ECOELER YM2511

Manyèl Enstriksyon pou Entèriptè Mouvman Okipasyon Plafon ECOELER YM2511

Modèl: YM2511

1. Entwodiksyon ak souview

The ECOELER YM2511 Ceiling Occupancy Motion Sensor Switch is designed to automatically control lighting based on occupancy detection. Utilizing Passive Infrared (PIR) technology, it senses moving objects within its detection zone to turn lights ON and OFF, promoting energy efficiency.

This sensor features adjustable settings for time delay, sensitivity, and ambient light levels, allowing customization for various environments. It offers a 360-degree detection range, making it suitable for a wide array of applications including hallways, bathrooms, storage areas, and commercial spaces.

ECOELER YM2511 Ceiling Occupancy Motion Sensor Switch

Figure 1: ECOELER YM2511 Ceiling Occupancy Motion Sensor Switch. This image displays the compact, white square-shaped sensor unit with its integrated PIR lens and wiring conduit.

2. Enfòmasyon sou Sekirite

AVÈTISMAN: Risk pou chòk elektrik. Improper installation can lead to serious injury or death. Always turn off power at the circuit breaker before installation or servicing. Installation should be performed by a qualified electrician in accordance with all national and local electrical codes.

  • Ensure the power supply is disconnected before handling any wiring.
  • Verify voltage compatibility (120/277VAC) before installation.
  • Sèvi ak kondiktè kwiv sèlman.
  • Connect to supply connections rated for at least 75°C.
  • Pa enstale li nan kote ki gen twòp vibrasyon oswa tanperati ekstrèm.

3. Pake kontni

The ECOELER YM2511 package includes:

  • ECOELER YM2511 Occupancy Sensor
  • Mounting accessories (e.g., wire nuts)
  • Manyèl itilizatè (dokiman sa a)
Wire nuts and mounting accessories

Figure 2: Included wire nuts for electrical connections. This image shows three orange wire nuts, typically used for securing electrical connections during installation.

4. Espesifikasyon

KarakteristikSpesifikasyon
Nimewo ModèlYM2511
Voltage120 / 277VAC, 60Hz
Chaj Maksimòm (Enkandesan)120VAC: 600W
Max Load (Fluorescent/LED)120VAC: 800W, 277VAC: 1200W
Teknoloji deteksyonEnfrawouj pasif (PIR)
Ang deteksyon360 degre
Ranje deteksyonUp to 24 feet (7.3 meters) diameter when mounted at 20 feet height
Reglabl Tan Reta15 segonn a 30 minit
Sansiblite reglabl20% a 100%
Nivo limyè reglablYes (Daylight Harvesting)
Tanperati Fonksyònman0°C a 55°C (32°F a 131°F)
Dimansyon pwodwi3.97 x 1.37 x 3.14 pous
Kalite aliyeCeiling Mount (Fixture Mount)
SètifikasyonUL, FCC Approved
Dimensional drawing of ECOELER YM2511 sensor

Figure 3: Dimensional drawing of the ECOELER YM2511 sensor. This diagram provides precise measurements of the sensor unit, including its length, width, and height, along with the diameter of the threaded conduit.

5. Enstalasyon

5.1 Lis Enstriksyon Pre-Enstalasyon an

  • Fèmen kouran nan disjoncteurs a.
  • Ensure you have the necessary tools (screwdriver, wire strippers, electrical tape).
  • Confirm the mounting location is suitable for a ceiling-mounted sensor, free from obstructions that might block the detection field.

5.2 Enstriksyon fil elektrik

The ECOELER YM2511 requires a neutral wire for operation. Follow the wiring diagram provided with your product or consult a qualified electrician. Typical wiring involves connecting the sensor's wires to the building's electrical system (Line, Load, Neutral, Ground).

  • Fil nwa: Liy (cho)
  • Fil blan: net
  • Fil wouj: Load (to light fixture)
  • Fil kwiv vèt/toutouni: Ground (if applicable)

Sere tout koneksyon yo ak boulon fil elektrik ak tep elektrik. Asire w pa gen okenn fil elektrik ki pa kouvri.

