IBO BETA2 25-40/180

IBO BETA2 25-40/180 Hot Water Circulation Pump User Manual

1. Entwodiksyon

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your IBO BETA2 25-40/180 Hot Water Circulation Pump. Please read this manual thoroughly before installation and retain it for future reference.

The IBO BETA2 25-40/180 circulation pump is a high-efficiency, durable, and reliable pump designed to circulate water in central heating systems, solar installations, or hot water systems. This device features 11 speed settings, allowing for parameter adaptation to various operating conditions. An electronic processor controls the pump's operation. It is equipped with a single-phase motor with a power range of 5 to 22 W. Constructed from high-quality materials, the IBO BETA2 pump ensures optimal performance under all conditions and is resistant to high temperatures. It can operate in ambient temperatures from 0 °C to 40 °C, with the device surface reaching approximately 125 °C and pumped water temperatures up to 110 °C. The pump is designed for easy installation and intuitive use, featuring an electronic display that shows current energy consumption and operating status. Additionally, the pump operates quietly (43 dB) and offers significant energy efficiency, consuming between 1/10 and 1/3 of the energy compared to traditional pumps. The device has a 1 ½ inch diameter connection (180 mm distance between connections). It operates with a capacity of up to 50 liters per minute and can lift water up to a height of 4 meters. The Beta 2 25-40/180 pump includes a power cable and screw fittings.

2. Enstriksyon Sekirite

Always observe the following safety precautions to prevent injury and damage to the pump or property:

  • Sekirite elektrik: Ensure the power supply matches the pump's specifications (230V). Disconnect power before any installation, maintenance, or repair work. All electrical connections must be performed by a qualified electrician and comply with local regulations.
  • Tanperati dlo: The pump handles liquid temperatures from +2 °C to +110 °C. Ensure the system's operating temperature remains within this range.
  • Tanperati anbyen: Operate the pump in ambient temperatures between 0 °C and 40 °C.
  • Presyon: Do not exceed the maximum system pressure of 1 MPa.
  • Enstalasyon: Install the pump in a dry, well-ventilated area, protected from frost and direct sunlight. Ensure proper ventilation to prevent overheating.
  • Manyen: The pump is heavy (2.92 kg). Use appropriate lifting techniques or assistance during installation.
  • Timoun ak Pèsonèl ki pa Otorize: Keep children and unauthorized persons away from the pump during operation and maintenance.

3. Konpozan souview

The IBO BETA2 25-40/180 circulation pump package typically includes the following items:

  • IBO BETA2 25-40/180 Circulation Pump Unit
  • Pouvwa kab
  • Set of Screw Fittings (for pipe connection)
  • Manyèl Itilizatè (dokiman sa a)
IBO BETA2 25-40/180 Hot Water Circulation Pump with power cable

Figi 3.1: IBO BETA2 25-40/180 Hot Water Circulation Pump. This image displays the IBO BETA2 25-40/180 hot water circulation pump. The pump is black, cylindrical in shape with two threaded pipe connections. An electronic display panel is visible on the front, showing 'ECO' and numerical readings, along with two green indicator lights and buttons labeled 'PP1', 'PP2', 'CP1', 'CP2'. A black power cable with a standard European plug is shown detached from the pump, indicating it's included for connection.

4. Enstalasyon ak Enstalasyon

The IBO BETA2 25-40/180 pump is designed for easy installation. However, professional installation by a qualified technician is recommended to ensure proper functioning and compliance with all local codes and regulations.

4.1 Chèk Pre-Enstalasyon

  • Verify that the installation site meets the ambient temperature requirements (0 °C to 40 °C).
  • Ensure the power supply is 230V and adequately protected.
  • Confirm that the pipe connections are clean and free of debris.

4.2 Monte ponp lan

  1. Choose a suitable location in the heating or hot water system where the pump can be easily accessed for maintenance.
  2. Ensure the pump is mounted horizontally with the motor shaft in a horizontal position to ensure proper lubrication and cooling.
  3. Use the provided screw fittings to connect the pump to the system piping. Ensure a tight, leak-free connection. The connection diameter is 1 ½ inches, with a distance of 180 mm between connections.

4.3 Koneksyon elektrik

  1. Ensure the main power supply is switched off before making any electrical connections.
  2. Connect the provided power cable to the pump's electrical terminal block according to the wiring diagram (refer to the diagram on the pump or in the packaging if available).
  3. Connect the other end of the power cable to a grounded 230V power outlet.
  4. Verifye tout koneksyon an sekirite epi byen izole.

4.4 Ranpli ak Vantilasyon Sistèm

  1. After installation, fill the heating or hot water system with water.
  2. Vent the system thoroughly to remove any trapped air. Air in the system can cause noise, reduce pump efficiency, and lead to damage.

