DHC-96 mVdc Digital Voltmeter Shunt User Manual

Model: M22348. | Brand: Circutor

1. Entwodiksyon

The Circutor DHC-96 mVdc Digital Voltmeter Shunt (Model M22348.) is a sophisticated digital instrument panel designed for precise monitoring, regulation, and control of electrical variants and process signals. This device is capable of displaying measured electrical values or proportional values of process signals, making it suitable for a wide range of industrial and climate solar installations.

Karakteristik kle yo enkli:

  • Segondè presizyon nan mezi.
  • Programmable measurement input.
  • Integrated relay output for control and alarm functions.
  • Universal power supply compatibility (80-270 Vca/cc and 16-36 VCC).
  • Frontal IP 54 protection for enhanced durability.
  • Galvanic insulation between external circuits.
  • Self-configurable decimal point.
  • Designed for panel installation (96 x 49 mm).
Circutor DHC-96 mVdc Digital Voltmeter Shunt with red digital display showing '0.000 A' and control buttons below.

Figi 1: Devan view of the Circutor DHC-96 mVdc Digital Voltmeter Shunt, showing its digital display and control buttons.

2. Enstalasyon ak Enstalasyon

Proper installation is crucial for the optimal performance and longevity of your DHC-96 device. Ensure all power sources are disconnected before proceeding with installation.

2.1 Panel Mounting

  • Prepare a panel cutout with dimensions of 96 x 49 mm.
  • Insert the DHC-96 unit into the cutout from the front.
  • Secure the unit using the provided mounting clips or brackets from the rear of the panel. Ensure a snug fit to maintain the IP 54 frontal protection rating.

2.2 Koneksyon ekipman pou pouvwa

The DHC-96 supports a universal power supply. Connect the power source to the designated terminals on the rear of the unit.

  • For AC/DC power, connect to 80-270 Vca/cc terminals.
  • For DC power, connect to 16-36 VCC terminals.
  • Ensure correct polarity for DC connections.

2.3 Measurement Input Connection

Connect the signal source to the programmable measurement input terminals. Refer to the wiring diagram provided with your specific model for detailed connection points.

  • Pou voltage measurements, connect the voltage sous.
  • For current measurements, connect through a shunt or current transformer as appropriate for your application.
  • Ensure galvanic insulation between external circuits is maintained.

2.4 Koneksyon Sorti Relè

The DHC-96 features two output relays for control and alarm functions. Connect these relays to your external control systems or alarm indicators as required.

  • Identify the relay output terminals.
  • Wire the relays according to your application's control logic.
  • Configure alarm delays and interlocking settings via the device's menu.

3. Operasyon Enstriksyon

Once installed and powered, the DHC-96 is ready for operation. The front panel features a digital display and control buttons for configuration and monitoring.

3.1 Ekspozisyon souview

The digital display shows the measured electrical variant (e.g., voltage, current, frequency) or the proportional value of a process signal. The unit automatically adjusts the display based on the configured measurement type.

  • DC Systems: Kapab mezire volimtage, current, frequency, and other industrial process variables.
  • Modèl AC: Perform measurements in True Effective Value (TRMS).
  • Pwen Decimal: The decimal point is self-configurable to suit your measurement precision requirements.

3.2 Fonksyon bouton

The front panel buttons allow for navigation through menus, parameter configuration, and display adjustments. Specific button functions may vary slightly depending on the firmware version.

  • Flèch agoch/adwat (< / >): Typically used for navigating through menu options or adjusting values.
  • Flèch monte/desann ( / ): Itilize pou ogmanteasing/diminisyonasing values or selecting options.
  • Menu/Entre bouton: Used to access the main menu, confirm selections, or save settings.
  • Escape/Back Button: Used to exit a menu or cancel an operation.

3.3 Configuration and Programming

The DHC-96 allows for programming various parameters to suit specific application needs. This includes setting the measurement input type, configuring alarm thresholds, and defining relay behaviors.

  • Access the configuration menu by pressing the Menu/Enter button.
  • Navige nan opsyon meni yo lè l sèvi avèk bouton flèch yo.
  • Select the desired parameter to modify and adjust its value.
  • Sove chanjman yo anvan ou soti nan meni an.
  • Refer to the detailed programming guide (if available separately) for advanced configurations.

4. Antretyen

The DHC-96 is designed for reliable operation with minimal maintenance. Regular inspection and cleaning will help ensure its continued performance.

  • Netwayaj: Periodically clean the front panel with a soft, damp twal. Pa sèvi ak pwodui netwayaj abrazif oswa solvan, paske yo ka domaje ekran an oswa casing.
  • Enspeksyon: Regularly inspect the wiring connections for any signs of wear, corrosion, or looseness. Ensure the unit is securely mounted in its panel cutout.
  • Anviwònman: Ensure the operating environment remains within the specified temperature and humidity ranges to prevent damage. The IP 54 frontal protection helps against dust and splashing water, but the unit is not designed for immersion.
  • Pa gen okenn pati itilizatè yo ka fè sèvis: The DHC-96 contains no user-serviceable parts. Do not attempt to open the casing, paske sa ap anile garanti a epi li ka ekspoze ou a danje elektrik.

NAN. Depanaj

If you encounter issues with your DHC-96, refer to the following common troubleshooting steps. For problems not listed here, contact Circutor technical support.

  • Pa gen ekspozisyon/pouvwa:
    • Check the power supply connections to ensure they are secure and correctly wired.
    • Verify that the power source voltage is within the specified range (80-270 Vca/cc or 16-36 VCC).
    • Check for any tripped circuit breakers or blown fuses in the power circuit.
  • Lekti ki pa kòrèk:
    • Ensure the measurement input is correctly connected and the signal source is active.
    • Verify that the device's measurement input type is correctly configured in the settings to match your application (e.g., voltage, current, process signal).
    • Check for any external interference or noise affecting the signal.
    • Confirm the decimal point setting is appropriate for the expected values.
  • Relè pa aktive:
    • Check the relay output wiring for proper connection to the external control system.
    • Verify the alarm thresholds and relay logic are correctly configured in the device's settings.
    • Ensure the measured value has exceeded or fallen below the set alarm threshold.
    • Check for any configured alarm delays or interlocking conditions that might prevent immediate activation.

6. Espesifikasyon

AtribiValè
ManifaktiSikitè
Nimewo PatiM22348.
Nimewo Modèl AtikM22348.
Dimansyon pwodwi3.01 x 1.93 x 3.78 pous
Pwa atik7 ons
KoulèNwa
Stylesèk
Sous pouvwaElektrik
Kantite pake atik1
Batri obligatwa?Non
ASINB08WL8FMDB
Dat Premye Disponib15 out 2023

7. Garanti ak sipò

For detailed warranty information, please refer to the warranty card included with your product or visit the official Circutor websit. Tèm ak kondisyon garanti yo ka varye selon rejyon an ak pwodwi a.

For technical support, service, or inquiries regarding your DHC-96 mVdc Digital Voltmeter Shunt, please contact Circutor customer service or your authorized dealer. Provide your product model number (M22348.) and serial number (if applicable) when seeking support.

You can find more information and contact details on the official Circutor websit: www.circutor.com

© 2023 Circutor. All rights reserved. | Model: DHC-96 (M22348.)