1. Entwodiksyon

The Runleader RL-BI069C is a TFT LCD battery indicator and voltage meter designed to monitor battery power level, percentage, voltage, and total operating hours. This device is compatible with various DC 12V/24V/36V/48V battery types, including Lead acid, GEL, LiFePO4, AGM, and 18650 lithium batteries. It also features a customizable channel for specific battery voltage settings. This manual provides detailed instructions for installation, operation, and maintenance of your RL-BI069C unit.

Runleader RL-BI069C Battery Indicator

Figi 1.1: The Runleader RL-BI069C TFT LCD Battery Indicator Voltage Mèt.

2. Karakteristik kle

  • Siveyans batri: Displays battery power level, percentage, voltage, and total operating hours.
  • Konpatibilite pil laj: Supports DC 12V/24V/36V/48V Lead acid, GEL, LiFePO4, AGM, 18650 lithium, and custom battery types.
  • Voltage Ranje Mezi: DC 8V a 65V.
  • Low Battery & Voltage Reminders: Alerts for low battery power (10%-60% settable) and over/under voltage (DC 8.5V to 65V settable).
  • Working Hours Tracking: Records total operating hours from 0 to 99,999 hours.
  • Ekran TFT LCD: Provides clear, viewable data from all angles.
  • Karakteristik avanse: Voltage output function, parameter editing via Runleader PG600 programmer (sold separately), CAN/485 communication for data transfer, and firmware update capability.
  • Rezistans dlo: Favorable water resistance up to IP65.

3. Pwodwi souview ak Pwodwi pou Telefòn

The RL-BI069C unit comes with essential accessories for installation and operation. Familiarize yourself with these components before proceeding with setup.

Runleader RL-BI069C Product Accessories

Figi 3.1: Included accessories for the RL-BI069C. This includes the main product unit, connector wiring, mounting bracket, M4 flange nuts, a rubber ring, and a user manual.

Kontni pake:

  • RL-BI069C Battery Indicator (x1)
  • Connector Wiring (x1)
  • Mounting Support (x1)
  • M4 Flange nwa (x2)
  • Rubber Ring (x1)
  • Manyèl itilizatè (x1)

4. Espesifikasyon

Detailed specifications for the Runleader RL-BI069C.

Runleader RL-BI069C Product Dimensions

Figi 4.1: Detailed dimensions of the RL-BI069C unit, showing a diameter of 56.20mm (2.21 inches) and a depth of 37.65mm (1.48 inches).

KarakteristikDeskripsyon
ModèlRL-BI069C
MateryèlVè, Plastik
Dimansyon atik (L x W x H)2.52 x 2.52 x 2.13 pous (64 x 64 x 54 mm)
Gwosè dekoupaj panèlφ51.50mm (φ2.03 inches)
Batri Voltage RangeDC 8V pou 65V
Hour Measurement Range0 a 99,999 èdtan
Pousantaj ki enpèmeyabIP65

5. Enstalasyon ak Enstalasyon

Follow these steps to properly install your Runleader RL-BI069C battery indicator.

5.1 Panel Mounting

  1. Prepare Dekoupaj Panèl la: Drill a hole with a diameter of φ51.50mm (φ2.03 inches) in your desired mounting location.
  2. Mete Inite: Insert the RL-BI069C unit into the cutout from the front.
  3. Inite Sekirite: Use the provided mounting bracket and M4 flange nuts to secure the unit from the rear of the panel. Ensure the rubber ring is in place for a tight seal.

5.2 Koneksyon pouvwa

The RL-BI069C can be connected in several ways:

  • Koneksyon dirèk: Connect the "+" and "-" poles of the 8-hole connector assembly directly to your battery's positive and negative terminals. This will power the gauge and enable basic functions.
  • External Key Switch Connection: For applications requiring power control, connect the "+" pole through an external key switch to the battery's positive terminal.
  • Activate Hour Meter Function: To enable the total hours tracking function, connect the "HMR+" or "HMR-" pole on the connector assembly. Refer to the wiring diagram for specific connections.
Runleader RL-BI069C Mounting and Power Connection Diagram

Figi 5.1: Illustration of panel cutout size, plug-in mounting, direct power connection, external key switch connection, and enabling the timing function.

6. Operasyon Enstriksyon

Once installed and powered, the RL-BI069C will display various battery and operational data on its TFT LCD screen.

6.1 Fonksyon ekspozisyon

The full-sight TFT LCD screen simultaneously displays multiple functions:

  • Batri Voltage: Montre volim aktyèl latage nan batri a konekte.
  • Power Progress Bars: Visual representation of battery charge level. These bars can be configured to display in multiple colors (red, green, blue).
  • Pousan pouvwatage: Numerical display of the remaining battery charge.
  • Total Hours: Records the cumulative operating time of the equipment.
Runleader RL-BI069C Display Functions

Figi 6.1: The TFT LCD screen displaying battery voltage, power progress bars, power percentage, and total hours. Also shown are selectable colors for progress bars and battery type/voltage range selection options.