5. Operasyon Enstriksyon

The IBO BETA2 25-40/180 pump features an electronic control system for intuitive operation.

5.1 Premye kòmansman

  1. After ensuring the system is filled and vented, switch on the main power supply to the pump.
  2. The electronic display will illuminate, showing the current operating status and energy consumption.

5.2 Ajisteman Paramèt Vitès yo

The pump offers 11 speed settings to adapt to various system requirements. Use the control buttons on the display panel (e.g., PP1, PP2, CP1, CP2, ECO) to cycle through the available modes and speeds. The display will indicate the selected setting and corresponding energy consumption.

  • Mòd ECO: Pou operasyon ki ekonomize enèji.
  • PP Modes: Proportional pressure modes, where pump head adjusts proportionally to flow rate.
  • CP Modes: Constant pressure modes, maintaining a constant differential pressure.

Consult your heating system's requirements or a qualified technician to determine the optimal setting for your application.

5.3 Operasyon Siveyans

The electronic display provides real-time feedback on:

  • Current energy consumption (in Watts)
  • Selected operating mode/speed
  • Any error codes (if applicable)

The pump operates quietly, with a sound pressure level of 43 dB.

6. Antretyen

Regular maintenance ensures the longevity and efficient operation of your IBO BETA2 25-40/180 pump.

6.1 General Checks (Monthly)

  • Visually inspect the pump for any signs of leaks, corrosion, or damage.
  • Listen for unusual noises during operation, which could indicate air in the system or mechanical issues.
  • Check the electronic display for any error messages.

6.2 System Water Quality

Maintain good water quality in your heating system. Poor water quality can lead to scale buildup, corrosion, and reduced pump performance. Consider using appropriate system inhibitors if recommended for your heating system type.

6.3 Netwayaj

Keep the exterior of the pump clean and free from dust and debris to ensure proper heat dissipation.

6.4 Sèvis Pwofesyonèl (Chak ane)

It is recommended to have the pump and heating system inspected by a qualified technician annually to ensure optimal performance and identify any potential issues early.

NAN. Depanaj

This section addresses common issues you might encounter with your IBO BETA2 25-40/180 pump. For complex problems, contact a qualified technician.

PwoblèmKòz posibSolisyon
Ponp pa kòmansePa gen ekipman pou pouvwa
Kònen fuse / brekè brekè
Bloke motè
Check power connection and supply
Check and replace fuse/reset breaker
Disconnect power, check for obstructions in the impeller (professional service recommended)
Ponp kouri men pa gen sikilasyon dloLè nan sistèm lan
Tiyo fèmen
Blokaj roue
Vent the system thoroughly
Open all necessary valves in the system
Disconnect power, check for obstructions (professional service recommended)
Ponp fè bwiLè nan sistèm lan
Cavitation (insufficient system pressure)
Montaj ki lach
Vant sistèm nan
Check system pressure and increase if necessary
Ensure pump is securely mounted
Ponp kouleKoneksyon ki lach
Fok ki domaje
Tighten pipe connections
Contact a qualified technician for seal replacement
Electronic display shows error codeSpecific internal faultRefer to the pump's specific error code list (if available in packaging) or contact technical support.

8. Espesifikasyon teknik

ParamètValè
ModèlBETA2 25-40/180
ManifaktiRöhtenbach
Pouvwa motè5 - 22 W
Voltage230 V (+6% / -10%)
Nivo SekiriteIP42
Motè D 'GwoupH
Maksimòm Leve Wotè4 mèt
Pousantaj maksimòm koule50 lit pou chak minit
Imidite relatif95%
Maksimòm Presyon Sistèm1 MPa
Pumped Liquid Temperature+2 °C a +110 °C
Tanperati anbyen0 °C a 40 °C
Nivo Presyon Son43 dB (A)
Dyamèt koneksyon1 ½ inches (180 mm between connections)
Dimansyon pwodwi (L x W x H)21 x 18 x 11 cm
Pwa atik2.92 kg
MateryèlJete Iron
KoulèNwa
Kalite sous pouvwaKab elektrik

9. Enfòmasyon sou Garanti

Specific warranty details for the IBO BETA2 25-40/180 pump are not provided in the available product information. Please refer to your purchase documentation or contact your retailer for warranty terms and conditions.

10. Sipò ak Kontak

For technical assistance, spare parts, or service inquiries, please contact the retailer from whom you purchased the IBO BETA2 25-40/180 pump. Keep your purchase receipt and product model information readily available when contacting support.

Manifakti: Röhtenbach

© 2024 IBO. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.