The T.I.P. Maxima 350 IPX DUO is a powerful and versatile combination submersible pump designed for various water drainage tasks. Its extendable pump base allows for quick conversion between a high-performance dirty water pump and a clean water pump with ultra-flat suction. This manual provides essential information for safe and efficient operation, setup, and maintenance of your pump.

T.I.P. Maxima 350 IPX DUO Dirty Water Pump

Image: The T.I.P. Maxima 350 IPX DUO pump, showcasing konsepsyon solid li yo ak konpozan li yo.

2. Enstriksyon Sekirite

Tanpri li epi konprann tout enstriksyon sekirite yo anvan ou itilize ponp lan. Si ou pa swiv enstriksyon sa yo, sa ka lakòz chòk elektrik, dife, blesi grav oswa domaj materyèl.

  • Toujou dekonekte ponp lan nan ekipman pou kouran an anvan ou fè nenpòt antretyen oswa netwayaj.
  • Ensure the power cable and plug are in perfect condition. Do not use if damaged.
  • The pump is designed for pumping water only. Do not use it for flammable, corrosive, or explosive liquids.
  • Do not operate the pump in swimming pools or areas where people are in the water.
  • Kenbe timoun ak moun ki pa otorize lwen zòn operasyon an.
  • Asire bon vantilasyon lè w ap travay nan espas fèmen.
  • The maximum liquid temperature for operation is 35 °C.

3. Pake kontni

Verifye ke tout atik yo prezan nan pakè a:

  • T.I.P. Maxima 350 IPX DUO Submersible Pump with connection cable
  • Connection elbow with union nut
  • Multi-dimensional connection piece
  • Manyèl enstriksyon

4. Enstalasyon

4.1 Konekte tiyo dechaj la

The pump features a 47.80 mm (1.5 inch external thread) pressure connection. Use the provided connection elbow and multi-dimensional connection piece to attach your discharge hose.

  • Opsyon 1: Hose with Ø 40 mm. Secure with a hose clamp.
  • Opsyon 2: Hose with 1 1/4" internal thread. Remove the upper part of the connector.
  • Opsyon 3: Hose with Ø 32 mm. Secure with a hose clamp.
  • Opsyon 4: Hose with 1" internal thread. Remove the upper part of the connector.
  • Opsyon 5: Hose with 1 1/2" internal thread. Use the supplied connection elbow.
Connection sizes for T.I.P. Maxima 350 IPX DUO pump

Image: Diagram showing various hose connection options and sizes for the pump.

Connection elbow for T.I.P. Maxima 350 IPX DUO pump

Image: The supplied connection elbow for attaching a 1 1/2" internal thread hose.

An optional C-Storz coupling can also be used for the discharge hose (not included).

4.2 Adjusting the Pump Base for Water Type

The Maxima 350 IPX DUO features an extendable pump base to switch between dirty water and clean water modes.

  • Mòd Dlo Sal: For water with particle sizes up to 30 mm. The pump base is extended, allowing for a residual water level of 35 mm.
  • Clean Water Mode (Flat Suction): For clear water with particle sizes up to 1 mm. The pump base is retracted, enabling an ultra-flat suction down to 1 mm residual water level.
T.I.P. Maxima 350 IPX DUO pump with extendable base

Image: The T.I.P. Maxima 350 IPX DUO pump, highlighting its extendable pump base for different water types.

T.I.P. Maxima 350 IPX DUO pump in dirty water

Image: The pump operating in dirty water, showing the water level at 125 mm for activation.

T.I.P. Maxima 350 IPX DUO pump with 35mm residual dirty water

Image: The pump after draining dirty water, showing a residual water level of 35 mm.

T.I.P. Maxima 350 IPX DUO pump in clean water

Image: The pump operating in clean water, showing the water level at 100 mm for activation.

T.I.P. Maxima 350 IPX DUO pump with 1mm residual clean water

Image: The pump after draining clean water, showing an ultra-flat residual water level of 1 mm.

T.I.P. Maxima 350 IPX DUO pump particle size

Image: Illustration of the maximum particle sizes the pump can handle: 1 mm for clear water and 30 mm for dirty water.

4.3 Ajisteman switch Flote

The pump is equipped with a variable adjustable float switch for automatic operation. The switch points depend on whether the pump is configured for clean or dirty water.

