Thank you for choosing the SEBSON Recessed Ceiling Motion Detector. This device is designed for indoor use to automatically control lighting based on motion and ambient light levels. Please read this manual carefully before installation and operation to ensure proper function and safety.

Devan view of the SEBSON recessed ceiling motion detector with key specifications overlaid: 8m/360° detection, up to 1000W LED, IP20, 10sec-30min timer, 3-2000 LUX, 230V.
Figi 1: Plis paseview of the motion detector and its main features.

2. Enstriksyon Sekirite

  • Enstalasyon an dwe fèt pa yon elektrisyen kalifye, dapre règleman lokal yo sou fil elektrik.
  • Disconnect power at the main circuit breaker before installation or maintenance.
  • Do not exceed the maximum load capacity of the detector (2000W for incandescent, 1000W for LED).
  • Pwodwi sa a fèt pou itilize andedan kay la sèlman. Evite ekspoze a imidite oswa tanperati ekstrèm.
  • Asire bon vantilasyon alantou aparèy la.

3. Pwodwi Features

  • Indoor motion detector for recessed ceiling mounting.
  • Wide detection range of 8 meters and 360 degrees.
  • Adjustable operating duration from 10 seconds to 30 minutes.
  • Adjustable ambient light sensitivity from 3 to 2000 lux.
  • Compatible with LED lighting (max 1000W) and incandescent bulbs (max 2000W).
  • 3-wire connection for reliable operation.

4. Pake kontni

  • 1x SEBSON Recessed Ceiling Motion Detector (Anthracite)
  • 1x manyèl enstriksyon

5. Enstalasyon

Enpòtan: Ensure power is disconnected at the main circuit breaker before starting installation.

  1. Prepare a mounting hole in the ceiling with a diameter of 63-66 mm. Ensure there is sufficient depth (minimum 45 mm) for the detector.
  2. Connect the wiring according to the diagram below. The detector requires a 3-wire connection (Live, Neutral, Switched Live).
  3. Insert the detector into the prepared hole. The spring clips will secure it in place.
  4. Restore power and test the functionality.

5.1. Pwodwi souview ak dimansyon

Devan view of the SEBSON recessed ceiling motion detector in anthracite color.
Figi 2: Devan view of the motion detector. This image shows the anthracite-colored circular housing with the central infrared sensor dome.
Technical drawing showing the dimensions of the motion detector: 75mm diameter, 42mm height, 60mm internal width, 34mm internal height, 31mm spring length, 3mm bezel thickness.
Figure 3: Detailed dimensions of the motion detector. The overall diameter is 75mm, and the height is 42mm. The mounting hole diameter should be between 63-66mm.
Side view diagram illustrating the recessed installation, showing a minimum installation depth of 45mm and a ceiling thickness of up to 20mm.
Figure 4: Installation depth requirement. A minimum depth of 45mm is needed for proper recessed mounting.
Dèyè view of the motion detector showing the wiring terminal block and spring clips.
Figi 5: Dèyè view showing the wiring terminal. This is where the Live, Neutral, and Switched Live wires are connected.

6. Operasyon ak Ajisteman

The motion detector features two adjustable dials on the back for 'TIME' (duration) and 'LUX' (light sensitivity).

Dèyè view of the motion detector showing the 'TIME' and 'LUX' adjustment dials. The TIME dial ranges from 10s to 30min, and the LUX dial from 3 to 2000 lux.
Figure 6: Adjustment dials for TIME and LUX settings.

6.1. TIME Adjustment

The 'TIME' dial controls how long the connected light remains on after motion is detected and no further motion is sensed. Rotate the dial to set the desired duration:

  • 10s: Minimum duration (10 seconds).
  • 30min: Maximum duration (30 minutes).

6.2. LUX Adjustment

The 'LUX' dial determines the ambient light level at which the detector will activate. This allows the light to only turn on when it's dark enough.

  • 3: Activates only in very dark conditions (e.g., night).
  • 2000: Activates in all light conditions (day and night).

To set the LUX level, turn the dial to the sun symbol (2000 lux) for testing during daylight. Once satisfied with the detection, adjust the dial towards the moon symbol (3 lux) to the desired ambient light level for automatic operation.

6.3. Ranje deteksyon

Diagram showing the 360-degree detection area of the motion detector, with a maximum range of 8 meters and an installation height between 1.8m and 4m.
Figure 7: Detection range and angle. The detector covers a 360-degree area with a maximum range of 8 meters when installed at a height between 1.8m and 4m.

The detector has a 360° detection angle and a maximum range of 8 meters. Optimal installation height is between 1.8m and 4m. Avoid installing near heat sources, direct sunlight, or areas with significant air movement (e.g., air conditioning vents) to prevent false triggers.

7. Antretyen

The SEBSON motion detector requires minimal maintenance. Ensure the sensor lens is kept clean and free from dust or obstructions. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.

NAN. Depanaj

Pwoblèm Kòz posib Solisyon
Limyè pa limen.
  • Pa gen ekipman pou pouvwa.
  • LUX setting too low (too dark).
  • No motion detected within range.
  • Fil elektrik defo.
  • Check circuit breaker and connections.
  • Adjust LUX dial towards the sun symbol.
  • Ensure motion occurs within the detection zone.
  • Verifye koneksyon fil elektrik yo.
Limyè a rete limen tout tan.
  • Mouvman kontinyèl nan zòn deteksyon an.
  • Anrejistreman TAN an twò long.
  • Wiring error (e.g., switched live permanently connected).
  • Clear detection zone of constant movement.
  • Ajiste kadran TIME a sou yon dire ki pi kout.
  • Check wiring for correct connections.
Limyè a limen san li pa wè okenn mouvman.
  • Heat sources (e.g., heater, direct sunlight).
  • Air currents (e.g., open window, AC vent).
  • Small animals.
  • Relocate detector or remove interfering objects.
  • Ensure stable environment.
  • Adjust sensitivity if possible (this model does not have explicit sensitivity adjustment, but careful placement can help).

9. Espesifikasyon

Mak SEBSON
Nimewo Modèl IR_ES_EA
Koulè Anthracite
Dimansyon (L x W x H) 7.5 x 7.5 x 7.5 cm
Pwa 110 gram
Kalite aliye Ankastre (Plafon)
Dyamèt twou aliye 63-66 mm
Sous pouvwa AC pouvwa
Chaj Maksimòm (Enkandesan) 2000 W
Max Load (LED/Energy Saving) 1000 W
Ranje deteksyon 8 mèt
Ang deteksyon 360°
Operating Duration (TIME) 10 segonn - 30 minit
Ambient Light Sensitivity (LUX) 3 - 2000 luks
Aparèy konpatib Basic lighting controls
Itilizasyon Rekòmande Residential security, commercial security, automation, energy management
Peyi orijin Lachin

10. Garanti ak sipò

For warranty information and technical support, please refer to the documentation provided with your purchase or visit the official SEBSON websit la. Kenbe prèv acha ou pou reklamasyon garanti.

© 2026 SEBSON. Tout dwa rezève.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.