Entwodiksyon
The PowerWalker VFI AT series is an online Uninterruptible Power Supply (UPS) system designed to provide reliable power protection for critical electronic devices. This manual provides essential information for the safe and efficient operation of your PowerWalker VFI 3000 AT UPS, model 10122182.
Enstriksyon Sekirite Enpòtan
Please read and follow all instructions carefully before installing, operating, or servicing the UPS. Keep this manual for future reference.
- UPS sa a gen volim danjere.tagPa eseye demonte aparèy la. Se sèlman pèsonèl kalifye ki dwe fè antretyen an.
- UPS la dwe konekte ak yon priz kouran AC ki gen koneksyon ak tè.
- Do not block ventilation openings. Ensure adequate airflow around the UPS.
- Pa enstale UPS la anba limyè solèy dirèk, toupre sous chalè, oswa nan anviwònman ki gen twòp pousyè, imidite, oswa sibstans koroziv.
- The internal batteries are not user-replaceable. Contact qualified service personnel for battery replacement.
- In case of fire, use a dry chemical fire extinguisher. Water can be dangerous.
Kontni pake
Verify that all items listed below are included in your package. If any items are missing or damaged, contact your dealer.
- PowerWalker VFI 3000 AT UPS Unit
- Manyèl Itilizatè (dokiman sa a)
- USB kominikasyon kab
- Pouvwa Antre Kab
- CD lojisyèl (si sa aplikab)
Pwodwi souview
Front Panel

Figi 1: Devan view of the PowerWalker VFI 3000 AT UPS. This image displays the main chassis, ventilation grilles, and the front control panel with its LCD screen and buttons.

Figi 2: Detaye view of the UPS front panel. The LCD screen shows input/output voltage and load status. Below the screen are control buttons: ON, OFF, ENTER, and ESC, used for navigating menus and controlling the unit.
The front panel features an LCD display that provides real-time information about the UPS status, including input/output voltage, battery level, and load capacity. Control buttons allow for navigation through the display menus and basic operation of the unit.
Panèl dèyè

Figi 3: Dèyè view of the PowerWalker VFI 3000 AT UPS. This panel includes multiple Type F earthing contact outlets for connecting protected devices, cooling fans, a main power input, and communication ports (USB, RS-232, and an optional slot for network card).
The rear panel provides the necessary connections for input power, output to protected devices, and communication interfaces. It includes four Type F earthing contact outlets, a terminal output, USB and RS-232 communication ports, and slots for optional accessories like network cards.
Enstriksyon Enstalasyon
1. Plasman
- Place the UPS on a flat, stable surface.
- Ensure the environment is well-ventilated and free from excessive dust or moisture.
- Maintain at least 20 cm (8 inches) of clearance from the rear and sides of the UPS for proper airflow.
- Avoid placing the UPS near heat-emitting appliances.
2. Konekte ak pouvwa
- Connect the provided power input cable to the UPS input receptacle on the rear panel.
- Plug the other end of the power input cable into a grounded wall outlet.
- Allow the UPS to charge for at least 8 hours before initial use to ensure optimal battery performance.
3. Konekte Aparèy
- Plug your critical devices (e.g., computers, servers, network equipment) into the Type F output receptacles on the rear panel of the UPS.
- Ensure that the total load connected to the UPS does not exceed its rated capacity (2700W for this model).
- For devices requiring terminal output, connect them according to electrical safety standards.
4. Inisyal demaraj
- After connecting the UPS to AC power and allowing initial charging, press and hold the ON button on the front panel for approximately 2 seconds.
- The UPS will perform a self-test, and the LCD display will illuminate, indicating operational status.
- The UPS is now providing protected power to the connected devices.
Opere UPS la
Limen / Off
- Pou limen: Peze epi kenbe la ON bouton pou 2 segonn.
- Pou etenn: Peze epi kenbe la OFF button for 2 seconds. The UPS will shut down, and power to connected devices will cease.
Konprann LCD Display la
The LCD display provides critical information about the UPS status. Use the ANTRE epi ESC buttons to navigate through different display screens, which may include:
- Antre Voltage ak Frekans
- Sòti Voltage ak Frekans
- Nivo chaj batri
- Chaj Pousantage
- Operating Mode (Online, Battery, Bypass)
- Kòd Erè (si genyen)
Operasyon sovgad batri
Nan evènman an nan yon pouvwa outage oswa volim siyifikatiftage fluctuation, the UPS will automatically switch to battery power to provide continuous power to connected devices. An audible alarm may sound, and the LCD will indicate "Battery Mode." The duration of battery backup depends on the load connected and the battery charge level.
Lojisyèl kominikasyon
For advanced monitoring and management, install the provided communication software on a computer connected to the UPS via the USB or RS-232 port. This software allows for scheduled shutdowns, remote monitoring, and detailed event logging.
Antretyen
Swen batri
- Ensure the UPS is connected to AC power at all times to keep the batteries fully charged.
- Perform a battery self-test periodically (e.g., once every 3 months) using the UPS front panel controls or communication software to verify battery health.
- Batteries have a limited lifespan. If the battery backup time significantly decreases, contact qualified service personnel for replacement.
Netwayaj
- Dekonekte UPS la nan kouran AC a ak tout aparèy ki konekte yo anvan ou netwaye li.
- Use a soft, dry cloth to wipe the exterior of the UPS.
- Do not use liquid or aerosol cleaners, as they may damage the unit.
- Periodically clean the ventilation grilles to prevent dust buildup, which can impede airflow and cause overheating.
Depo
- If storing the UPS for an extended period, ensure the batteries are fully charged.
- Store the UPS in a cool, dry place.
- Recharge the batteries every 3 months during storage to prevent deep discharge and prolong battery life.
Depanaj
Refer to the table below for common issues and their solutions. If the problem persists, contact technical support.
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| UPS la pa limen. | Pa gen kouran AC. Low chaj batri. | Tcheke koneksyon kòd kouran an ak priz miray la. Allow UPS to charge for several hours. |
| UPS beeps continuously in normal mode. | Kondisyon Surcharge. Entèn fay. | Reduce the load by unplugging non-essential devices. Kontakte sipò teknik. |
| Tan backup kout. | Batri yo pa chaje nèt. Batteries reaching end of life. Chaj twòp. | Allow UPS to charge for 8+ hours. Contact service for battery replacement. Diminye chaj konekte a. |
| UPS is noisy. | Normal fan operation (especially under load). Fanatik obstruction. | This is normal for online UPS units. Ensure proper ventilation. Check for and clear any obstructions around fans. |
Espesifikasyon
| Karakteristik | Detay |
|---|---|
| Modèl | 10122182 |
| Kapasite | 3000 VA / 2700 W |
| Antre Voltage | 300 Vòlt (nominal) |
| Sòti Voltage | 300 Vòlt (nominal) |
| Kalite batri | Lead-Acid, AGM |
| Batri enkli | Wi |
| Sòti Sòti | 4x Type F Earthing Contact, Terminal Output |
| Faktè fòm | Tower |
| Dimansyon (L x W x H) | 41.6 x 19.6 x 34.2 cm |
| Pwa | 21 kg |
| Materyèl | Plastik |
| Ampepòk | 9 Amps |
Garanti ak sipò
The PowerWalker VFI 3000 AT UPS is covered by a manufacturer's warranty. For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official PowerWalker websit.
For technical support, service inquiries, or to report any issues, please contact your local dealer or PowerWalker customer service. Have your model number (10122182) and purchase information ready when contacting support.