1. Entwodiksyon
This manual provides essential information for the safe and efficient operation of your PowerWalker VFI 1000 AT FR Online Uninterruptible Power Supply (UPS). The VFI AT series utilizes double-conversion technology to provide reliable power protection for critical devices. Please read this manual thoroughly before installation and use, and retain it for future reference.
2. Enstriksyon Sekirite
WARNING: Failure to follow these safety instructions can result in fire, electric shock, serious injury, or death.
- Pa louvri UPS la.asing. Pa gen pyès ki ka sèvi ak men itilizatè a anndan an. Konfye tout antretyen bay pèsonèl sèvis kalifye.
- Do not connect appliances that could overload the UPS, such as hair dryers or vacuum cleaners.
- Ensure the UPS is connected to a properly grounded power outlet.
- Do not block ventilation openings. Maintain adequate clearance around the UPS for proper airflow.
- Evite enstale UPS la nan zòn ki gen twòp pousyè, imidite oswa tanperati ekstrèm.
- In case of emergency, press the OFF button and disconnect the UPS from the AC power source.
3. Pwodwi souview
The PowerWalker VFI 1000 AT FR UPS is designed to provide clean, stable power to your connected equipment. It features a user-friendly interface and various connectivity options.
3.1 Panèl devan

Figure 3.1: Front Panel of the UPS. This image shows the main display screen indicating input and output voltage, battery status, and load level. Below the screen are four control buttons: ON, OFF, ENTER, and ESC.
The front panel includes an LCD display that provides real-time information about the UPS status, such as input/output voltage, battery charge, and load level. Control buttons allow for easy navigation and configuration.
- Ekspozisyon LCD: Shows operational status and parameters.
- Bouton ON: Powers on the UPS.
- Bouton OFF: Powers off the UPS.
- ANTRE bouton: Konfime seleksyon yo oubyen antre nan meni yo.
- ESC bouton: Exits menus or cancels operations.
3.2 Panèl dèyè

Figure 3.2: Rear Panel of the UPS. This image displays the connectivity options including a serial port (DB9), cooling fan, multiple Type F outlets, a USB port, an EPO (Emergency Power Off) terminal, and the AC input socket.
The rear panel provides all necessary connections for input power, output to protected devices, and communication interfaces.
- Antre AC: Konekte UPS la ak ekipman pou pouvwa prensipal la.
- Sòti Sòti: Type F, Type E, or Type G outlets (depending on model) for connecting protected equipment.
- Pò USB: For communication with a computer and monitoring software.
- RS-232 Port (Serial): For advanced communication and monitoring.
- EPO (Emergency Power Off) Terminal: For remote emergency shutdown.
- Intelligent Slot: For optional communication cards (e.g., SNMP card).
- Konektè pake batri ekstèn: For connecting optional external battery packs to extend backup time.
4. Enstalasyon
4.1 Debalaj ak enspeksyon
Carefully unpack the UPS and inspect it for any shipping damage. If any damage is found, do not install the unit and contact your dealer.
4.2 Plasman
Place the UPS in a clean, dry, and well-ventilated area. Ensure sufficient clearance (at least 20 cm) around the unit for proper heat dissipation. Avoid direct sunlight, heat sources, and excessive moisture.
4.3 Premye chaj
Before initial use, connect the UPS to a standard AC power outlet for at least 8 hours to ensure the internal batteries are fully charged. The UPS will charge its batteries whether it is turned ON or OFF.
4.4 Konekte Ekipman
- Connect your critical equipment (computers, monitors, network devices) to the output sockets on the rear panel of the UPS.
- Connect the UPS power cord to a grounded AC power outlet.
- (Optional) Connect the USB or RS-232 cable from the UPS to your computer for monitoring and management.
- (Optional) If using external battery packs, connect them according to their specific instructions to the designated connector on the UPS.
5. Fonksyonman UPS la
5.1 Turning On the UPS
Peze epi kenbe la ON button on the front panel for approximately 2 seconds until you hear a beep and the LCD display illuminates. The UPS will perform a self-test and then enter normal operating mode.
5.2 Turning Off the UPS
To turn off the UPS, press and hold the OFF button for approximately 2 seconds until the LCD display turns off. Ensure all connected equipment is properly shut down before turning off the UPS.
5.3 Ekran LCD ak Navigasyon
The LCD display provides various operational parameters. Use the ANTRE epi ESC buttons to navigate through menus and view different information screens. The display automatically darkens after a period of inactivity and can be woken up with a single button press.
5.4 Remote Shutdown (RPO)
The UPS supports Remote Power Off (RPO) functionality. Connect an external switch to the EPO terminal on the rear panel. Activating this switch will immediately shut down the UPS and connected equipment. Refer to the wiring diagram in the advanced user manual for proper connection.
6. Antretyen
6.1 Swen Batri
The UPS contains internal lithium batteries. To maximize battery life:
- Keep the UPS connected to AC power to keep batteries charged.
- Evite estoke UPS la nan tanperati ekstrèm.
- Perform a battery calibration (if available via software) or a full discharge/recharge cycle every 3-6 months.
- Replace batteries when their capacity significantly degrades. Battery replacement should only be performed by qualified personnel.
6.2 Netwayaj
Netwaye deyò UPS la avèk yon twal mou epi sèk. Pa sèvi ak pwodui netwayaj likid oswa ayewosòl. Asire w ke ouvèti vantilasyon yo pa gen pousyè ak debri.
6.3 Depo
If storing the UPS for an extended period, ensure the batteries are fully charged. Recharge the batteries every three months to prevent permanent damage.
NAN. Depanaj
This section provides solutions to common issues you may encounter with your UPS. If the problem persists, contact technical support.
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| UPS la pa limen. | No AC input power; Low battery charge. | Check AC power connection; Allow UPS to charge for 8 hours. |
| UPS la ap bipe kontinyèlman. | Overload; Low battery; Fault condition. | Reduce connected load; Allow batteries to charge; Check LCD for error codes. |
| Tan backup kout. | Batteries not fully charged; Batteries reaching end of life. | Ensure full charge; Consider battery replacement. |
| Connected equipment not receiving power. | UPS is off; Output sockets not enabled; UPS in fault mode. | Turn on UPS; Check LCD for status; Consult manual for output settings. |
8. Espesifikasyon
| Karakteristik | Detay |
|---|---|
| Modèl | VFI 1000 AT FR (Model Number: 10122183) |
| Mak | PowerWalker |
| Kapasite pouvwa sòti | 900W |
| Antre Voltage | 220V (Wide input voltage ranje) |
| Kalite batri | Lityòm |
| Sòti Sockets | Type F, Type E, Type G (various versions available) |
| Pò kominikasyon | USB (HID support), RS-232, Intelligent Slot |
| Dimansyon (H x W x P) | 50 x 10 x 48 cm (apeprè) |
| Pwa | 2 Kilogram |
| Karakteristik espesyal | Double-conversion online technology, Generator compatible, RPO, External battery pack support, Automatically darkening LCD. |
9. Garanti ak sipò
The PowerWalker VFI 1000 AT FR UPS is covered by a standard manufacturer's warranty. Please refer to the warranty card included with your product or visit the official PowerWalker websit la pou wè tèm ak kondisyon garanti detaye yo.
For technical support, troubleshooting assistance beyond this manual, or spare parts inquiries, please contact your local dealer or PowerWalker customer service. The EU Spare Part Availability Duration is 2 Years.