Elitech TM-2TH

Elitech TM-2TH Digital Thermometer Hygrometer Instruction Manual

Model: TM-2TH | Brand: Elitech

Entwodiksyon

Thank you for choosing the Elitech TM-2TH Digital Thermometer Hygrometer. This device is designed for precise monitoring of temperature and humidity in various environments, including refrigerators, freezers, wine cabinets, and more. Please read this manual carefully before use to ensure proper operation and to maximize the lifespan of your device.

Karakteristik pwodwi

Elitech TM-2TH features overview showing temperature and humidity ranges, battery life, and installation options.

The Elitech TM-2TH offers precision monitoring with a temperature range of -10°C to 50°C and a humidity range of 10% to 95% RH. It features ultra-long battery life, flexible installation options, and a °C/°F toggle function.

Elitech TM-2TH display showing 0.1°C precision and 5%RH accuracy.

This device provides high accuracy with ±1°C temperature accuracy and ±5% RH precision (within 30%~85% RH range), ensuring reliable readings for critical environments.

Elitech TM-2TH displaying MAX and MIN temperature records.

The TM-2TH automatically records and displays maximum and minimum temperature and humidity values, allowing users to track environmental fluctuations over time.

Elitech TM-2TH showing three installation methods: hanging, standing, and magnetic attachment.

Designed for versatility, the thermometer hygrometer can be installed in three ways: hanging via its integrated hook, standing on a flat surface, or magnetically attached to metal surfaces.

Elitech TM-2TH used in various locations: wine cabinet, medicine cabinet, refrigerator, camping box, and baby's fridge.

The TM-2TH is suitable for a wide range of applications, including monitoring conditions in wine cabinets, medicine cabinets, refrigerators, camping boxes, and baby's fridges.

Espesifikasyon

ModèlTM-2TH
Ranje Tanperati-10 ° C a 50 ° C (14 ° F a 122 ° F)
Presizyon Tanperati± 1 ° C (± 1.8 ° F)
Range imidite10% a 95% RH
Presizyon imidite±5% RH (within 30%~85% RH)
Kalite batri1 x CR2032 (enkli)
Pwodwi ReferansTM-2TH-2Pack
Dimansyon pake a (apeprè)15.4 x 9.5 x 6.5 cm
Pwa pake a (apeprè)90 gram
Peyi orijinLachin

Enstalasyon

1. Enstalasyon batri

  1. Jwenn kouvèti konpatiman batri a sou dèyè aparèy la.
  2. Open the cover by sliding or gently prying it off.
  3. Insert one CR2032 battery, ensuring the positive (+) side faces upwards.
  4. Replace the battery compartment cover securely. The device should power on automatically and display current temperature and humidity.

2. Plasman

The TM-2TH offers multiple placement options:

  • Kanpe: Sèvi ak sipò entegre a pou mete aparèy la sou nenpòt sifas plat.
  • Pann: Utilize the built-in hook to hang the device from a rack or hook.
  • Mayetik: Attach the device to any metallic surface, such as a refrigerator door, using its magnetic backing.

Choose a location that provides accurate readings for the area you wish to monitor, avoiding direct sunlight or heat sources.

Enstriksyon Operasyon

1. Reading Display

Upon activation, the device will display the current temperature and relative humidity. The temperature is typically shown in degrees Celsius (°C) or Fahrenheit (°F), and humidity as a percentage (%).

2. Chanje Inite Tanperati (°C/°F)

Locate the °C/°F button, usually on the back or side of the device. Press this button to toggle between Celsius and Fahrenheit temperature units.

3. Viewing MAX/MIN Records

The device automatically records the highest (MAX) and lowest (MIN) temperature and humidity values since the last reset. To view dosye sa yo:

  • Peze a MAX/MIN Peze bouton an yon fwa pou montre valè maksimòm ki anrejistre yo.
  • Peze a MAX/MIN button again to display the minimum recorded values.
  • Press it a third time to return to the current temperature and humidity display.

4. Resetting MAX/MIN Records

To clear the recorded MAX/MIN values and start a new recording cycle:

  • Pandan ke viewing the MAX or MIN records, press and hold the MAX/MIN bouton pou apeprè 3 segonn.
  • The display will flash, indicating that the records have been reset to the current temperature and humidity.

Antretyen

1. Ranplasman batri

When the display becomes dim or the device stops functioning, it is time to replace the CR2032 battery. Follow the battery installation steps in the "Setup" section to replace the battery.

2. Netwayaj

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or immerse the device in water. Ensure the sensor openings are free from dust and debris for accurate readings.

3. Depo

If the device will not be used for an extended period, remove the battery to prevent leakage and store it in a cool, dry place.

Depanaj

PwoblèmKòz posibSolisyon
Pa gen ekspozisyon oswa ekspozisyon fèbBatri a mouri oswa li mal enstale.Replace the CR2032 battery or ensure it is installed with correct polarity.
Lekti kòrèkSensor blocked or device placed near heat/cold source.Ensure sensor openings are clear. Relocate the device to a more representative area. Allow time for readings to stabilize.
MAX/MIN values not resettingBouton pa kenbe ase lontan.Press and hold the MAX/MIN button for at least 3 seconds until the display flashes.

Garanti ak sipò

Elitech provides a standard warranty for its products. For specific warranty terms, technical support, or service inquiries, please refer to the warranty card included with your purchase or visit the official Elitech websit la. Tanpri konsève prèv acha ou a pou reklamasyon garanti.

Elitech Ofisyèl Websit: www.elitechlog.com

© 2026 Elitech. Tout dwa rezève.

Ask a question about this manual