Andonstar AD246SM-Plus

Andonstar AD246SM-Plus Digital Microscope User Manual

Model: AD246SM-Plus

1. Entwodiksyon

This manual provides detailed instructions for the setup, operation, maintenance, and troubleshooting of your Andonstar AD246SM-Plus Digital Microscope. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage.

2. Pake kontni

Verifye ke tout atik ki nan lis anba a yo enkli nan pakè ou a:

  • Mikwoskòp x1
  • Metal stand x1
  • Extension Base x1
  • Tool holder x1
  • Soldering Clamp x1
  • Soldering mat x1
  • Lens A x1 (18X-720X)
  • Lens D x1 (1800X-2040X)
  • Lens L x1 (60X-240X)
  • USB kab x1
  • Switch cable x1
  • HDMI kab x1
  • Remote kontwòl x1
  • Slide holder x1
  • Slides kit x5
  • Observation box x1
  • Pensèt x1
  • 32G Micro SD card x1
  • Enstriksyon x1
Andonstar AD246SM-Plus Digital Microscope package contents

Image: All components included in the Andonstar AD246SM-Plus Digital Microscope package, laid out for inspection.

3. Enstriksyon Enstalasyon

3.1 Assembling the Stand and Workstation

  1. Place the main metal stand base on a stable surface.
  2. Attach the extension base components to the main stand base to create a larger workspace. Ensure they are securely interlocked.
  3. Mount the flexible helping hands with clamps onto the designated slots on the extension base. Adjust their position as needed.
  4. Install the tool holder bar onto the main stand's vertical pole.
  5. Place the soldering mat in the center of the extended base.
Assembled Andonstar AD246SM-Plus microscope workstation with helping hands and tool holder

Image: The fully assembled workstation of the Andonstar AD246SM-Plus microscope, showing the extended base, helping hands, and tool holder.

Assembly steps for Andonstar AD246SM-Plus microscope stand and base

Image: A visual guide illustrating the step-by-step assembly process for the microscope stand and its extended base components.

3.2 Attaching the Microscope Unit

  1. Carefully attach the microscope unit to the adjustable holder on the vertical pole of the stand.
  2. Tighten the securing screws to ensure the microscope is firmly in place.
  3. Connect the flexible LED lights to the stand and position them to illuminate the working area.
Andonstar AD246SM-Plus microscope with flexible LED lights attached to the stand

Image: The microscope unit mounted on its stand, with the flexible LED lights positioned for optimal illumination of the observation area.

3.3 Limen ak Premye Koneksyon

  1. Connect the power adapter to the microscope and a power outlet.
  2. Peze bouton pouvwa a pou limen mikwoskòp la.
  3. Pou pi gwo viewing, connect the microscope to an external display (monitor or TV) using the provided HDMI cable or to a PC via USB.
Andonstar AD246SM-Plus microscope connected to a large monitor via HDMI

Image: The Andonstar AD246SM-Plus microscope displaying its view on a large external monitor via HDMI connection, illustrating the dual-screen capability.

Video: This video demonstrates the assembly process of the Andonstar AD246SM-Plus digital microscope, including attaching the base, helping hands, and the microscope unit itself. It also shows the microscope in operation with different lenses.

4. Operasyon Enstriksyon

4.1 Lens Selection and Usage

The AD246SM-Plus comes with three interchangeable lenses, each designed for specific observation distances and magnification ranges:

  • Lens A (18X-720X): Ideal for observing larger objects such as coins, stamps, circuit boards, and stones. Observation distance: 12mm-320mm.
  • Lens L (60X-240X): Suitable for PCB/SMD soldering and general circuit board observation. Observation distance: 90mm-300mm.
  • Lens D (1800X-2040X): Designed for microscopic slides and very fine details. Observation distance: 4mm-5mm.

To change a lens, gently twist the current lens counter-clockwise to remove it, then align the new lens and twist clockwise until secure.

Andonstar AD246SM-Plus microscope with Lens A, showing a coin magnified

Image: Microscope with Lens A, demonstrating its use for magnifying a coin, suitable for larger objects.

