1. Entwodiksyon
This manual provides essential information for the safe and effective use of your JIAYIN JYPC-3 Series Electromagnetic Plunger Pump. Please read these instructions thoroughly before installation, operation, or maintenance to ensure proper function and to prevent damage or injury. Keep this manual for future reference.
2. Pwodwi souview
The JIAYIN JYPC-3 is an original plunger-type electromagnetic pump designed for various applications, including hot water dispensers. It operates on AC 110V-120V power, delivering a flow rate of 700cc/min with a working pressure up to 2.5 bar. Its robust design ensures reliable performance with water or non-corrosive liquids.
Karakteristik kle:
- Designed for AC 110V-120V, 60Hz power supply.
- 25W power consumption.
- Flow rate of 700 ±10% cc/min.
- Suitable for water or non-corrosive liquids.
- Operating ambient temperature: up to 70℃ (158°F).
- Operating medium temperature: up to 60℃ (140°F).
- Plunger type mechanism for efficient suction.

Figi 2.1: Devan view of the JIAYIN JYPC-3 electromagnetic plunger pump, showing the main body, electrical terminals, and inlet/outlet ports.

Figi 2.2: Angle view of the JIAYIN JYPC-3 pump, highlighting the plunger mechanism and compact design.
3. Espesifikasyon teknik
The following table details the technical specifications of the JIAYIN JYPC-3 electromagnetic plunger pump:
| Paramèt | Valè |
|---|---|
| Modèl | JYPC-3 |
| Mak | JIAYIN |
| Kalite | Electromagnetic Plunger Pump |
| Voltage | AC 110V-120V |
| Frekans | 60Hz |
| Pouvwa | 25W |
| Pousantaj koule | 700 ±10% cc/min |
| Travay presyon | 0-2.5 bar |
| Travay mwayen | Water or non-corrosive liquid |
| Tanperati anbyen | Up to 70℃ (158°F) |
| Tanperati Mwayen | Up to 60℃ (140°F) |
| Pump Shaft Position | Orizontal |
| Pwa nèt | 137 ±5g (approx. 5.2 ounces) |
| Dimansyon pwodwi | Apeprè. 3.84 x 1.5 x 1.5 pous (97.5 x 38 x 38 mm) |
| Materyèl | Plastik |

Figure 3.1: Detailed dimensional drawing of the JIAYIN JYPC-3 pump, showing key measurements in millimeters and inches.

Figure 3.2: Technical parameters and performance graphs for the JIAYIN JYPC-3 pump, illustrating flow/pressure, flow time, and temperature/time relationships.
4. Enfòmasyon sou Sekirite
Adhering to safety precautions is crucial for preventing injury and damage to the pump. Please observe the following:
- Sekirite elektrik: Asire w ke ekipman pou pouvwa a koresponn ak vòltaj ponp lan.tage (AC 110V-120V). Disconnect power before installation, maintenance, or troubleshooting. All electrical connections should be performed by a qualified individual and comply with local electrical codes.
- Likid konpatibilite: Use only water or non-corrosive liquids. Using corrosive chemicals can damage the pump and void the warranty.
- Limit Tanperati: Do not exceed the specified ambient (70℃/158°F) or medium (60℃/140°F) temperature limits. Overheating can lead to pump failure.
- Enstalasyon apwopriye: Install the pump in a horizontal position as specified. Incorrect orientation may affect performance and longevity.
- Evite kouri sèk: Do not operate the pump without liquid. Dry running can cause severe damage to internal components.
- Koneksyon an sekirite: Ensure all tubing and electrical connections are secure to prevent leaks or electrical hazards.
- Timoun ak bèt kay: Keep the pump and its associated components out of reach of children and pets.
5. Enstalasyon ak Enstalasyon
Follow these steps for proper installation of your JYPC-3 pump:
- Debake: Carefully remove the pump from its packaging. Inspect for any visible damage.
- Montaj: Mount the pump securely in a horizontal position. Ensure there is adequate space for tubing connections and ventilation.
- Koneksyon tib:
- Connect the inlet tubing to the designated inlet port. The product description specifies a flow test method using a 13.8-inch silicon tube with an outer diameter of 0.31 inches and an inner diameter of 0.16 inches. Ensure your tubing is compatible and securely fastened to prevent leaks.
- Connect the outlet tubing to the designated outlet port.
- Ensure tubing is not kinked or obstructed.
- Koneksyon elektrik:
- Ensure the power source is disconnected before making any electrical connections.
- Connect the pump's electrical terminals to an AC 110V-120V, 60Hz power supply. Refer to the wiring diagram of your specific application for correct polarity if applicable.
- Verify all electrical connections are tight and insulated to prevent short circuits or electrical hazards.
- Priming (si sa nesesè): Depending on your application, the pump may require priming to ensure it is filled with liquid before initial operation. Consult your system's specific requirements.

