Thank you for choosing the Orient Electric Smartchill 125L Desert Air Cooler. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your new air cooler. Please read these instructions carefully before using the appliance and retain them for future reference.

This desert air cooler is designed to provide effective cooling for residential and commercial spaces up to 538 square feet, featuring a large 125-liter water reservoir, Densenest Honeycomb Pads, and multi-directional airflow.

2. Enstriksyon Sekirite

Toujou swiv prekosyon sekirite debaz yo lè w ap itilize aparèy elektrik pou diminye risk dife, chòk elektrik, ak blesi.

  • Asire ekipman pou pouvwa a voltage matches the cooler's rating (230 Volts).
  • Pa sèvi ak glasyè a si kòd la oswa ploge a domaje.
  • Kenbe glasyè a lwen sous chalè ak limyè solèy dirèk.
  • Do not immerse the cooler or its electrical parts in water.
  • Always unplug the cooler before cleaning, filling, or performing any maintenance.
  • Ensure the cooler is placed on a stable, level surface.
  • Do not allow children to operate the cooler unsupervised.
  • Avoid placing objects on top of the cooler or blocking air inlets/outlets.
  • Use only clean water in the reservoir.

3. Pake kontni

Verifye ke tout atik yo prezan nan pakè a:

  • Main unit (Orient Electric Smartchill 125L Desert Air Cooler)
  • Manyèl itilizatè

4. Enstalasyon

4.1 Debake

Carefully remove the air cooler from its packaging. Inspect the unit for any damage incurred during transit. Retain the packaging for future storage or transport.

4.2 Plasman

Place the air cooler on a firm, level surface in a well-ventilated area. For optimal cooling, position the cooler near an open window or door to allow fresh air intake and exhaust of humid air. The cooler is suitable for rooms up to 538 square feet.

Orient Electric Smartchill 125L Desert Air Cooler in a bedroom setting, demonstrating superior cooling and air delivery.

Image: The Orient Electric Smartchill 125L Desert Air Cooler positioned in a room, illustrating its capacity for superior cooling and high air delivery.

4.3 Wheel Installation (if applicable)

If the wheels are not pre-installed, attach them securely to the base of the cooler. Ensure all wheels are properly fastened before moving the unit. Exercise caution when moving the cooler, especially when the water tank is full, as the wheels may not be designed for heavy loads over rough surfaces.

4.4 Ranpli Rezèvwa Dlo a

Open the water inlet and fill the reservoir with clean water. The cooler has a 125-liter capacity. Monitor the water level indicator to avoid overfilling. For enhanced cooling, you may add ice to the dedicated ice chamber.

Orient Electric Smartchill 125L Desert Air Cooler with Densenest Honeycomb pads and an ice chamber highlighted.

Image: The air cooler showcasing its Densenest Honeycomb pads and the ice chamber for quick cooling.

5. Operasyon Enstriksyon

The Orient Electric Smartchill 125L Desert Air Cooler operates manually with knob controls.

Orient Electric Smartchill 125L Desert Air Cooler showing its control knobs, water level indicator, and 360-swivel wheels.

Image: Close-up of the cooler's control panel with speed and function knobs, water level indicator, and swivel wheels.

5.1 Limen/Etenyen

Plug the power cord into a suitable 230V electrical outlet. Turn the 'Function' knob to the 'Cool' position to start the cooling function. Turn the 'Speed' knob to select your desired fan speed. To turn off, set both knobs to the 'Off' position and unplug the unit.

5.2 Kontwòl vitès

The cooler features 3 fan speed settings. Use the 'Speed' knob to adjust the airflow intensity according to your comfort level.

5.3 Airflow Direction (Louvers)

The cooler is equipped with multi-directional airflow and 4-way deflection louvers. Adjust the horizontal and vertical louvers manually to direct the cool air as needed. The louvers are fully collapsible, which helps prevent dust and insects from entering the unit when not in use.

Orient Electric Smartchill 125L Desert Air Cooler demonstrating multi-directional airflow with arrows indicating air movement.

Image: The air cooler in a living room, illustrating its multi-directional airflow capability.

Orient Electric Smartchill 125L Desert Air Cooler with collapsible louvers, showing how they prevent insects and dust from entering.

Image: A visual representation of the collapsible louvers preventing dust and insects from entering the cooler.

5.4 Ice Chamber Usage

For quicker and more intense cooling, open the ice chamber lid and place ice cubes inside. Close the lid securely after adding ice.