Andonstar AD246SM-Plus microscope with Lens L, showing a circuit board magnified

Image: Microscope with Lens L, showing a magnified view of a circuit board, ideal for soldering tasks.

Andonstar AD246SM-Plus microscope with Lens D, showing a microscopic slide magnified

Image: Microscope with Lens D, displaying a highly magnified view of a microscopic slide, for very fine details.

4.2 Focusing and Magnification Adjustment

Use the focus knob on the microscope body to achieve a clear image. Adjust the distance between the lens and the object by moving the microscope unit up or down on the stand for optimal magnification and clarity.

Andonstar AD246SM-Plus microscope showing focus knob and object distance adjustment

Imaj: Gwo plan view of the microscope's focus knob and the mechanism for adjusting the object distance, crucial for clear magnification.

4.3 LED Lighting and Remote Control

The built-in 8 LED lights provide adjustable brightness and lighting angles. Use the remote control to capture images and record videos without disturbing the microscope, ensuring stable and clear results.

5. Antretyen

  • Netwayaj Lantiy: Use a soft, lint-free cloth and lens cleaning solution to clean the lenses. Avoid abrasive materials.
  • Netwayaj jeneral: Siye kò mikwoskòp la ak sipò a avèk yon twal sèk oswa yon ti kras mouye.amp twal. Pa sèvi ak pwodwi chimik piman bouk.
  • Depo: Store the microscope in a dry, dust-free environment when not in use.
  • Soldering Mat: The silicone soldering mat is resistant to heat, dirt, and oil. Clean it regularly to maintain its protective properties.

NAN. Depanaj

PwoblèmKòz posibSolisyon
Pa gen imaj sou ekran anPower not connected; Microscope not turned on; HDMI/USB cable loose or faulty.Check power connection; Press power button; Reconnect or replace cables.
Imaj floueIncorrect focus; Wrong lens for object distance; Object too far/close.Adjust focus knob; Select appropriate lens (A, L, or D); Adjust microscope height.
Ekran an ap tranble oswa imaj ki pa stabLoose cable connection; Power supply issue; Interference.Ensure all cables are securely connected; Try a different power outlet; Minimize electronic interference.
Remote kontwòl pa travayBatteries depleted; Obstruction between remote and microscope.Replace remote control batteries; Ensure clear line of sight to the microscope's IR receiver.

7. Espesifikasyon

  • Modèl: AD246SM-Plus (SXWL-246S-M-Plus)
  • Rezolisyon videyo: Ultra HD 2880x2160 24fps; Full HD 1920x1080 60fps/30fps; HD 1280x720 120fps
  • Agrandisman: Up to 2000X (with Lens D)
  • Lenses Included:
    • Lens A: 18X-720X (Object distance: 12mm-320mm)
    • Lens L: 60X-240X (Object distance: 90mm-300mm)
    • Lens D: 1800X-2040X (Object distance: 4mm-5mm)
  • Ekspozisyon: Integrated screen, supports HDMI output for larger field of view, USB output for PC connection.
  • Ekleraj: 8 reglabl limyè dirije
  • Kanpe: Upgraded Plus Stand with Extension Base (30cm x 40cm x 33cm)
  • Karakteristik adisyonèl: Soldering helping hands, tool holder, 100 grids compartment screw box, silicone soldering mat, IR remote control, 32G Micro SD card.
  • Pwa atik: 7.39 liv
  • Dimansyon pake: 17.5 x 10.8 x 6 pous
  • Manifakti: Andonstar
  • Koulè: Nwa
  • Materyèl: Metal

8. Garanti ak sipò

For warranty information and technical support, please refer to the official Andonstar websit la oubyen kontakte sèvis kliyan yo dirèkteman. Kenbe resi acha w la pou reklamasyon garanti.

Ou ka vizite a Andonstar Store on Amazon pou plis enfòmasyon sou pwodwi a ak resous sipò.

© 2024 Andonstar. Tout dwa rezève.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.