1. Entwodiksyon
The UNI-T UT60S is a smart, true RMS digital multimeter designed for accurate and reliable electrical measurements. Featuring 9999 counts, this device can measure AC/DC voltage, AC/DC current, resistance, diode, capacitance, temperature, and frequency. Its fully automatic anti-burn intelligent design helps prevent operational errors and device damage, making it suitable for both professional technicians and everyday users.

Figi 1: Devan view of the UNI-T UT60S Digital Multimeter.
2. Enfòmasyon sou Sekirite
Always adhere to safety precautions when using the multimeter. Failure to do so may result in electric shock, injury, or damage to the meter or equipment under test.
- Li Manyèl la: Before use, thoroughly read and understand all instructions and safety warnings in this manual.
- Rated Voltage: Pa aplike plis pase rated voltage, as marked on the meter, between terminals or between any terminal and earth ground. The UT60S is capable of withstanding a maximum overvoltage impulse of 1000V.
- Enspekte anvan w itilize: Anvan chak itilizasyon, enspekte mèt la, fil tès yo ak akseswa yo pou wè si yo domaje. Pa sèvi ak li si li domaje.
- Proper Terminals: Ensure test leads are connected to the correct input terminals for the measurement function selected.
- De-energizasyon sikwi: Always de-energize the circuit and discharge all high-voltage capacitors before performing resistance, continuity, diode, or capacitance measurements.
- Live Circuit Work: When working on live circuits, work alone as little as possible, and ensure another person is present to provide assistance if needed.
- Pwoteksyon Surkouran: The meter features overcurrent alarms and protection functions. Do not exceed the maximum current ratings for the input terminals.
- Kondisyon anviwònman: Use the meter only as specified in this manual. Do not use the meter in explosive gas, vapor, or dusty environments.
- Ekipman Pwoteksyon Pèsonèl: Toujou mete ekipman pwoteksyon pèsonèl (PPE) ki apwopriye, tankou linèt sekirite ak gan izole, lè w ap travay ak sikui elektrik.
3. Pwodwi Features
The UNI-T UT60S Digital Multimeter offers a range of features for versatile and safe electrical testing:
- Ekspozisyon 9999 konte: Provides high-resolution measurements for precision.
- Mezi vre RMS: Ensures accurate readings for non-sinusoidal waveforms.
- Fully Automatic Anti-Burn Design: Intelligent protection against operational errors and potential device damage.
- Wide Measurement Capabilities: Mezi AC/DC voltage (up to 1000V), AC/DC current, resistance, diode, capacitance, temperature, and frequency.
- Large LCD Screen with Dual Display: Allows simultaneous display of AC voltage and frequency, enhancing readability.
- Full Button Design: Offers intuitive control and automatic recognition of current input jacks.
- Fast ADC (Analog to Digital Converter): Provides rapid measurement updates (3 times/second).
- Misoperation Protection: Capable of withstanding a maximum overvoltage impulse of 1000V, with overvoltage and overcurrent alarms.
- NCV (Vol ki pa gen kontaktage) Function: Detekte AC voltage without physical contact, featuring audible and visual alarms for safety.
- Ekonomize pouvwa otomatik: Low power consumption (7mA during operation, 5uA in sleep state) and automatic backlight display in dark environments, extending battery life. Automatic shut-down feature.

Figure 2: The UT60S display with 9999 counts for precise readings.
4. Ki sa ki nan bwat la
Lè w ouvri pake a, ou ta dwe jwenn atik sa yo:
- Miltimèt dijital UNI-T UT60S
- Thermocouple (for temperature measurements)
- Multimeter Test Leads (red and black)
- 1.5V AAA Batteries (pre-installed or included separately)

Figure 3: Contents of the UNI-T UT60S package, including the multimeter, test leads, and thermocouple.
5. Enstalasyon
5.1. Enstalasyon batri
The UT60S typically uses 1.5V AAA batteries. To install or replace batteries:
- Asire w ke miltimèt la etenn epi fil tès yo dekonekte.
- Jwenn konpatiman pil la sou dèyè mèt la.
- Sèvi ak yon tournevis pou ouvri kouvèti konpatiman batri a.
- Insert the AAA batteries, observing correct polarity (+ and -).
- Ranplase kouvèti lòj batri a epi an sekirite li ak vis la.