5.3 Montaj

Mount the sensor to a standard ceiling junction box or directly to a high bay fixture. The sensor is designed for optimal 360-degree detection when installed at a height of approximately 20 feet, providing a detection range of up to 24 feet in diameter.

Diagram showing 360-degree PIR motion detection range

Figure 4: 360-degree PIR motion detection pattern. This diagram illustrates the circular detection field of the sensor, showing how it covers a wide area around its mounting point, with a person icon indicating motion detection.

6. Operasyon ak Anviwònman

After installation and restoring power, the sensor will enter a warm-up period. The integrated LED indicator will flash during motion detection. The sensor features three adjustable dials for customization:

Adjustment dials for Time, Sense, and Light on the ECOELER YM2511 sensor

Figure 5: Adjustment dials for Time, Sense, and Light. This image shows the three rotary dials on the sensor's face, labeled for adjusting time delay, sensitivity, and ambient light detection.

  1. TIME (1): Controls how long the light or fan remains ON after no motion is detected. Adjustable from 15 seconds to 30 minutes.
    • Rotate clockwise for longer delay.
    • Rotate counter-clockwise for shorter delay.
  2. SENSE (2): Adjusts the sensitivity of the motion detection. This helps prevent unwanted activations from minor movements or distant traffic. Adjustable from 20% to 100%.
    • Rotate clockwise for higher sensitivity (detects smaller movements, wider range).
    • Rotate counter-clockwise for lower sensitivity (detects larger movements, shorter range).
  3. LIMYÈ (3): Prevents the sensor from automatically turning ON lights or fans if there is sufficient ambient lighting in the area (Daylight Harvesting).
    • Rotate clockwise to allow activation in brighter conditions.
    • Rotate counter-clockwise to only activate in darker conditions.

The sensor is compatible with various lighting types:

Universal compatibility with Incandescent, CFL, and LED lamps

Figure 6: Universal compatibility with various lamp types. This graphic shows icons for Incandescent, CFL, and LED lamps, indicating the sensor's broad compatibility with different lighting technologies and their respective wattage evalyasyon.

NAN. Depanaj

PwoblèmKòz posibSolisyon
Lights do not turn ON with motion.
  • Pa gen kouran ki rive nan detèktè a.
  • Kòrèk fil elektrik.
  • Light level setting too high (Daylight Harvesting active).
  • Sensitivity setting too low.
  • Motion outside detection range.
  • Tcheke koneksyon disjonktè a ak fil elektrik yo.
  • Verify wiring against instructions.
  • Adjust the LIGHT dial counter-clockwise.
  • Increase the SENSE dial setting.
  • Ensure motion occurs within the 360-degree detection zone.
Lights turn OFF too quickly.
  • Time delay setting too short.
  • Sensor not detecting continuous motion.
  • Increase the TIME dial setting.
  • Increase the SENSE dial setting or reposition the sensor for better coverage.
Lights turn ON without apparent motion.
  • Sensitivity setting too high.
  • Heat sources or air currents causing false triggers.
  • Decrease the SENSE dial setting.
  • Relocate the sensor away from HVAC vents, windows, or other heat sources.

8. Antretyen

The ECOELER YM2511 sensor requires minimal maintenance. Periodically, gently wipe the sensor lens with a soft, dry cloth to remove dust or debris that may obstruct detection. Do not use abrasive cleaners or solvents.

Regularly inspect wiring connections for any signs of wear or damage. If any issues are found, disconnect power and consult a qualified electrician.

9. Garanti ak sipò

ECOELER products are designed for reliability and performance. For any questions regarding your ECOELER YM2511 Motion Sensor Switch, please contact our customer service. We are committed to providing support and will respond to inquiries within 24 hours.

Tanpri gade dokiman acha ou a pou kondisyon ak tèm garanti espesifik yo.

© 2026 ECOELER. Tout dwa rezève.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.