6.2 Battery Type and Voltage Seleksyon

The unit supports various battery types and voltage ranges. You can select from preset options or configure a custom channel:

  • Kalite batri: Lead acid, GEL, LiFePO4, AGM, 18650 lithium, and Custom.
  • Voltage Range: 12V, 24V, 36V, 48V.
  • Anviwònman pèsonalize: For custom battery types, you can set the full and empty voltage values to ensure accurate readings.

6.3 Low Battery and Voltage Reminders

The RL-BI069C provides alerts to notify you of critical battery conditions:

  • Avètisman batri ki ba: When the battery power drops below a preset percentage, a low battery icon will illuminate. The reminder percentage can be set between 10% and 60%.
  • Sou-voltage & Under-voltage Alerts: The unit can alert you if the voltage exceeds or falls below preset values. These alerts are indicated by a red voltage value and an alert icon. The over-voltage ak anba-voltage alert settings range from DC 8.5V to 65V.
Runleader RL-BI069C Battery Volt and Power Alerts

Figi 6.2: The display showing options for setting low voltage, segondè voltage, and low battery percentagrapèl yo.

6.4 Working Hours Tracking

The gauge automatically tracks total operating hours when the battery-powered equipment is in use. The hour measurement range is from 0 to 99,999 hours.

7. Programming and Communication

The RL-BI069C offers advanced configuration and data transfer capabilities.

7.1 Parameter Editing with PG600 Programmer

Parameters such as low battery reminders, over-voltage ak anba-voltage reminders, colors of LED bars, and backlight modes can be edited using Runleader's PG600 programmer (sold separately).

7.2 Kominikasyon Done

The unit supports CAN/485 communication, allowing for the transfer of working data to compatible equipment.

Runleader RL-BI069C Programming and Communication

Figi 7.1: Diagrams illustrating parameter editing with the PG600 programmer and data communication via CAN/485.

8. Antretyen

The Runleader RL-BI069C is designed for durability and minimal maintenance.

  • Rezistans dlo: The unit features an IP65 waterproof rating, protecting it from dust and low-pressure water jets. Ensure proper installation with the rubber ring to maintain this rating.
  • Netwayaj: Clean the display and housing with a soft, damp twal. Evite pwodui netwayaj abrazif oswa solvan.
  • Enspeksyon: Periodically check wiring connections for security and signs of wear or corrosion.
Runleader RL-BI069C Waterproof Design

Figi 8.1: The RL-BI069C demonstrating its IP65 waterproof design, suitable for various environments.

NAN. Depanaj

If you encounter issues with your RL-BI069C, refer to the following common troubleshooting steps:

  • Pa gen ekspozisyon/pouvwa:
    • Check all power connections to ensure they are secure and correctly wired to the battery's positive and negative terminals.
    • Verifye vol batri atage is within the operating range (DC 8V to 65V).
    • Inspect the connector wiring for any damage or breaks.
  • Lekti ki pa kòrèk:
    • Ensure the correct battery type and voltage range are selected in the unit's settings.
    • For custom battery types, verify that the full and empty voltage settings are accurate.
    • Check for stable power supply to the unit. Fluctuations can affect readings.
  • Hour Meter Not Tracking:
    • Confirm that the "HMR+" or "HMR-" pole is correctly connected to activate the hour meter function as per the installation instructions.
    • Ensure the equipment is actively running and drawing power from the battery.
  • Alerts Not Functioning:
    • Verify that the low battery percentage, sou-voltage, ak anba-voltage alert values are correctly set in the unit's configuration.
    • Check if the conditions for the alerts are actually being met (e.g., battery voltage is indeed below the low voltage papòt).

Si etap sa yo pa rezoud pwoblèm nan, tanpri kontakte sèvis kliyan.

10. Aplikasyon

The Runleader RL-BI069C is suitable for a wide range of equipment powered by DC 12V, 24V, 36V, or 48V Lead acid, GEL, LiFePO4, AGM, or 18650 lithium batteries. Common applications include:

  • Gòlf kabwa
  • Charyo
  • Motorhomes
  • Mowers gazon
  • Leaf Trimmers
  • Scrubber Machines
  • Dèlko solè
Runleader RL-BI069C used in a golf cartRunleader RL-BI069C used in a forkliftRunleader RL-BI069C used in a motorhome

Figi 10.1: Examples of equipment where the RL-BI069C can be used, including golf carts, forklifts, and motorhomes.

11. Garanti ak sipò

Runleader products are manufactured to high-quality standards. For warranty information and technical support, please refer to the official Runleader websit la oubyen kontakte konsesyonè otorize ou a. Kenbe resi acha ou a pou reklamasyon garanti.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.