1. Entwodiksyon
This manual provides essential instructions for the installation, operation, and maintenance of your Aninerel 3000W Hybrid Solar Inverter, model ANJ-3KW-LV-WIFI. This device is designed to convert 24V DC power to 110V AC pure sine wave power, suitable for various off-grid and backup power applications. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.

Figi 1.1: Devan view of the Aninerel 3000W Hybrid Solar Inverter. The inverter features a blue casing with the Aninerel logo and a central LCD display panel with control buttons.
2. Enstriksyon Sekirite
Toujou obsève prekosyon sekirite sa yo pou diminye risk chòk elektrik, dife, oswa blesi:
- Read all instructions and cautionary markings on the unit and in this manual before installation or operation.
- Do not disassemble the inverter. Refer servicing to qualified personnel. Incorrect reassembly may result in electric shock or fire.
- Pou diminye risk chòk elektrik, dekonekte tout fil elektrik anvan ou eseye nenpòt antretyen oswa netwayaj.
- This inverter is designed for indoor or semi-outdoor use with an IP65 rating. Avoid direct exposure to rain or snow.
- Ensure proper ventilation around the inverter to prevent overheating. Do not block ventilation openings.
- Sèvi ak zouti ki apwopriye yo ak ekipman pwoteksyon pèsonèl pandan enstalasyon an.
- Ensure all wiring connections are tight and secure to prevent loose connections that can cause overheating.
- Do not connect the inverter to a public utility grid without proper authorization and safety measures.
3. Pwodwi souview
The Aninerel 3000W Hybrid Solar Inverter integrates a pure sine wave inverter, an MPPT solar charge controller, and a battery charger into one compact unit. It is designed to provide uninterrupted power support.
3.1 Karakteristik kle
- 3000W Pure Sine Wave Output: Converts 24V DC to 110V AC, providing stable power for sensitive electronics.
- Kontwolè chaj solè MPPT 100A entegre: Maximizes solar energy harvesting with up to 500VDC PV input.
- Flexible Charging and Output Modes: Offers multiple modes (Solar Only, AC Priority, Hybrid Charging; Mains Priority, PV Priority, Hybrid Output) for diverse power management.
- Konpatibilite pil laj: Supports AGM, GEL, Lead-acid, Li-ion, and LiFePO4 24V batteries.
- Ekspozisyon LCD entelijan: Provides real-time monitoring and allows for easy configuration of system settings.
- Wi-Fi entegre: Enables remote monitoring of the inverter status (registration required).
- Konsepsyon solid: IP65-rated enclosure for durability in various environments, with intelligent cooling.
- Pwoteksyon konplè: Gen ladann overvoltage, undervoltage, reverse polarity, and short circuit protection.

Figi 3.1: Panèl Devan ak Dèyè Anlèview. This diagram labels the LCD display, indicators, function buttons, RS485 communication port, grounding terminal, battery input, dry contact port, built-in Wi-Fi, AC input, AC output, PV input, and power on/off switch.
3.2 Panèl Devan ak Endikatè
- Ekspozisyon LCD: Shows system status, operational data, and configuration settings.
- Endikatè chaje: Illuminates to indicate battery charging status.
- Endikatè estati: Provides general operational status of the inverter.
- Endikatè fay: Lights up to signal system errors or warnings.
- Bouton Fonksyon (ESC, ANWO, DESANN, ANTRE): Used for navigating menus and adjusting settings on the LCD.
3.3 Koneksyon Panèl Dèyè
- Pò kominikasyon RS485: For external communication and monitoring.
- Tèminal baz: Essential for safety grounding.
- Antre batri: Connects to the 24V battery bank.
- Pò kontak sèk: Pou kontwòl ekstèn oswa siyalizasyon.
- Built-in Wi-Fi Module: For wireless monitoring.
- Antre AC: Connects to grid utility or generator AC power.
- AC Sòti: Konekte ak chaj kay la.
- Antre PV: Li konekte ak panèl solè yo.
- Bouton On/Off: Kontwole kouran prensipal ki bay envèstisè a.
4. Enstalasyon & Enstalasyon
Proper installation is crucial for the safe and efficient operation of your hybrid solar inverter. Ensure all connections are made by a qualified electrician and adhere to local electrical codes.
4.1 Monte varyateur la
- Chwazi yon kote ki sèk, byen ayere, epi pwoteje kont limyè solèy dirèk ak imidite.
- Asire ke gen ase espas ozalantou envèstisè a pou bon sikilasyon lè ak refwadisman.
- Mount the inverter vertically on a sturdy surface using appropriate fasteners.
4.2 Koneksyon fil elektrik
Follow the wiring diagram carefully. All wiring should be performed with the inverter and all power sources disconnected.

