sinocare Safe-Accu2
Manyèl Itilizatè Glucometer Sinocare Safe-Accu2 Glucometer
Model: Safe-Accu2
1. Entwodiksyon
This user manual provides essential information for the safe and effective operation of the Sinocare Safe-Accu2 Blood Glucose Monitoring System. Please read this manual thoroughly before using the device for the first time and keep it for future reference. This system is intended for in vitro diagnostic use by people with diabetes at home and by healthcare professionals in clinical settings as an aid in monitoring the effectiveness of diabetes control.
2. Pwodwi souview
2.1. Pake kontni
The Sinocare Safe-Accu2 kit includes the following components:
- 1 x Safe-Accu2 Blood Glucose Monitor
- 1 x Lancing Aparèy
- 100 x Twist Lancets
- 100 x Vial-packing Test Strips
- 1 x pòtab sak
- 1 x manyèl itilizatè

Image 2.1: Complete Sinocare Safe-Accu2 Blood Glucose Monitoring System kit, including the meter, test strips, lancets, lancing device, and carrying case.
2.2. Karakteristik kle
- No Coding Required: Simplifies the testing process.
- Fast Test Results: Provides results in approximately 10 seconds.
- Ti san Sample: Requires only 0.6µL of blood.
- Endikasyon limyè: Red and green indicator lights provide visual cues for blood glucose levels (green for normal, red for abnormal).
- Fonksyon memwa: Stores up to 200 test results and calculates 7/14/30-day averages.
- FAD-GDH System: Utilizes FAD-GDH enzyme technology to minimize interference from oxygen and xylose, ensuring accurate results.

Image 2.2: Visual representation of the Sinocare Safe-Accu2's key features, including light indication, SOD chip, 200 test memories, 10-second test time, and 0.6µL blood sample requirement.

Image 2.3: Diagram illustrating the components of the Safe-Accu2 meter, including the strip ejection button, blood sampling segment, test strip port, indicator lights, battery door, and control buttons.
3. Enstalasyon
3.1. Enstalasyon batri
The Safe-Accu2 meter uses alkaline batteries. To install or replace batteries:
- Locate the battery compartment door on the back of the meter (refer to Image 2.3).
- Louvri pòt lòj batri a.
- Mete nouvo pil, asire polarite kòrèk (+/-).
- Fèmen pòt konpatiman batri a byen fèm.
3.2. Mete Dat ak Lè
Refer to the full user manual for detailed instructions on setting the date and time on your Safe-Accu2 meter. This ensures accurate record-keeping of your test results.
4. Operating Instructions: Performing a Blood Glucose Test
Follow these steps to perform a blood glucose test using your Sinocare Safe-Accu2 system:
- Prepare Your Hands: Wash your hands thoroughly with warm, soapy water and dry them completely. This helps prevent infection and ensures an accurate sample.
- Prepare aparèy lansè a: Insert a new lancet into the lancing device and set the penetration depth.
- Mete bann tès la: Remove a test strip from its vial and immediately close the vial cap tightly. Insert the test strip into the meter's test strip port. The meter will turn on automatically.
- Jwenn san Sample: Prick the side of your fingertip with the lancing device. Gently squeeze your finger to form a small drop of blood.
- Aplike san Sample: Touch the tip of the test strip to the blood drop. The strip will draw the blood into the reaction area. Ensure the blood sample is sufficient (0.6µL). Do not smear the blood.
- Li rezilta yo: The meter will display your blood glucose result in approximately 10 seconds. Observe the indicator light: green for normal range, red for abnormal.
- Eject Strip: Use the strip ejection button to safely dispose of the used test strip.

Image 4.1: Step-by-step guide for performing a blood glucose test, from cleaning hands to obtaining and applying a blood sample, and finally reading the result.

Image 4.2: Important tips for blood sampling, showing correct blood volume and emphasizing the use of test strips within their valid time (six months after opening the vial).
5. Antretyen
5.1. Netwaye mèt la
To clean the exterior of your Safe-Accu2 meter, wipe it gently with a soft, damp cloth. Do not immerse the meter in water or use harsh cleaning agents. Ensure no liquid enters the test strip port.
5.2. Kondisyon Depo
Store the meter and test strips in a cool, dry place within the recommended temperature ranges.
- Meter Storage Temperature: 1°C a 30°C (34°F a 86°F)
- Test Strip Storage Temperature: 1°C a 30°C (34°F a 86°F)
- Operating Test Temperature: 10°C a 35°C (50°F a 95°F)
Always keep test strip vials tightly closed after removing a strip. Use test strips within six months of opening the vial and before the expiration date printed on the packaging.

Image 5.1: Information on recommended storage temperature, test temperature, and HCT (Hematocrit) range for the Safe-Accu2 system to ensure accurate readings.
NAN. Depanaj
If you encounter issues with your Safe-Accu2 meter, consider the following:
- Kontè a pa limen: Check if the batteries are correctly installed and have sufficient power. Replace batteries if necessary.
- Mesaj erè: Refer to the full user manual for a list of error codes and their corresponding solutions. Common issues include insufficient blood sample or expired/damaged test strips.
- Rezilta ki pa kòrèk: Ensure hands are clean and dry, the blood sample is adequate, and test strips are not expired. Verify that the meter and strips are stored within recommended temperature ranges.
- No Blood Drawn by Strip: Ensure the test strip is inserted correctly and the blood drop is large enough to be absorbed.
If problems persist, contact Sinocare customer support for assistance.
7. Espesifikasyon
| Spesifikasyon | Valè |
|---|---|
| Non modèl | Safe-Accu2 |
| Dimansyon pwodwi | 23.1 x 16.7 x 6.3 cm |
| Pwa pwodwi | 420 gram |
| Manifakti | sinocare |
| Peyi orijin | Lachin |
| Konpozisyon selil batri | Alkalin |
| Tan tès la | 10 segonn |
| San Sample Volim | 0.6µL |
| Kapasite memwa | 200 rezilta tès yo |
| UPC | 860011998532 |
| Tanperati Depo | 1°C - 30°C |
| Tanperati tès la | 10°C - 35°C |
| Gam HCT | 30% - 60% |
8. Garanti ak sipò
For information regarding warranty and returns, please refer to the purchase platform's policies. Generally, products can be returned within 30 days of receipt if you change your mind. For defective or damaged products, specific return policies apply.
For further assistance or technical support, please visit the official Sinocare websit la oubyen kontakte sèvis kliyan yo dirèkteman.