Figi 5.1: View of the JIAYIN JYPC-3 pump showing the electrical terminals for power connection.

Figure 5.2: The JIAYIN JYPC-3 pump with protective red caps on the inlet and outlet ports, indicating proper handling before tubing installation.
6. Operasyon Enstriksyon
Once the pump is properly installed and all connections are secure, you can begin operation:
- Verify Liquid Supply: Ensure there is an adequate supply of the intended liquid (water or non-corrosive) available at the pump's inlet. Never operate the pump dry.
- Pouvwa sou: Connect the pump to the AC 110V-120V, 60Hz power supply. The pump should begin to operate, drawing liquid through the inlet and expelling it through the outlet.
- Siveye pèfòmans: Observe the pump during initial operation. Check for any unusual noises, vibrations, or leaks. Verify that liquid is flowing as expected.
- Kontwòl koule: The pump has a flow control range of ±10%. If your system requires precise flow, integrate appropriate external flow control mechanisms.
- Pouvwa Off: To stop the pump, disconnect it from the power supply.
7. Antretyen
Regular maintenance helps ensure the longevity and optimal performance of your JYPC-3 pump:
- Enspeksyon regilye: Periodically inspect the pump and all connections for signs of wear, damage, or leaks.
- Lapwòpte: Ensure the pump's exterior is kept clean. Prevent dust and debris from accumulating around the motor housing, which could impede cooling.
- Anpeche blokaj: If the pump is used with liquids that may contain particulates, consider installing an inline filter on the inlet side to prevent clogging of the pump''s internal mechanisms.
- Depo: If the pump is to be stored for an extended period, drain any remaining liquid and store it in a dry, clean environment.
- Pa gen okenn pati itilizatè yo ka fè sèvis: The internal components of the pump are not designed for user servicing. Do not attempt to disassemble the pump, as this may cause damage and void the warranty.
NAN. Depanaj
If you encounter issues with your JYPC-3 pump, refer to the following troubleshooting guide:
| Pwoblèm | Kòz posib | Solisyon |
|---|---|---|
| Ponp pa kòmanse | Pa gen ekipman pou pouvwa Incorrect voltage Koneksyon elektrik ki lach | Tcheke priz kouran an ak disjonktè a Verify power supply is AC 110V-120V Sekirize tout koneksyon elektrik |
| Pump runs but no liquid flows | No liquid in supply Inlet tubing kinked or blocked Pump not primed (airlock) Entèn blokaj | Ensure liquid supply is available Inspect and clear inlet tubing Prime the pump according to system requirements Check for foreign objects (if accessible without disassembly) |
| Redwi pousantaj koule | Partial blockage in tubing or pump Air leak in inlet line Worn components (after extended use) | Inspect and clear tubing/inlet Tighten all inlet connections Consider pump replacement if wear is suspected |
| Bri oswa vibrasyon etranj | Kouri sèk Montaj ki lach Internal obstruction or damage | Ensure continuous liquid supply Sere boulon vis aliye yo If noise persists, discontinue use and contact support |
| Liquid leaks | Loose tubing connections Damaged tubing or pump housing | Tighten all tubing connections Inspect tubing and pump for cracks; replace damaged components |
Si pwoblèm nan pèsiste apre ou fin eseye solisyon sa yo, tanpri kontakte sèvis kliyan.
9. Garanti ak Sipò Kliyan
For warranty information or technical assistance, please contact the retailer or manufacturer directly. Provide your product model (JYPC-3) and purchase date when seeking support. Do not attempt to repair the pump yourself, as this may void any applicable warranty.