  • Mòd Dlo Pwòp: Switch-on point at 24 cm, switch-off point at 14 cm.
  • Mòd Dlo Sal: Switch-on point at 27.5 cm, switch-off point at 17.5 cm.
T.I.P. Maxima 350 IPX DUO clean water float switch settings

Image: Diagram illustrating the float switch activation and deactivation points for clean water pumping.

T.I.P. Maxima 350 IPX DUO dirty water float switch settings

Image: Diagram illustrating the float switch activation and deactivation points for dirty water pumping.

5. Fonksyonman Ponp lan

Once the pump is set up with the correct hose and pump base configuration for your application, plug it into a suitable power outlet (230V). The float switch will automatically activate the pump when the water level reaches the switch-on point and deactivate it when it drops to the switch-off point.

Ponp lan apwopriye pou:

  • Pumping and draining clear water.
  • Pumping dirty water with particle sizes up to 30 mm.
  • Dry drainage down to 1 mm.
  • Emergency dewatering during floods.
T.I.P. Maxima 350 IPX DUO pump in construction site and flooded basement

Image: The pump being used in a construction pit and for draining a flooded basement, demonstrating its versatility.

5.1 Koub Pèfòmans

The transport curve illustrates the relationship between the delivery head (Opvoerhoogte [m]) and the flow rate (Stroomsnelheid Q [m³/u]). This helps in understanding the pump's performance under different conditions.

T.I.P. Maxima 350 IPX DUO pump performance curve

Image: Graph showing the pump's performance curve, detailing flow rate versus head height.

5.2 Vortex Impeller

The pump is equipped with a vortex impeller, which helps prevent clogging and ensures low-maintenance operation, especially when handling dirty water.

T.I.P. Maxima 350 IPX DUO pump vortex impeller details

Imaj: Detaye view of the pump's components, including the vortex impeller designed to prevent clogging.

6. Antretyen

Regular maintenance ensures the longevity and optimal performance of your T.I.P. Maxima 350 IPX DUO pump.

  • Netwayaj: After each use, especially with dirty water, rinse the pump with clean water to remove any debris.
  • Enspeksyon: Periodically check the power cable, plug, and float switch for any signs of damage.
  • Depo: Store the pump in a dry, frost-free location when not in use for extended periods.
  • Tcheke Enpèlè: If performance drops, check the impeller for blockages or wear.

NAN. Depanaj

Si ou rankontre pwoblèm ak ponp ou a, gade etap depanaj komen sa yo:

PwoblèmKòz posibSolisyon
Ponp pa kòmanseNo power supply; Float switch not activated; Impeller blocked.Check power connection; Ensure water level is above switch-on point; Clean impeller.
Reduced pumping capacityHose kinked or blocked; Impeller partially blocked; Pump base clogged.Check and clear hose; Clean impeller and pump base.
Ponp kouri kontinyèlmanFloat switch stuck or faulty; Water level not dropping below switch-off point.Check float switch for obstructions; Ensure proper water drainage.

If the problem persists, contact T.I.P. customer support or a qualified technician.

8. Espesifikasyon

KarakteristikValè
ManifaktiT.I.P.
Nimewo Modèl30274
Dimansyon pwodwi16.9 x 19.8 x 39.1 cm
Pwa7 kg
MateryèlStainless Steel (Acier inoxydable)
Sous pouvwaFil elektrik
Voltage230 Volt
Wattage800 Watt
Pousantaj maksimòm koule20,000 lit pou chak èdtan
Maksimòm wotè tèt8 m
Pwofondè maksimòm Submersion7 m
Maksimòm gwosè patikil30 mm (dirty water) / 1 mm (clean water)
Minimum Suction Height35 mm (dirty water) / 1 mm (clean water)
Maksimòm Tanperati Mwayen35 °C
Longè kab koneksyon10 m, H07RN8-F
Koneksyon presyon47.80 mm (1.5 inch external thread)

9. Videyo pwodwi ofisyèl yo

Watch these official videos for additional guidance on using your T.I.P. pump.

T.I.P. Extrema 300/10 Pro Waste Water Submersible Pump

Video: This video demonstrates the features and operation of the T.I.P. Extrema 300/10 Pro, a similar waste water submersible pump, providing a visual guide to handling and usage.

10. Garanti ak sipò

T.I.P. provides high-quality and durable products. For any issues or questions regarding your Maxima 350 IPX DUO pump, please refer to the warranty information provided with your purchase or contact T.I.P. customer support.

T.I.P. offers a 10-year guarantee on the availability of spare parts, ensuring long-term support for your product.