Figi 4: Dèyè view of the UT60S, indicating the battery compartment location.
5.2. Konekte fil tès yo
Connect the test leads to the appropriate input terminals:
- The black test lead (common) should always be connected to the COM tèminal.
- Pou voltage, resistance, capacitance, frequency, diode, and continuity measurements, connect the red test lead to the VΩHzCAP tèminal.
- For current measurements (mA/A), connect the red test lead to the mA/A tèminal.
- Pou mikwoampere current measurements (μA), connect the red test lead to the μA tèminal.

Figure 5: Input terminals of the UT60S for connecting test leads.
6. Operasyon Enstriksyon
The UT60S features a full button design for selecting measurement functions. The meter's intelligent anti-burn design automatically recognizes the input jack and selected function.
6.1. Power On/Off
Peze a POUVWA button to turn the meter on or off. The meter will automatically shut down after a period of inactivity to save battery life.
6.2. Auto Mode
In Auto mode, the meter automatically identifies the measurement type (voltage, resistance, continuity) and selects the appropriate range. This simplifies operation for general troubleshooting.
6.3. Mezire Volim AC/DCtage
Pou mezire voltage:
- Konekte plon tès nwa a nan COM tèminal ak tès wouj la mennen nan la VΩHzCAP tèminal.
- Peze a V~ / Hz button to select AC voltage measurement, or the V= / NCV button for DC voltage. The meter may automatically select the correct mode in Auto range.
- Konekte sond tès yo atravè sikwi a oswa konpozan ki pral mezire a.
- Li voltage value on the display. For AC voltage, the frequency may also be displayed simultaneously.

Figure 6: Measuring AC voltage and frequency with the UT60S.
6.4. Measuring AC/DC Current
Pou mezire aktyèl:
- ENPÒTAN: To measure current, the meter must be connected in series with the circuit. Always turn off power to the circuit before connecting the meter.
- Konekte plon tès nwa a nan COM tèminal.
- For current up to 10A, connect the red test lead to the mA/A terminal. For microampere current, connect to the μA tèminal.
- Peze a ACA/DCA button to select AC or DC current measurement.
- Break the circuit and connect the test leads in series with the load.
- Mete kouran nan sikwi a epi li valè aktyèl la sou ekran an.
6.5. Measuring Resistance, Diode, and Continuity
To measure resistance, diode, or continuity:
- Ensure the circuit is de-energized and capacitors are discharged.
- Konekte plon tès nwa a nan COM tèminal ak tès wouj la mennen nan la VΩHzCAP tèminal.
- Peze a Ω→+ button to cycle through resistance, diode, and continuity functions.
- Konekte sond tès yo atravè konpozan an.
- Read the measurement. For continuity, an audible buzzer will sound if continuity is detected.
6.6. Measuring Capacitance
Pou mezire kapasite:
- Asire w ke kondansateur a dechaje nèt anvan ou fè tès la.
- Konekte plon tès nwa a nan COM tèminal ak tès wouj la mennen nan la VΩHzCAP tèminal.
- Peze a mV~°C°F button to select temperature measurement.
- Konekte sond tès yo atravè tèminal kondansateur yo.
- Li valè a kapasite sou ekspozisyon an.

Figure 7: The UT60S performing a capacitance measurement.
6.7. Mezire Tanperati
Pou mezire tanperati:
- Connect the thermocouple to the appropriate input terminals (usually the VΩHzCAP epi COM terminals, or dedicated temperature inputs if available).
- Peze a mV~°C°F button to select temperature measurement.
- Place the thermocouple probe at the point where temperature needs to be measured.
- Read the temperature value on the display in Celsius or Fahrenheit.
6.8. NCV (Non-Contact Voltage) Fonksyon
The NCV function allows detection of AC voltage san kontak dirèk ak kondiktè yo.
- Peze a V= / NCV button to activate the NCV function.
- Move the top of the meter close to the conductor or outlet.
- The meter will provide an audible alarm and visual indication (flashing light) if AC voltage is detected. The intensity of the alarm and light may vary with voltage fòs.

