AUX Trial 12+12+12 (Outdoor Unit AM4-H28/4DR3C)

AUX DC Inverter Multi-Split Air Conditioner System (Trial 12+12+12) User Manual

Model: Trial 12+12+12 (Outdoor Unit AM4-H28/4DR3C)

1. Entwodiksyon

This manual provides comprehensive instructions for the AUX DC Inverter Multi-Split Air Conditioner System, designed for efficient cooling and heating of multiple rooms. This system utilizes R-32 refrigerant and features advanced DC Inverter technology for optimal performance and energy savings. Please read this manual thoroughly before installation, operation, or maintenance to ensure correct usage and to prevent damage to the unit or injury to personnel.

2. Enfòmasyon sou Sekirite

Always adhere to the following safety precautions to prevent electric shock, fire, injury, or damage to the unit:

  • Installation must be performed by qualified and authorized personnel only, in accordance with national wiring regulations.
  • Asire w ke ekipman pou pouvwa a koresponn ak espesifikasyon aparèy la.
  • Pa eseye repare oswa modifye aparèy la tèt ou. Kontakte pèsonèl sèvis kalifye.
  • Asire bon baz pou anpeche chòk elektrik.
  • Do not block the air inlet or outlet of the indoor or outdoor units.
  • Kenbe timoun yo lwen aparèy la pandan l ap fonksyone.
  • The refrigerant R-32 is mildly flammable. Handle with care and ensure proper ventilation during installation and servicing.

3. Pake kontni

Upon unpacking, verify that all components are present and undamaged. The standard package for the AUX DC Inverter Multi-Split Air Conditioner System (Trial 12+12+12) typically includes:

  • One (1) Outdoor Unit (Model: AM4-H28/4DR3C)
  • Three (3) Indoor Units (e.g., 12000 BTU units, or a combination of 9000 BTU and 12000 BTU units as per your specific order)
  • Three (3) Remote Controls for Indoor Units
  • Manyèl Itilizatè ak Gid Enstalasyon
  • Mounting accessories for indoor units

Note: Specific indoor unit models and quantities may vary based on the purchased configuration.

4. Espesifikasyon

The following table outlines the key technical specifications for the AUX DC Inverter Multi-Split Air Conditioner System:

KarakteristikSpesifikasyon
MakAUX
Modèl Inite DeyòAM4-H28/4DR3C
Cooling Capacity (Total)29650 BTU
Heating Capacity (Total)30776 BTU
Pwovizyon pou pouvwaSingle-phase 220-240V/1/50Hz
VYE6.3
SCOP4.1
Klas enèjiA++A+
RefrijeranR-32
Outdoor Unit Airflow3100 m³/h
Outdoor Unit Sound Pressure Level56 dB
Operating Limit (Temperature)-35°C pou +55°C
Outdoor Unit Dimensions (LxWxH)832 x 328 x 655 mm
Gwosè Liy likid1/4 pous
Gas Line Size3/8 pous
Longè Liy Maksimòm70 mèt
Maximum Single Line Length30 mèt
Maximum Dislevel (Outdoor to Indoor)15 mèt
Maximum Dislevel (Between Indoor Units)10 mèt
Indoor Unit (9000 BTU) Cooling Capacity11260 BTU
Indoor Unit (9000 BTU) Heating Capacity11260 BTU
Indoor Unit (9000 BTU) Airflow800 m³/h
Indoor Unit (9000 BTU) Dimensions (LxWxH)792 x 200 x 285 mm
Indoor Unit (9000 BTU) Connections1/4 inch, 3/8 inch
Indoor Unit (9000 BTU) Drain Diameter16.5 mm
Indoor Unit (9000 BTU) Minimum Noise Level19 dB
Indoor Unit (12000 BTU) Cooling Capacity12625 BTU
Indoor Unit (12000 BTU) Heating Capacity12966 BTU
Indoor Unit (12000 BTU) Airflow600 m³/h
Indoor Unit (12000 BTU) Dimensions (LxWxH)750 x 200 x 285 mm
Indoor Unit (12000 BTU) Connections1/4 inch, 3/8 inch
Indoor Unit (12000 BTU) Drain Diameter16.5 mm
Indoor Unit (12000 BTU) Minimum Noise Level19 dB
Pwa total120 kg
Kalite kontwòlKontwòl Remote

5. Enstalasyon

Installation of this multi-split air conditioning system requires specialized knowledge and tools. It must be performed by certified HVAC technicians.