5.5 Endikatè Nivo Dlo

The cooler is equipped with a water level indicator on the front. Monitor this indicator to ensure the water reservoir has sufficient water for continuous cooling. Refill when the level is low.

5.6 Konpatibilite Envèstisè

This air cooler is designed to work seamlessly with inverters, providing uninterrupted cooling during power outages.

6. Antretyen

Antretyen regilye asire pèfòmans optimal ak lonjevite refwadisè lè ou la.

6.1 Cleaning the Densenest Honeycomb Pads

The Densenest Honeycomb Pads are crucial for efficient cooling. Periodically clean them to prevent mineral buildup and maintain airflow. Refer to the diagram below for the cooling process.

Diagram illustrating the cooling process of the Orient Electric air cooler, showing hot air entering, passing through Densenest Honeycomb pads, and cool air being delivered by the fan.

Image: Diagram explaining how the air cooler works, highlighting the Densenest Honeycomb pads and fan technology.

  • Debranche glasyè a nan priz kouran an.
  • Carefully remove the honeycomb pads from their slots.
  • Rinse the pads under running water to remove dust and mineral deposits. For stubborn buildup, soak them in a mild descaling solution.
  • Allow the pads to dry completely before reinserting them.

6.2 Netwayaj Rezèvwa Dlo a

Drain the water from the reservoir using the drain hole located at the bottom. Clean the interior of the reservoir with a soft cloth and mild detergent to prevent algae growth and odors. Rinse thoroughly before refilling.

6.3 Netwaye Eksteryè a

Siye sifas ekstèn glasyè a ak yon twal mou, damp twal. Pa sèvi ak pwodui netwayaj abrazif oswa solvang.

6.4 Depo

If storing the cooler for an extended period, ensure the water reservoir is completely drained and dry. Clean the honeycomb pads and exterior. Cover the cooler to protect it from dust and store it in a dry place.

NAN. Depanaj

Gade tablo ki anba la a pou pwoblèm komen ak solisyon yo:

PwoblèmKòz posibSolisyon
Cooler does not turn onPa gen ekipman pou pouvwaTcheke si kòd kouran an byen branche epi si priz la ap fonksyone.
Pa gen efè refwadismanNivo dlo ki baRanpli rezèvwa dlo a.
Honeycomb pads are dry or cloggedEnsure the water pump is working. Clean the honeycomb pads.
Poor ventilation in the roomEnsure adequate cross-ventilation by opening windows or doors.
Ponp dlo pa macheNivo dlo a twò baRanpli rezèvwa dlo a.
Pump clogged or faultyClean the pump filter. If the issue persists, contact customer support.
Bri etranjFan obstruction or unstable placementCheck for any objects obstructing the fan. Ensure the cooler is on a stable surface.

If the problem persists after attempting these solutions, please contact Orient Electric customer support.

8. Espesifikasyon

Orient Electric Smartchill 125L Desert Air Cooler with dimensions: 69 cm width, 136 cm height, 47 cm depth.

Image: The air cooler displaying its physical dimensions.

KarakteristikDetay
MakOrient Electric
Non modèlSmartchill 125L desert cooler
Nimewo ModèlCD1251H
MateryèlPolypropylène (PP)
Kalite aliyeOtonòm
KoulèBlan
Kapasite Flow Air5000 pye kib pou chak minit
Kontwòl KaliteBouton
Kapasite rezèvwa125 lit
Kouvèti zòn etajJiska 538 pye kare
Pwa atik19 Kilogram
Wattage190 Watts
Kantite Vitès3
Voltage230 Volts
Mòd operasyonManyèl
Dimansyon atik (D x W x H)46.5P x 68.5W x 135.3H santimèt
Karakteristik espesyalAdjustable Speed, Densenest Honeycomb Pads, Fully Collapsible Louvers, Inverter Compatible, Ice Chamber

9. Garanti ak sipò

9.1 Pwodwi Garanti

The Orient Electric Smartchill 125L Desert Air Cooler comes with a 1 ane garanti pwodwi from the date of purchase. This warranty covers manufacturing defects under normal use conditions. Please retain your purchase receipt as proof of purchase for warranty claims.

9.2 Sipò pou Kliyan

For any queries, technical assistance, or warranty claims, please contact Orient Electric customer support. Refer to the contact information provided with your product or visit the official Orient Electric websit pou detay sipò.

© 2023 Orient Electric. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.