Figure 4.1: Solar System Connection Diagram. This diagram illustrates the connections for solar panels, generator, utility grid, 24V battery, and household loads to the inverter. It shows the PV input, battery input, AC input, and AC output terminals.
4.2.1 Koneksyon batri
- Connect the 24V battery bank to the battery input terminals on the inverter. Ensure correct polarity (+ to + and - to -).
- Use appropriate cable gauges for the battery connections to handle the expected current.
- The ANJ-3KW-LV-WIFI model supports a 24-volt DC system and is recommended for use with batteries of at least 100 ampere-hours capacity.

Figure 4.2: Inverter Battery Connection. This diagram shows wiring configurations for both 12-volt and 24-volt battery systems, emphasizing correct series/parallel connections for the desired voltage.
4.2.2 PV (Solar Panel) Connection
- Connect the solar panel array to the PV input terminals. Observe correct polarity.
- Asire w ke volim total sikwi ouvè atage of the PV array does not exceed 500VDC.
- Volim MPPT latage range is 60-450VDC. Ensure your PV array voltage falls within this range for optimal charging.
4.2.3 Koneksyon Antre AC
- Connect the utility grid or generator AC power to the AC input terminals.
- The inverter supports 110/120VAC input with auto-sensing frequency (50/60Hz).
4.2.4 Koneksyon Sòti AC
- Connect your household loads or appliances to the AC output terminals.
- The inverter provides 3000W continuous AC output at 110/120VAC.
4.3 Premye pouvwa-up
- Apre tout koneksyon yo byen fèm, limen disjonktè batri a an premye.
- Then, switch on the PV array breaker (if applicable).
- Finally, switch on the AC input breaker (if applicable) and the inverter's main power switch.
- Observe the LCD display for initial boot-up and status indicators.
5. Operasyon
The inverter offers various configurable settings to optimize power management based on your specific needs.
5.1 Ekran LCD ak Paramèt
The LCD display provides real-time information and allows you to configure operational parameters using the function buttons.
- Sèvi ak la UP epi DESANN bouton pou navige nan opsyon meni yo.
- Peze ANTRE pou chwazi yon opsyon oubyen konfime yon paramèt.
- Peze ESC to exit a menu or cancel an action.
5.2 Charging Priority Modes
These settings determine how the battery bank is charged from available power sources.

Figure 5.1: Charger Source Priority. This diagram illustrates three charging priority options: Solar First (solar panels charge first, AC input only if solar is unavailable), Solar and AC Input Simultaneously (both solar and utility charge at the same time), and Solar Only (solar energy is the exclusive charging source).
- Solè An Premye: Prioritizes solar power for charging. AC input will only charge the battery when solar power is insufficient or unavailable.
- AC Priority (Utility Priority): Prioritizes AC input (utility or generator) for charging. Solar power will supplement or take over if AC input is unavailable.
- Solè sèlman: The inverter will only charge the battery bank from solar power. AC input will not be used for charging.
5.3 Output Priority Modes
These settings determine the power source for your connected loads.