5.1 Gid jeneral

  • Seleksyon kote: Choose a location for the outdoor unit that allows for adequate airflow and is away from direct sunlight or heat sources. Indoor units should be placed to ensure even air distribution.
  • Montaj: Securely mount indoor and outdoor units according to the provided installation diagrams.
  • Tiyo frijidè: Connect the liquid and gas lines between the outdoor unit and each indoor unit. The system uses R-32 refrigerant, which operates at similar pressures to R410A. Ensure compatibility of tools (manifold gauge, leak detector, recovery unit) with R-32. R-32 is a pure gas, simplifying charging procedures compared to refrigerant mixtures.
  • Drenaj: Install condensate drain pipes with proper slope to ensure efficient water removal.
  • Fil elektrik: Connect the power supply and communication cables according to the wiring diagram. Ensure all connections are secure and properly insulated.
  • Aspirasyon ak Chaje: Evacuate the system to remove non-condensable gases and moisture. Charge with the correct amount of R-32 refrigerant.

For detailed installation steps, refer to the separate Installation Manual provided with the product.

AUX DC Inverter Multi-Split Air Conditioner System outdoor unit.
Image showing the outdoor unit of the AUX DC Inverter Multi-Split Air Conditioner System. This unit connects to multiple indoor units for comprehensive climate control.

6. Operasyon

Your AUX air conditioner system is controlled via a wireless remote control. Familiarize yourself with the remote control functions for optimal use.

6.1 Operasyon debaz

  • Limen/Etenyen: Peze bouton pouvwa a sou kontwòl remote la pou limen oswa etenn inite a.
  • Seleksyon mòd: Select desired operating mode (Cool, Heat, Fan, Dry, Auto) using the Mode button.
  • Ajisteman Tanperati: Use the temperature up/down buttons to set the desired room temperature.
  • Vitès fanatik: Adjust fan speed (Auto, Low, Medium, High) to your preference.

6.2 Fonksyon avanse

  • 24H revèy: This function allows you to set a specific time for the air conditioner to turn on or off within a 24-hour period.
  • Fonksyon Mwen Santi: When activated, the remote control's built-in temperature sensor measures the ambient temperature and sends the data to the indoor unit, allowing the unit to adjust its operation for enhanced comfort around the remote control's location.
  • Super refwadisman: Provides rapid cooling to quickly reach the desired temperature.
  • Fonksyon entelijan: Pressing the 'Smart' button on the remote control enables the air conditioner to operate in the most comfortable mode based on the current room temperature, automatically adjusting settings.
  • Fonksyon dòmi: Optimizes temperature and fan speed settings during sleep for comfort and energy efficiency.
  • Wi-Fi Control (Optional): If equipped with the optional Wi-Fi module, the system can be controlled remotely via a smartphone application. Refer to the Wi-Fi module manual for setup instructions.

7. Karakteristik

The AUX DC Inverter Multi-Split Air Conditioner System incorporates several advanced features for superior performance and user experience:

