for real-time monitoring via a mobile application. Chèche pou "Smart Value" in your app store to download and install the application. This allows remote monitoring of the inverter's operating status.
Image 9: Illustration of the Wi-Fi module connection and the availability of the "Smart Value" mobile application for real-time monitoring.
6. Antretyen
Netwayaj regilye: Keep the inverter clean and free from dust. Ensure ventilation openings are not blocked.
Tcheke Koneksyon: Tcheke tout koneksyon elektrik yo detanzantan pou wè si yo sere epi si gen siy korozyon.
Sante batri: Monitor battery status via the LCD or mobile app. Ensure batteries are maintained according to their manufacturer's guidelines.
Mizajou mikrolojisyèl: Tcheke pou dènye nouvèl firmwèr ki disponib yo pou asire pèfòmans optimal ak aksè a nouvo fonksyonalite yo.
NAN. Depanaj
This section provides solutions to common issues. For more complex problems, contact customer support.
Pa gen pwodiksyon pouvwa: Check battery connections, PV input, and AC input. Ensure the inverter is powered on and not in fault mode.
Endikatè Fay la Limen: Refer to the LCD display for specific fault codes and consult the detailed troubleshooting section in the full manual.
Batri pa chaje: Verify PV panel connections and sunlight availability. Check charging mode settings.
Pwoteksyon Surcharge: If an overload occurs, the inverter will shut down. Reduce the load and restart the inverter.
Video 1: This video demonstrates how to communicate with the battery and computer for the 5000W Solar Inverter. While the model differs slightly, the communication principles for battery and computer interaction are similar and can aid in troubleshooting.
8. Espesifikasyon
Aninerel ANJ-3600W-LVP Hybrid Solar Inverter
Rated Sòti pouvwa
3600VA/3600W
Max. Pik pouvwa
7200VA
Rated Sòti Voltage
120Vac ± 5%
Kapasite chaj nan motè
2HP
Rated AC Frekans
50Hz/60Hz
Kapasite paralèl
1 ~ 6
Sòti Voltage Waveform
Vag sinis pi bon kalite
Pwoteksyon Surcharge
(102%~load<125%)±10%: report error, turn off the output after 5 minutes; (125%~load<150%)±10%: report error, turn off the output after 10 seconds; load>=150%±10%: report error, turn off the output after 5 seconds;
Kalite batri
Lithium/Lead-acid batteries
Rated Battery Voltage
48V (Min. start voltage 44V)
Mains/Generator Input Range
(90Vac ~ 140Vac) ± 2%
Max. MPPT chaje aktyèl
80A
Max. Mains/Generator Charging Current
80A
Max. Hybrid Charging Current
80A
Num. of MPPT Trackers
1
Max. PV etalaj pouvwa
4000W
Max. Antre aktyèl
22A
Maks. Voltage nan Open Circuit
300Vdc
MPPT Voltage Range
90-260Vdc
Bypass Surcharge Kouran
40A
MPPT Tracking Efikasite
95%
Support Communication
WiFi Modules/RS485/CAN/USB/Dry contact
Dimansyon
16 * 11 * 4 pous
Pwa
7.8KG/17.2LB
Image 10: A table summarizing the technical specifications of the inverter, including power ratings, voltage, current, and communication features.
9. Garanti & Sipò
For warranty information and technical support, please refer to the official Aninerel websit la oubyen kontakte konsesyonè otorize ou a. Kenbe resi acha ou kòm prèv acha.
Plan pwoteksyon disponib pou pwoteksyon pwolonje:
Plan Pwoteksyon 2 Zan
Plan Pwoteksyon 3 Zan
Pwoteksyon Konplè: Yon sèl plan kouvri tout acha pase ak acha nan lavni ki kalifye yo.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.