Figure 5.2: Output Source Priority. This diagram shows three output priority options: Solar First (power from solar first, AC input supplements if solar is insufficient), AC First (redirects AC input to power loads, uses solar/batteries when AC is unavailable), and DC Priority (prioritizes solar first, then battery, then AC input only when voltage drops to a programmable value).
- Solar First (PV Priority): Prioritizes solar power to supply loads. If solar power is insufficient, the battery bank will supplement, and then AC input will be used.
- AC First (Mains Priority): Prioritizes AC input (utility or generator) to power loads. If AC input is unavailable, the inverter will switch to battery power.
- DC Priority (Battery Priority): Prioritizes solar power first, then battery power. AC input will only engage when the battery voltage drops below a programmable threshold.
5.4 Siveyans Wi-Fi
The built-in Wi-Fi module allows for remote monitoring of your inverter's performance and status via a dedicated application. Registration may be required to access this feature.

Figure 5.3: Wi-Fi Monitoring. This image depicts a user monitoring the hybrid inverter's status wirelessly via a smartphone application, highlighting the convenience of the built-in Wi-Fi feature.
6. Antretyen
Regular maintenance helps ensure the longevity and optimal performance of your Aninerel Hybrid Solar Inverter.
- Netwayaj: Netwaye deyò envèstisè a detanzantan avèk yon twal sèk. Asire w ouvèti vantilasyon yo pa gen pousyè ak debri.
- Koneksyon: Annually check all electrical connections (battery, PV, AC input/output) for tightness and corrosion. Tighten any loose connections.
- Anviwònman: Asire w ke anviwònman enstalasyon an rete nan limit tanperati ak imidite espesifye yo.
- Firmware: Tcheke manifakti a websit la pou nenpòt mizajou firmwèr ki disponib pou amelyore pèfòmans oswa nouvo fonksyonalite.
NAN. Depanaj
Seksyon sa a bay solisyon pou pwoblèm komen ou ka rankontre. Si pwoblèm nan pèsiste, kontakte sèvis kliyan.
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Envèstisè a pa limen | Pa gen koneksyon batri oswa volim batri a batage; Power switch off; Loose wiring. | Tcheke koneksyon batri ak voltage; Ensure power switch is ON; Verify all wiring is secure. |
| Pa gen pwodiksyon AC | Overload; Short circuit on output; Inverter in fault mode; Output priority setting. | Reduce load; Check for short circuits; Refer to LCD fault codes; Adjust output priority settings. |
| Battery not charging from solar | Low PV voltage; Incorrect PV connection; Solar charging disabled; Faulty solar panels. | Tcheke volim panèl fotovoltaik latage (must be >60VDC); Verify PV polarity; Check charging priority settings; Inspect solar panels. |
| Avètisman surchof | Insufficient ventilation; Excessive ambient temperature; Overload. | Ensure clear airflow around inverter; Relocate to cooler area; Reduce connected load. |
| Siveyans Wi-Fi a pa fonksyone | No Wi-Fi signal; Incorrect app configuration; Registration issue. | Check Wi-Fi signal strength; Reconfigure app settings; Contact support for registration issues. |
8. Espesifikasyon
Technical specifications for the Aninerel 3000W Hybrid Solar Inverter ANJ-3KW-LV-WIFI:
| Karakteristik | Spesifikasyon |
|---|---|
| Nimewo Modèl | ANJ-3KW-LV-WIFI |
| Sòti pouvwa kontinyèl | 3000W |
| Sòti pouvwa pik | 6000W |
| DC Antre Voltage | 24V |
| AC Sòti Voltage | 110V AC |
| Sòti Ond | Vag sinis pi |
| Max. PV Antre pouvwa | 4000W |
| MPPT Controller Current | 100A |
| Max. PV Open Circuit Voltage | 500VDC |
| PV Array MPPT Voltage Range | 60-450VDC |
| Max. AC Antre Kouran | 60A |
| Sòti Frekans | 50/60Hz (deteksyon oto) |
| Konpatibilite batri | AGM, GEL, Lead-acid, Li-ion, LiFePO4 (24V) |
| Pwoteksyon Rating | IP65 |
| Dimansyon pwodwi | 15 x 6.98 x 18 pous |
| Pwa atik | 16.5 liv |
9. Garanti & Sipò
For warranty information, please refer to the warranty card included with your product or visit the official Aninerel website. For technical support, troubleshooting assistance, or service inquiries, please contact Aninerel customer service through their official channels.
Manufacturer: Shenzhen Anenji Energy Technology Co.,Ltd