  • Full DC Inverter Technology: Features a digital control signal, DC Inverter compressor, DC Inverter motors on both indoor and outdoor units, and an electronic expansion valve. This ensures low noise levels and high efficiency.
  • DC Inverter Twin Rotary Compressor: The newly designed BLDC Inverter twin rotary compressor provides improved balance and reduced vibrations, leading to maximum quietness and excellent efficiency and energy savings.
  • Electronic Expansion Valve: Precisely controls refrigerant flow for optimal system performance.
  • Low Voltage Operasyon: The outdoor unit can operate within a wide voltage range (176V to 264V), ensuring stable performance even with voltage fluctuations.
  • Auto-diagnosis and Automatic Protection: The system can detect operational anomalies and activate protective measures.
  • Chofaj tanperati ki ba: Capable of providing effective heating even at outdoor temperatures as low as -15°C.
  • Dekonjle otomatik: Automatically defrosts the outdoor unit coil to maintain heating efficiency in cold conditions.
  • 8°C Rekòmanse: A function that maintains a minimum temperature of 8°C to prevent freezing in unoccupied rooms during winter.
  • Anti-mold Function: After the air conditioner is turned off, the indoor fan continues to operate for 30 seconds to dry any condensation inside the indoor unit, preventing mold formation.
  • Filtraj Avanse: Includes an active carbon filter and a 4-in-1 filter system for improved air quality.
  • Rubidium Magnet Compressor: Enhances efficiency and reduces power consumption through increased gas molecule compression.
  • Optimized Heat Exchanger Design: The external heat exchanger is designed to maximize heat transfer, improving the refrigeration circuit's efficiency and preventing ice blockages. It also supports long-distance connections between units without reducing cooling capacity.

8. Antretyen

Regular maintenance ensures the longevity and efficient operation of your air conditioning system. Always turn off the power supply before performing any maintenance.

8.1 Antretyen Inite Enteryè a

  • Netwayaj filtè: Clean the air filters every two weeks or more frequently depending on usage and air quality. Remove filters, wash with lukewarm water, dry thoroughly, and reinsert.
  • Netwayaj Sifas Inite a: Siye sifas inite andedan an avèk yon twal mou,amp twal. Pa sèvi ak savon ki fò oswa pwodui netwayaj abrazif.
  • Anti-mold Function: Utilize the built-in anti-mold function to keep the indoor coil dry.

8.2 Antretyen Inite Eksteryè a

  • Netwayaj Bobin: Periodically check and clean the outdoor unit's coil to remove dust, leaves, and other debris that can obstruct airflow. This should ideally be done by a professional.
  • Obstak klè: Ensure that there are no obstructions around the outdoor unit that could impede airflow.

8.3 Sèvis Pwofesyonèl

It is recommended to have your system professionally serviced at least once a year by a qualified technician. This includes checking refrigerant levels, electrical connections, and overall system performance.

NAN. Depanaj

Before contacting service personnel, review pwoblèm komen sa yo ak solisyon potansyèl yo:

PwoblèmKòz posibSolisyon
Inite pa limenNo power supply; Remote control batteries low; Circuit breaker trippedCheck power connection; Replace batteries; Reset circuit breaker
Refwadisman/chofaj ensifizanDirty air filters; Blocked outdoor unit; Incorrect mode/temperature setting; Low refrigerantClean filters; Clear obstructions; Adjust settings; Contact technician for refrigerant check
Bri etranjLoose parts; Fan obstruction; Refrigerant flow noise (normal)Check for loose parts; Clear obstructions; If persistent or loud, contact technician
Flit dlo nan inite andedan anBlocked drain pipe; Improper installationClear drain pipe; Contact technician for inspection
Remote kontwòl pa travayBatteries low/dead; Obstruction between remote and unitReplace batteries; Ensure clear line of sight

The system features an auto-diagnosis function. If an error code appears on the display, consult the detailed troubleshooting section in the full user manual or contact customer support with the error code.

10. Garanti ak sipò

Your AUX DC Inverter Multi-Split Air Conditioner System is covered by a manufacturer's warranty.

  • Garanti faktori: A 5-year factory warranty is provided for certain components.
  • Garanti pwodwi: A general 2-year product warranty applies.

Please refer to your purchase documentation for specific warranty terms and conditions, as these may vary by region and retailer. For warranty claims, technical support, or service requests, please contact your authorized dealer or the AUX customer service department.

Ask a question about this manual