Figure 8: Using the NCV function to detect live AC voltage.
6.9. Done kenbe
Peze a KENBE bouton an pou bloke lekti aktyèl la sou ekran an. Peze l ankò pou lage fonksyon kenbe a.
6.10. Range Selection
While the meter typically operates in Auto range, you can manually select a range by pressing the NIVO button. This can be useful for specific applications or to speed up measurements in stable conditions. Press and hold the NIVO button to return to Auto range.
6.11. USB Communication (if applicable)
The UT60S series may support USB communication for data logging and analysis on a computer. If your model includes this feature, connect the meter to your computer using the provided USB cable and install the UNI-T software. Refer to the software manual for detailed instructions.
Video 1: Demonstration of features like NCV, LoZ, and USB communication on a UNI-T UT161 series multimeter. The UT60S shares similar functionalities.
7. Antretyen
7.1. Netwayaj
Siye bwat mèt la ak piblisiteamp twal ak yon savon dou. Pa sèvi ak pwodui abrazif oswa solvan. Asire w ke mèt la byen sèk anvan w itilize li.
7.2. Ranplasman batri
Ranplase pil yo lè endikatè pil ki fèb la parèt sou ekran an. Gade Seksyon 5.1 pou enstriksyon enstalasyon pil yo.
7.3. Ranplasman Fuse
If the current measurement function stops working, the fuse may need replacement. Refer to the full user manual for specific fuse ratings and replacement procedures. Always use fuses with the specified voltage ak evalyasyon aktyèl yo.
NAN. Depanaj
If you encounter issues with your UNI-T UT60S, try the following basic troubleshooting steps:
- Pa gen ekspozisyon/Limen: Tcheke enstalasyon pil yo epi asire w pil yo pa fin itilize. Ranplase yo si sa nesesè.
- Lekti ki pa kòrèk: Verify that the test leads are correctly connected to the appropriate terminals for the selected function. Ensure the function dial is set correctly. Check for damaged test leads.
- Mezi aktyèl la pa fonksyone: Check the fuse. If blown, replace it with a fuse of the correct rating. Ensure the meter is connected in series with the circuit.
- "OL" oswa Endikasyon Surcharge: This indicates that the measured value is outside the selected range or the maximum capability of the meter. Try selecting a higher range (if in manual range mode) or ensure the component is within the meter's specifications.
- NCV pa detekte: Ensure the NCV function is activated and the meter is brought close enough to the AC voltage sous.
For more complex issues, refer to the detailed troubleshooting section in the complete user manual or contact UNI-T customer support.
9. Espesifikasyon
Key specifications for the UNI-T UT60S Digital Multimeter:
| Karakteristik | Spesifikasyon |
|---|---|
| Montre konte | 9999 |
| Vrè RMS | Wi |
| AC / DC Voltage | Jiska 1000V |
| AC / DC Kouran | Up to 10A (mA/A terminals), Up to 1000μA (μA terminal) |
| Rezistans | 0.1Ω - 40MΩ |
| Kapasite | 1nF - 4000μF |
| Tanperati | Yes (with thermocouple) |
| Frekans | Wi |
| Tès dyòd | Wi |
| Tès kontinwite | Wi |
| NCV (Vol ki pa gen kontaktage) | Wi |
| Sous pouvwa | Battery Powered (1.5V AAA batteries) |
| Pwa atik | 370 gram |
| Konfòmite Sekirite | UL 61010-1, IEC 61010-2-030, CAT III 1000V, CAT II 600V |
10. Garanti ak sipò
UNI-T provides customer support for their products. If you encounter any problems during use, please contact UNI-T customer service directly via email. They offer 7/24 1-to-1 user support to address your concerns promptly.
For specific warranty details, please refer to the warranty card included with your product or visit the official UNI-T websit.